Plan Review Details - Permit 99090467
Plan Review Stops For Permit 99090467
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-01-07 Cont ID  
Sent By lmartine Date 2000-01-07 Time 12:34 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 1999-10-05 Cont ID  
Sent By hpiskura Date 1999-10-05 Time 13:32 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-03-11 Cont ID  
Sent By dpalmer Date 2001-03-11 Time 09:53 Rev Time 0.00
Received By dpalmer Date 2001-03-11 Time 09:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-11-16 Cont ID  
Sent By dpalmer Date 2000-11-16 Time 21:28 Rev Time 0.00
Received By dpalmer Date 2000-11-16 Time 21:28 Sent To  
Notes
2001-01-08 00:00:00****************** PROVISO *************
  
 1)NOTE: PLEASE PROVIDE INFORMATION ON
 ORIGINAL PROVISO THAT WAS SET FORTH BY
 JAKE LEAHY (CHIEF ELEC. INSP.) ON REVIEW
 DATED 10/6/99. PLEASE SUBMIT REVISED
 MAIN POWER LINE DIAGRAM BEFORE FINAL IS
 CALLED IN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-04-19 Cont ID  
Sent By dpalmer Date 2000-04-19 Time 20:39 Rev Time 0.00
Received By dpalmer Date 2000-04-19 Time 20:39 Sent To  
Notes
2001-01-08 00:00:00ORIG NOTE ADDRESSED ON PERMIT # 99090467

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-10-06 Cont ID  
Sent By jleahy Date 1999-10-06 Time 15:50 Rev Time 1.00
Received By jleahy Date 1999-10-06 Time 15:49 Sent To  
Notes
2001-01-08 00:00:00EMERGENCY FEED FROM GENERATOR TO HAVE A
 DISCONNECT GROUPED WITH OTHER MAINS PER
 230-72B

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2000-01-19 Cont ID  
Sent By dlauderm Date 1999-10-12 Time 10:13 Rev Time 1.25
Received By dlauderm Date   Time   Sent To  
Notes
2001-01-08 00:00:00PASSED WITH PROVISOS:TS (659-8040)
 WATER AND SANITARY:ONCERNING STORMWATER
 1.DRAWINGS MUST BE THE ONES LAST REVISED
 AND APPROVED ON 11/19/99 STAMPED FORTA-
 HEALTH DEPARTMENT 11-23-99 WITH 2-2"ALED
 METERS AND A 4" PFL, AND A 6" LATERAL,
 ALL TO BE CONTRACTOR INSTALLED (ALL0);
 SHEETS, 6 OF 6).PPROVED THRU UTILITIES
 2.ADDITIONALLY IF THE 11-23-99 REVISIONS
 DO NOT SHOW IT A CLEAN-OUT MUST BE
 PLACED AT THE BACK OF SIDEWALK, SEE CITY
 DETAIL ON SHEET 5 OF 6.
 3.BACKFLOW PREVENTER LOCATION ON SHEETE-
 FS-1 IS WRONG.BACKFLOW PREVENTER BY
 (DCDA) WILL BE LOCATED AT BACK OF WALK.
 STORMWATER:
 PLAN SHEET 2 OF 6 AND CALCULATIONS
 SUBMITTED WITH 10-20-99 REVISED DATE OK.
 STREETS:
 1.STOP SIGN ON SOUTHWEST EXIT IS TO BE
 AT BACK OF SIDEWALK, NOT AT CURB (SEE
 SHEET 2 OF 6)
 2.STOP SIGN ON NORTHEAST EXIT IS TO BE
 AT BACK OF SIDEWALK, NOT IN DRIVEWAY
 RAMP (SEE SHEET 2 OF 6).THE PARKING
 LOT LIGHT ON SHEET SP-1 MAY INTERFERE
 WITH THIS STOP SIGN, PERHAPS THE STOP
 SIGN CAN BE MOUNTED TO THE LIGHT POLE,
 BUT THE LIGHT POLE SHOULD NOT BE THAT
 CLOSE TO THE DRIVEWAY.
 3.BOTH DRIVEWAY RAMPS ARE TO BE CONCRETE
 AND TO THE CITY DETAILS (SEE ATTACHED).
 4.I CAN NOT FIND ON THE DRAWINGS A
 STATEMENT THAT THE EXISTING DRIVEWAYS
 WILL BE REMOVED BY THE CONTRATOR, THEY
 WILL BE REMOVED BY THE CONTRACTOR AND
 REPLACED WITH CURBS THAT MATCH THE
 EXISTING.
 5.LANDSCAPING (PALM TREES) CAN NOT BE
 PLACED OVER THE WATER MAIN ON FLAGLER,
 REMOVE THEM (SEE SHEET 1/4 BY
 ENVIRONMENTAL DESIGN GROUP).
 6. IT IS MANDATORY THAT PLANTS BE PLACED
 AROUND THE BACKFLOW PREVENTERS SHOWN ON
 SHEET 2 OR 6 BY SIMMONS AND WHITE.
 7. SHEET E-1 DOES NOT SHOW THE TWO POLE
 MOUNTED PARKING LOT LIGHTS SHOWN ON
 SHEET SP-1 NEXT TO EACH DRIVEWAY.
 DUMPSTER ENCLOSURE:
 1.OK, EXCEPT, THE PLUMBING PLAN DOES NOT
 SHOW THE WATER LINE TO THE DUMPSTER AS
 SHOWN ON PAGE SP-2 AND REFERRING TO THE
 PLUMBING PLAN P-2, 3 OR 4.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-11-21 Cont ID  
Sent By mcarsill Date 2000-11-21 Time 13:23 Rev Time 0.00
Received By mcarsill Date 2000-11-21 Time 13:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-04-27 Cont ID  
Sent By hpiskura Date 2000-04-27 Time 10:47 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00APP'D ON PLAN 9/30/99 W/PROVISO

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-11-30 Cont ID  
Sent By ndenmark Date 2000-11-30 Time 14:07 Rev Time 0.33
Received By ndenmark Date 2000-11-30 Time 14:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-09-27 Cont ID  
Sent By ndenmark Date 1999-09-27 Time 11:07 Rev Time 1.00
Received By ndenmark Date 1999-09-27 Time 11:07 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 PROVIDE MINIMUM 18" CLEARANCE UNDER ROOF
 STANDS FOR MECHANICAL EQUIPMENT

Review Stop P PLUMBING
Rev No 5 Status P Date 2000-11-04 Cont ID  
Sent By tlarge Date 2000-11-04 Time 09:41 Rev Time 0.65
Received By tlarge Date 2000-11-04 Time 09:41 Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
 MANEUVERING CLEARANCES AT DOOR FOR
 TOILET ROOM #102 SHALL COMPLY W/FACBC
 SEC.4.13.6 AND FIG.25(B).
  
 CALL IF YOU HAVE QUESTIONS.
 561-659-8096,EXT.8377.

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-04-04 Cont ID  
Sent By tlarge Date 2000-04-04 Time 18:42 Rev Time 1.50
Received By tlarge Date 2000-04-04 Time 18:42 Sent To  
Notes
2001-01-08 00:00:00****************PROVISO*****************
 DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3.(10)(A).

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-01-20 Cont ID  
Sent By tlarge Date 2000-01-20 Time 08:14 Rev Time 0.75
Received By tlarge Date 2000-01-20 Time 08:14 Sent To  
Notes
2001-01-08 00:00:00THE REQD.NUMBER OF SANITARY FACILITIES
 FOR THE OCCUPANCY LOAD SHALL COMPLY W/
 TABLE 407 OF SPC.SEE SPC SEC.407.1.3.
  
 FLOOR DRAINS ARE REQD.INTHE TOILET ROOMS
 PER SPC SEC.409.4.1.1(SEE EXCEPTION).
  
 ALL COMMON AND PUBLIC AREA TOILET ROOMS
 SHALL BE FULLY ACCESSIBLE PER FACBC SEC.
 4.1.3(11).
  
 DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3.(10)(A).
  
 WATER PIPING TO HOSE BIBB AT DUMPSTER
 SHALL BE SHOWN ON THE PLBG.PLAN.

Review Stop P PLUMBING
Rev No 2 Status F Date 1999-11-18 Cont ID  
Sent By tlarge Date 1999-11-18 Time 17:15 Rev Time 1.50
Received By tlarge Date 1999-11-18 Time 17:15 Sent To  
Notes
2001-01-08 00:00:00SECONDARY DRAINAGE SHALL COMPLY W/TABLE
 A101.2(MIN.SIZE SCUPPER SHALL BE 6 X 12.
  
 THE REQD.NUMBER OF SANITARY FACILITIES
 FOR THE OCCUPANT LOAD SHALL COMPLY W/
 TABLE 407 OF SPC.

Review Stop P PLUMBING
Rev No 1 Status F Date 1999-10-07 Cont ID  
Sent By tlarge Date 1999-10-07 Time 12:00 Rev Time 1.50
Received By tlarge Date 1999-10-07 Time 12:00 Sent To  
Notes
2001-01-08 00:00:00WALLS IN TOILET ROOMS SHALL BE NON-
 ABSORBENT TO A HEIGHT OF 4'PER SBC SEC.
 1204.2.
  
 SUBMIT OCCUPANT LOAD PER TABLE 407 OF
 SPC.
  
 FLOOR DAINS ARE REQD.IN THE TOILET ROOMS
 PER SPC SEC.409.4.1.1.
  
 SINK IN LOUNGE SHALL COMPLY W/FACBC SEC.
 4.24.1-4.24.7.
  
 SECONDARY DRAINAGE FOR ROOF SHALL COMPLY
 W/SPC TABLE A101.2.
  
 SUBMIT STORM DRAINAGE RISER FOR REVIEW.
 SPC 104.2.1.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-01-07 Cont ID  
Sent By gjoyce Date 2000-01-07 Time 15:10 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***