| Plan Review Stops For Permit 99090784 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
1999-11-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
1999-11-02 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BUILD REVIEW:WSTAPLES |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
1999-10-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-10-18 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
1999-09-27 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
1999-09-27 |
Time |
08:14 |
Rev Time |
0.25 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PRODUCT APPROVALS SUBMITTED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
1999-11-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-10-18 |
Time |
13:43 |
Rev Time |
99.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
1999-10-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
1999-10-26 |
Time |
13:24 |
Rev Time |
2.00 |
| Received By |
jleahy |
Date |
1999-10-26 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)AC AND ELECTRICAL SERVICE IN SAME | | | SPACE SEE 110-16 | | | | | | 2)SHOW ALL WORK NEW AND EXISTING. | | | | | | 3)SHOW ALL BRANCH CIRCUIT NUMBERS ON | | | PLAN(HOW MANY OUTLETS ON A CKT.) | | | | | | 4)NO FAULT CURRENT CALCULATION 110-10 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
1999-11-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
1999-10-07 |
Time |
12:47 |
Rev Time |
0.45 |
| Received By |
jwitmer |
Date |
1999-10-07 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)LOAD CALCULKATION SHOWN IS FOR | | | RESIDENTIAL NOT COMMERCIAL | | | | | | 2)LOAD CALC. SHALL SHOW CONTINUOUS | | | LOAD FACTOR ON LIGHTING PER 220-10B | | | | | | 3)OUTLET SPACING IS NOT TO LOCAL CODE | | | IN OFFICE AREA 12' ON CENTER ALL | | | OTHER AREAS 20' ON CENTER ! | | | | | | 4)TRACK LIGHTING IS NOT SHOWN ON LOAD | | | CALCULATION410-102 | | | | | | 5)NO BRANCH CIRCUIT NUMBERS SHOWN ON | | | PLANS | | | | | | 6)NO PANEL SCHEDULES SHOWN | | | | | | 7)SUBMIT AIC CALCULKATION FOR SERVICE | | | AND PANELS110-9,10 | | | | | | 8)WHAT TYPE OF OCCUPANCY ARE THESE? | | | OFFICE SPACES REQUIRE 3.5 VA PER SQ. | | | FT. FOR LIGHTING PLUS CONTINOUS FAC. | | | | | | 9)SERVICE LOCATION NOT SHOWN!!!!!!!!! | | | | | | 10) A/C COMPRESSORS NOT SHOWN, ALSO NEED | | | GFI OUTLETS FOR SERVICE OF A/CS | | | | | | | | | APPROVED BY J LEAHY SEE PLANS FOR | | | PROVISO. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
1999-11-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
1999-11-02 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
1999-11-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-10-18 |
Time |
13:44 |
Rev Time |
99.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | STORM & TRASH REJECT |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
1999-10-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-10-18 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
1999-10-12 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-10-12 |
Time |
07:15 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
1999-10-12 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO MECHANICAL TO REVIEW; SUBMIT PLANS AT | | | TIME OF MECHANICAL PERMIT APPLICATION | | | FOR REVIEW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
1999-12-07 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-12-07 |
Time |
08:34 |
Rev Time |
1.50 |
| Received By |
tlarge |
Date |
1999-12-04 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
1999-10-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-10-23 |
Time |
09:00 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | | | | | | | | | | | | | | | | | | | (3) 2ND FLOOR TENANT SPACE, SHOW | | | FACILITIES FOR FRONT SPACE,PLAN SHOWS 3 | | | SEPERATE SPACES.FACILITIES IN 2 UNITS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-10-23 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-10-09 |
Time |
09:47 |
Rev Time |
0.65 |
| Received By |
pschmitz |
Date |
1999-10-09 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT SANITARY AND WATER RISERS FOR NEW | | | TOILET ROOM PER SPC 104.2.1. | | | | | | SUBMIT DETAILS FOR HANDICAP FIXTURES, | | | DISPENSERS,AND CONTROLS.COMPLY W/FACBC. | | | COMPLIED WITH 10-23-99 PES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
1999-12-15 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-12-15 |
Time |
10:54 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
1999-11-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
1999-11-02 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|