Plan Review Details - Permit 99081302
Plan Review Stops For Permit 99081302
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-09-23 Cont ID  
Sent By hpiskura Date 1999-09-23 Time 14:18 Rev Time 0.00
Received By hpiskura Date   Time   Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-02-12 Cont ID  
Sent By dpalmer Date 2000-02-12 Time 08:00 Rev Time 0.00
Received By dpalmer Date 2000-02-12 Time 08:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-09-23 Cont ID  
Sent By dpalmer Date 1999-09-23 Time 07:59 Rev Time 0.00
Received By dpalmer Date 1999-09-23 Time 08:00 Sent To  
Notes
2001-01-08 00:00:00NOTES ORIG. ON PLANS BY JLEAHY. NOTES
 WERE ADDRESSED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-02-23 Cont ID  
Sent By rturnque Date 2000-02-23 Time 14:53 Rev Time 0.30
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-02-24 Cont ID  
Sent By ndenmark Date 2000-02-24 Time 15:43 Rev Time 0.33
Received By ndenmark Date 2000-02-24 Time 15:43 Sent To  
Notes
2001-01-08 00:00:00SEE LETTER ATTACHED TO PLAN FOR CALCULAT
 IONS AND DUCT SMOKE DETECTOR INFORMATION

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-02-24 Cont ID  
Sent By ndenmark Date 1999-09-08 Time 10:06 Rev Time 0.33
Received By ndenmark Date 1999-09-08 Time 10:06 Sent To  
Notes
2001-01-08 00:00:00CORRECTED BY SUBMITTED INFORMATION
 1) PROVIDE OUTSIDE AIR CALCULATIONS PER
 ASHRAE 62-89
 2) FAN SHUT DOWN BY DUCT SMOKE DETECTOR
 REQUIRED PER 1997 SMC 406.1 PROVIDE INFO
 ON DUCT SMOKE DETECTOR AND TIE IN TO BLD
 FIRE ALARM

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-02-11 Cont ID  
Sent By tlarge Date 2000-02-11 Time 16:20 Rev Time 0.50
Received By tlarge Date 2000-02-11 Time 16:20 Sent To  
Notes
2001-01-08 00:00:00****************PROVISO*****************
 HANDICAP DRINKING FOUNTAIN SHALL COMPLY
 W/FACBC SEC.4.1.3.(10)(A).

Review Stop P PLUMBING
Rev No 1 Status N Date 2000-02-11 Cont ID  
Sent By tlarge Date 1999-09-11 Time 08:36 Rev Time 0.75
Received By tlarge Date 1999-09-11 Time 08:36 Sent To  
Notes
2001-01-08 00:00:00SUBMIT WATER RISER FOR REVIEW THAT
 CLEARLY REFLECTS THE ENTIRE SCOPE OF
 WORK BEING PERFORMED.WATER SUPPLY
 CONTROL SHALL COMPLY W/SPC SEC.610.4.1,
 610.4.2.
  
 MIN.SIZE WASTE STACK FOR URINAL SHALL BE
 2"PER SPC SEC.1003.2.
  
 MIN. SIZE OF SANITARY LINE U/G SHALL BE
 2" PER SPC SEC.714.4.
  
 HANDICAP ACCESSIBLE WATER FOUNTAIN SHALL
 COMPLY W/FACBC SEC.4.1.3(10)(A).

Review Stop Z ZONING
Rev No 1 Status P Date 2000-02-29 Cont ID  
Sent By hpiskura Date 2000-02-25 Time 08:32 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***