Plan Review Details - Permit 99090501
| Plan Review Stops For Permit 99090501 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
1999-11-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
1999-11-05 |
Time |
15:36 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
1999-11-05 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
1999-11-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-10-07 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
fknapp |
Date |
1999-10-07 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************DENIED****************** | | | | | | 1)NOTE:AS PER ART:220-3-D-1 ADDITIONS | | | OVER 500 SQ.FT. NEED TO HAVE LOAD CALCS. | | | 2)NOTE;AS PER 250-24-C-1,2,3 SEPARTE | | | DISC.MEANS IS REQ`D IF YOU MEET THAT | | | CODE ART.IF BATH IS INSTALLED THEN BATH | | | REQ`D CIRCUT AND RECEPT.AS PER ART; | | | 210-52D | | | | | | | | | PLEASE PROVIDE EXISTING RISER DIAGRAM, | | | SHOWING SIZE OF SERVICE,WIRE,AND LOADS. | | | IF DETACHED GARAGE MEETS THE REQ`MENTS | | | OF 250-24C THEN SHOW THE MEANS OF DISC. | | | (PANEL) FEED,PIPE SIZE, WIRE,GROUNDING | | | ELECTRODE SYSTEM, ETC. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
1999-10-07 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-11-10 |
Time |
15:06 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
1999-10-07 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT A/C PLAN WITH A/C APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
1999-11-08 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-11-08 |
Time |
07:12 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
1999-11-08 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO:GAS DRAWINGS AND PERMIT REQD. | | | PRIOR TO BEGINNING WORK. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-10-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-10-05 |
Time |
14:12 |
Rev Time |
0.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
1999-11-10 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-11-10 |
Time |
14:45 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
1999-11-10 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************PROVISO******************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE SITE SPECIFIC PRODUCT APPROVAL | | | FOR CUSTOM GARAGE DOORS. | | | 2)PROVIDE PRODUCT APPROVAL FOR SIDE DOOR | | | OF GARAGE | | | SUBMIT PRIOR TO INSTALLATION | | | 3)PROVIDE STORM PANEL INSTALLATION | | | SCHEDULE AND KEY PLAN WITH SPECIFIC | | | MOUNTING AND ANCHORS TO BE USED | | | UNDER SEPERATE PERMIT |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
1999-11-10 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-10-07 |
Time |
06:45 |
Rev Time |
3.00 |
| Received By |
fknapp |
Date |
1999-10-07 |
Time |
07:29 |
Sent To |
M |
|
| Notes |
| 2001-01-08 00:00:00 | DENIED: | | | SBC 104.2.2 | | | 1)PROVIDE ARCHITECT RAISED SEAL ON ALL | | | PLANS. | | | | | | 2)CORRECT PLANS TO MEET ZONING APPROVAL | | | | | | 3)PROVIDE 2 CURRENT COPIES OF PRODUCT | | | APPROVAL FOR THE FOLLOWING: | | | WINDOWS | | | GARAGE DOOR | | | ROOF COVERING | | | STORM PANELS WITH INSTALLATION SCHEDU- | | | LE & KEY PLAN WITH SPECIFIC MOUNTING | | | & ANCHORS TO BE USED | | | | | | 4)PROVIDE OWNER SIGNATURE ON ENERGY | | | CALCULATION | | | | | | 5)PROVIDE ROOF SHEATHING NAILING ZONES | | | COMPLYING WITH SBC 2306.1 | | | | | | 6)PROVIDE SPECIFIC WINDOW AND DOOR BUCK | | | CONNECTIONS FOR WIND LOAD RESISTANCE | | | SBC 1606 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-09-20 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-09-20 |
Time |
09:21 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|