Plan Review Details - Permit 99091124
Plan Review Stops For Permit 99091124
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2000-08-19 Cont ID  
Sent By lmartine Date 2000-08-19 Time 12:38 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 1999-12-02 Cont ID  
Sent By hpiskura Date 1999-12-02 Time 16:43 Rev Time 0.00
Received By hpiskura Date 1999-12-02 Time 16:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 1999-11-05 Cont ID  
Sent By hpiskura Date 1999-11-05 Time 08:43 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00PLAN REVIEW COMMENTS ATTACHED TO PLANS

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-10-03 Cont ID  
Sent By dpalmer Date 2000-10-03 Time 07:48 Rev Time 0.00
Received By dpalmer Date 2000-10-03 Time 07:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-10-21 Cont ID  
Sent By jleahy Date 1999-10-21 Time 14:40 Rev Time 1.00
Received By jleahy Date 1999-10-21 Time 14:40 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 1999-12-13 Cont ID  
Sent By hpiskura Date 1999-12-13 Time 12:17 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED ON PUBLIX SITE PERMIT

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-11-03 Cont ID  
Sent By rturnque Date 1999-11-03 Time 14:48 Rev Time 0.15
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-10-20 Cont ID  
Sent By ndenmark Date 1999-10-20 Time 13:33 Rev Time 0.50
Received By ndenmark Date 1999-10-20 Time 13:33 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 1) FAN SHUT DOWN REQUIRED FOR AHU 1,2&3
 BY DUCT SMOKE DETECTOR PER 1997 SMC 406
 2) NOTIFICATION BY HORN AND STROBE OF
 FAN SHUT DOWN REQUIRED BY NFPA 4-4.4.3
 3) ADDITIONAL MECHANICAL PERMITS REQUIRE
 FOR FUEL AND WALK IN COOLER

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-09-01 Cont ID  
Sent By tlarge Date 2000-09-01 Time 18:01 Rev Time 0.75
Received By pschmitz Date 2000-09-01 Time 17:42 Sent To  
Notes
2001-01-08 00:00:001)TWO WAY CLEANOUTS REQD.ENTERING AND
 LEAVING EACH TANK.SEE 750 GAL RECLAIM
 TANK.SPC SEC.710.4.
  
 2)SIZE OF TANKS DO NOT MATCH APPROVED
 PLANS.SEE RECLAIM TANK AND OIL/SAND INT.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 3)VENT SHALL RISE 6" ABOVE FLOOD LEVEL
 OF INT.PRIOR TO OFFSETTING HORIZ.SPC
 906.2.1.
  
 4)SUBMIT FULL SIZE BLUEPRINTS FOR REVIEW
 THAT ARE SIGNED,DATED AND SEALED BY THE
 DESIGN PROFESSIONAL OF RECORD.SPC SEC.
 104.2.3.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-11-27 Cont ID  
Sent By tlarge Date 1999-11-27 Time 11:23 Rev Time 1.00
Received By tlarge Date 1999-11-27 Time 11:23 Sent To  
Notes
2001-01-08 00:00:00******************PROVISO***************
 SHOP DRAWINGS REQD.FOR AIR/WATER & OIL
 SEPARATOR AT CAR WASH.

Review Stop P PLUMBING
Rev No 1 Status F Date 1999-10-19 Cont ID  
Sent By tlarge Date 1999-10-19 Time 15:52 Rev Time 4.75
Received By pschmitz Date 1999-10-19 Time 15:52 Sent To  
Notes
2001-01-08 00:00:00JOB SPECS.-PG.155-SEC.3.01(C)-HANGERS
 FOR COPPER TUBE 2" & LARGER SHALL COMPLY
 W/SPC SEC.310.3.4.
  
 CONTACT RODNEY COMPO AT CITY OF W.P.B.
 REGIONAL WASTEWATER TREATMENT PLANT FOR
 SIZE REQS.OF GREASE AND SAND/OIL INTER-
 CEPTORS.(561)835-7423.
  
 SHT.P-1-VENTS THRU ROOF CANNOT BE
 INCREASED PER SPC 905.2.(ONLY USED FOR
 FROST CLOSURE.)
  
 MULTIPLE CONDENSATE DRAINS SHALL BE
 SIZED PER STD.MECH.CODE SEC.304.8.4.
  
 RECEPTACLES FOR INDIRECT WASTES SHALL
 BE FLOOR DRAINS OR FLOOR SINKS PER SPC
 SEC.807.
  
 CLEARLY SHOW TERMINATION POINT OF TRENCH
 DRAIN AT CAR WASH.COMPLY W/SPC SEC.104.2
 1004.5,1004.6.
  
 VENTING FOR SANITARY SYSTEM SHALL COMPLY
 W/SPC SEC.920.2.(NOTE CAPACITY OF 1 1/2"
 VENT.)
  
 SHT.4 OF 8 SHOWS 2"WATER SERVICE AND SHT
 P2 SHOWS 1 1/2".CLARIFY.SPC 104.2.1.
  
 SIZE THE COOLER DRAINS ON SHT.P1.COMPLY
 W/SPC SEC.713.3,714.2.
  
 INDIRECT WASTES SHALL BE TRAPPED AND
 COMPLY W/SPC SEC.805.1.1,805.1.2.
  
 SUBMIT RISER DIAGRAMS FOR AIR/WATER
 SYSTEMS.SPC 104.2.1.
  
 SUBMIT MANUF.DATA FOR GREASE/OIL INTER.
 104.2.2.
  
 DRAINS FROM SODA FOUNTAINS SHALL DRAIN
 TO GREASY WASTE SYSTEM.SPC 1004.1
  
 HOT WATER TO RESTROOMS SHALL BE 110
 DEGREES MAX PER FLA.ENERGY CODE SEC.
 412.1 ABCD.2.3.2.

Review Stop Z ZONING
Rev No 1 Status P Date 1999-12-13 Cont ID  
Sent By hpiskura Date 1999-12-13 Time 12:15 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***