| Plan Review Stops For Permit 99090467 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-01-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-01-07 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
1999-10-05 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-10-05 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2001-03-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-11 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-11 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-11-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-16 |
Time |
21:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-16 |
Time |
21:28 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************** PROVISO ************* | | | | | | 1)NOTE: PLEASE PROVIDE INFORMATION ON | | | ORIGINAL PROVISO THAT WAS SET FORTH BY | | | JAKE LEAHY (CHIEF ELEC. INSP.) ON REVIEW | | | DATED 10/6/99. PLEASE SUBMIT REVISED | | | MAIN POWER LINE DIAGRAM BEFORE FINAL IS | | | CALLED IN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-04-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-04-19 |
Time |
20:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-04-19 |
Time |
20:39 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ORIG NOTE ADDRESSED ON PERMIT # 99090467 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-10-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
1999-10-06 |
Time |
15:50 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
1999-10-06 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | EMERGENCY FEED FROM GENERATOR TO HAVE A | | | DISCONNECT GROUPED WITH OTHER MAINS PER | | | 230-72B |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2000-01-19 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
1999-10-12 |
Time |
10:13 |
Rev Time |
1.25 |
| Received By |
dlauderm |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PASSED WITH PROVISOS:TS (659-8040) | | | WATER AND SANITARY:ONCERNING STORMWATER | | | 1.DRAWINGS MUST BE THE ONES LAST REVISED | | | AND APPROVED ON 11/19/99 STAMPED FORTA- | | | HEALTH DEPARTMENT 11-23-99 WITH 2-2"ALED | | | METERS AND A 4" PFL, AND A 6" LATERAL, | | | ALL TO BE CONTRACTOR INSTALLED (ALL0); | | | SHEETS, 6 OF 6).PPROVED THRU UTILITIES | | | 2.ADDITIONALLY IF THE 11-23-99 REVISIONS | | | DO NOT SHOW IT A CLEAN-OUT MUST BE | | | PLACED AT THE BACK OF SIDEWALK, SEE CITY | | | DETAIL ON SHEET 5 OF 6. | | | 3.BACKFLOW PREVENTER LOCATION ON SHEETE- | | | FS-1 IS WRONG.BACKFLOW PREVENTER BY | | | (DCDA) WILL BE LOCATED AT BACK OF WALK. | | | STORMWATER: | | | PLAN SHEET 2 OF 6 AND CALCULATIONS | | | SUBMITTED WITH 10-20-99 REVISED DATE OK. | | | STREETS: | | | 1.STOP SIGN ON SOUTHWEST EXIT IS TO BE | | | AT BACK OF SIDEWALK, NOT AT CURB (SEE | | | SHEET 2 OF 6) | | | 2.STOP SIGN ON NORTHEAST EXIT IS TO BE | | | AT BACK OF SIDEWALK, NOT IN DRIVEWAY | | | RAMP (SEE SHEET 2 OF 6).THE PARKING | | | LOT LIGHT ON SHEET SP-1 MAY INTERFERE | | | WITH THIS STOP SIGN, PERHAPS THE STOP | | | SIGN CAN BE MOUNTED TO THE LIGHT POLE, | | | BUT THE LIGHT POLE SHOULD NOT BE THAT | | | CLOSE TO THE DRIVEWAY. | | | 3.BOTH DRIVEWAY RAMPS ARE TO BE CONCRETE | | | AND TO THE CITY DETAILS (SEE ATTACHED). | | | 4.I CAN NOT FIND ON THE DRAWINGS A | | | STATEMENT THAT THE EXISTING DRIVEWAYS | | | WILL BE REMOVED BY THE CONTRATOR, THEY | | | WILL BE REMOVED BY THE CONTRACTOR AND | | | REPLACED WITH CURBS THAT MATCH THE | | | EXISTING. | | | 5.LANDSCAPING (PALM TREES) CAN NOT BE | | | PLACED OVER THE WATER MAIN ON FLAGLER, | | | REMOVE THEM (SEE SHEET 1/4 BY | | | ENVIRONMENTAL DESIGN GROUP). | | | 6. IT IS MANDATORY THAT PLANTS BE PLACED | | | AROUND THE BACKFLOW PREVENTERS SHOWN ON | | | SHEET 2 OR 6 BY SIMMONS AND WHITE. | | | 7. SHEET E-1 DOES NOT SHOW THE TWO POLE | | | MOUNTED PARKING LOT LIGHTS SHOWN ON | | | SHEET SP-1 NEXT TO EACH DRIVEWAY. | | | DUMPSTER ENCLOSURE: | | | 1.OK, EXCEPT, THE PLUMBING PLAN DOES NOT | | | SHOW THE WATER LINE TO THE DUMPSTER AS | | | SHOWN ON PAGE SP-2 AND REFERRING TO THE | | | PLUMBING PLAN P-2, 3 OR 4. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-11-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-21 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-21 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-04-27 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-04-27 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APP'D ON PLAN 9/30/99 W/PROVISO |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-11-30 |
Time |
14:07 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-11-30 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-09-27 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-09-27 |
Time |
11:07 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
1999-09-27 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | PROVIDE MINIMUM 18" CLEARANCE UNDER ROOF | | | STANDS FOR MECHANICAL EQUIPMENT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2000-11-04 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-11-04 |
Time |
09:41 |
Rev Time |
0.65 |
| Received By |
tlarge |
Date |
2000-11-04 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************PROVISO****************** | | | MANEUVERING CLEARANCES AT DOOR FOR | | | TOILET ROOM #102 SHALL COMPLY W/FACBC | | | SEC.4.13.6 AND FIG.25(B). | | | | | | CALL IF YOU HAVE QUESTIONS. | | | 561-659-8096,EXT.8377. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-04-04 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-04-04 |
Time |
18:42 |
Rev Time |
1.50 |
| Received By |
tlarge |
Date |
2000-04-04 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************PROVISO***************** | | | DRINKING FOUNTAIN SHALL COMPLY W/FACBC | | | SEC.4.1.3.(10)(A). |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-01-20 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-01-20 |
Time |
08:14 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
2000-01-20 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | THE REQD.NUMBER OF SANITARY FACILITIES | | | FOR THE OCCUPANCY LOAD SHALL COMPLY W/ | | | TABLE 407 OF SPC.SEE SPC SEC.407.1.3. | | | | | | FLOOR DRAINS ARE REQD.INTHE TOILET ROOMS | | | PER SPC SEC.409.4.1.1(SEE EXCEPTION). | | | | | | ALL COMMON AND PUBLIC AREA TOILET ROOMS | | | SHALL BE FULLY ACCESSIBLE PER FACBC SEC. | | | 4.1.3(11). | | | | | | DRINKING FOUNTAIN SHALL COMPLY W/FACBC | | | SEC.4.1.3.(10)(A). | | | | | | WATER PIPING TO HOSE BIBB AT DUMPSTER | | | SHALL BE SHOWN ON THE PLBG.PLAN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
1999-11-18 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-11-18 |
Time |
17:15 |
Rev Time |
1.50 |
| Received By |
tlarge |
Date |
1999-11-18 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SECONDARY DRAINAGE SHALL COMPLY W/TABLE | | | A101.2(MIN.SIZE SCUPPER SHALL BE 6 X 12. | | | | | | THE REQD.NUMBER OF SANITARY FACILITIES | | | FOR THE OCCUPANT LOAD SHALL COMPLY W/ | | | TABLE 407 OF SPC. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
1999-10-07 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-10-07 |
Time |
12:00 |
Rev Time |
1.50 |
| Received By |
tlarge |
Date |
1999-10-07 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | WALLS IN TOILET ROOMS SHALL BE NON- | | | ABSORBENT TO A HEIGHT OF 4'PER SBC SEC. | | | 1204.2. | | | | | | SUBMIT OCCUPANT LOAD PER TABLE 407 OF | | | SPC. | | | | | | FLOOR DAINS ARE REQD.IN THE TOILET ROOMS | | | PER SPC SEC.409.4.1.1. | | | | | | SINK IN LOUNGE SHALL COMPLY W/FACBC SEC. | | | 4.24.1-4.24.7. | | | | | | SECONDARY DRAINAGE FOR ROOF SHALL COMPLY | | | W/SPC TABLE A101.2. | | | | | | SUBMIT STORM DRAINAGE RISER FOR REVIEW. | | | SPC 104.2.1. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-01-07 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-01-07 |
Time |
15:10 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|