Plan Review Details - Permit 99090280
Plan Review Stops For Permit 99090280
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 1999-11-24 Cont ID  
Sent By lmartine Date 1999-11-24 Time 13:25 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 1999-10-13 Cont ID  
Sent By lmartine Date 1999-10-13 Time 10:13 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-10-05 Cont ID  
Sent By jleahy Date 1999-10-05 Time 08:52 Rev Time 1.00
Received By jleahy Date 1999-10-05 Time 08:52 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 1999-12-17 Cont ID  
Sent By dlauderm Date 1999-12-17 Time 14:57 Rev Time 2.00
Received By dlauderm Date 1999-12-17 Time 14:57 Sent To  
Notes
2001-01-08 00:00:00PASSED WITH PREVISOS:
 THE DRIVEWAYS MUST CONCRETE PER CITY
 STANDARDS (IF REPLACED).
 THE FOLLOWING MUST BE SUBMITTED SIGNED
 AND SEALED BY A FLORIDA PROFESSIONAL
 ENGINEER (PE).
 3.HYDRAULIC COMPUTATIONS AND SUPPORTING
 DOCUMENTATION
 4.IMPERVIOUS AREA COMPUTATIONS
 A COPY OF THE POLLUTION PREVENTION
 PLAN SHALL BE KEPT ON SITE AT ALL
 TIMES DURING CONSTRUCTION. THE PLAN
 SHALL BE INSTALLED IN THE FIELD PRIOR TO
 ANY EARTHWORK. THE ENGINEER OF RECORD
 SHALL CERTIFY TO THE CITY, ON A MONTHLY
 BASIS, THAT THE PLAN IS WORKING PROPERLY
 AND AS DESIGNED. THE ENGINEER OF RECORD
 IS RESPONSIBLE TO CERTIFY IMPLEMENTATION
 OF THE PROVISIONS OF CITY ORDINANCE NO.
 3132-98 OF THE CITY CODE AT SUCH TIME
 THE PERMITTEE APPLIES FOR A CERTIFICATE
 OF OCCUPANCY FROM THE CITY BUILDING
 OFFICIAL.
 6.EVERY SIX MONTHS AFTER CONSTRUCTION A
 PE SHALL CERTIFY THAT THE PERMANENT
 POLLUTION PREVENTION STRUCTURES, DRY-WET
 WATER DETENTION FACILITIES, AND
 EXFILTRATION SYSTEMS ARE WORKING AS
 DESIGNED AND ARE IN GOOD OPERATING
 CONDITION. ALL CERTIFICATIONS MUST BE
 SUBMITTED TO:
 STORM WATER UTILITY ENGINEER
 CITY OF WEST PALM BEACH PUBLIC UTILITIES
 DEPARTMENT
 P.O. BOX 3366, WEST PALM BEACH, FL 33402
 THE CERTIFICATION MUST INCLUDE THE
 BUILDING PERMIT NUMBER, THE ADDRESS OF
 THE PROPERTY AND THE NAME OF THE
 ESTABLISHMENT/PROJECT CONSTRUCTED.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 1999-11-24 Cont ID  
Sent By lmartine Date 1999-09-28 Time 13:27 Rev Time 0.00
Received By lmartine Date 1999-09-20 Time 13:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-10-13 Cont ID  
Sent By lmartine Date 1999-10-13 Time 10:14 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-10-01 Cont ID  
Sent By ndenmark Date 1999-10-01 Time 11:38 Rev Time 0.33
Received By ndenmark Date 1999-10-01 Time 11:37 Sent To  
Notes
2001-01-08 00:00:00PROVISO;
 DUCT SMOKE DETECTOR TO BE TIED TO BLDG
 FIRE ALARM SYSTEM OR HORN AND STROBE FOR
 NOTIFICATION PER NFPA 90A 4-4.4.2 OR(.3)

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-12-22 Cont ID  
Sent By tlarge Date 1999-12-22 Time 15:09 Rev Time 1.00
Received By tlarge Date 1999-12-22 Time 15:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 1999-11-10 Cont ID  
Sent By tlarge Date 1999-11-10 Time 14:31 Rev Time 0.75
Received By tlarge Date 1999-11-10 Time 14:31 Sent To  
Notes
2001-01-08 00:00:00SIZE OF SHOWER SHALL COMPLY W/FACBC SEC.
 4.21.2.(EITHER 36"X 36",OR 30"X 60"MIN.)
  
 HANDICAP TOILET STALL SHALL COMPLY W/
 FACBC SEC.4.17.3 AND CONTAIN AN ACCESS-
 IBLE LAVATORY WITHIN THE STALL.(SEE
 EXCEPTION:NEW CONSTRUCTION)
  
 DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 4.1.3(10)(A) (PROVISIONS SHALL BE MADE
 FOR INDIVIDUALS IN WHEELCHAIRS AND THOSE
 WHO HAVE DIFFICULTY BENDING OR STOOPING)

Review Stop P PLUMBING
Rev No 1 Status F Date 1999-10-06 Cont ID  
Sent By tlarge Date 1999-10-06 Time 15:26 Rev Time 1.50
Received By tlarge Date 1999-10-06 Time 15:26 Sent To  
Notes
2001-01-08 00:00:00SHOWER SHALL COMPLY W/FACBC SEC.4.21.-
 4.21.8.DIMENSIONS SHALL COMPLY W/FACBC
 SEC.4.21 AND FIGURE 35.
  
 HANDICAP STALL SHALL COMPLY W/FACBC SEC.
 4.17.3.(SEE EXCEPTION:NEW CONSTRUCTION)
 CLEARLY SHOW ALL DIMENSIONS.
  
 DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3.(10)(A).
  
 SUBMIT ELEVATION DETAILS OF HANDICAP
 FIXTURES AND SHOW FIXTURE CLEARANCES PER
 FACBC.
  
 EACH WATER SUPPLY BRANCH LINE SHALL BE
 VALVED PER SPC SEC.610.4.2.

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***