Plan Review Details - Permit 99080943
| Plan Review Stops For Permit 99080943 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-09-29 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-09-29 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************PROVISO**************** | | | | | | 1)NOTE: NEED TO SUBMIT AIC RATING OF | | | EQUIPMENT AND BRKRS.AS PER ARTS;215-5/ | | | 110-9 | | | 2)NOTE:AS PER ART:210-8-A-6 ALL RECEPTS. | | | SERVING KITCHEN COUNTERSPACE ARE TO BE | | | GFI/GFI PROTECTED. | | | 3)NOTE:AS PER ART;250-81 GROUNDING | | | ELECTRODE CONDUCTOR TO GOT TO BLDG. | | | STEEL ALSO. | | | 4)NOTE:AS PER 1996-NFPA-72 SMOKE | | | DETECTORS ARE REQ`D INSIDE AND OUTSIDE | | | ALL SLEEPING ROOMS IN NEW CONSTRUCTION. | | | | | | NEED TO SUBMIT THE ABOVE INFORMATIONN | | | FOR APPROVAL BEFORE THE FIRST ROUGH | | | ELECTRICAL INSPECTION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-09-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
1999-09-29 |
Time |
15:00 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
1999-09-29 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
1999-11-18 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-11-18 |
Time |
20:36 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
1999-11-18 |
Time |
20:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
1999-10-29 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-10-29 |
Time |
09:16 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
1999-10-29 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT DETAIL OF REINFORCEMENT OF WALLS | | | FOR FUTURE INSTALLATION OF GRAB BARS AS | | | REQUIRED BY FEDERAL FAIR HOUSING ACT | | | 24 CFR 100.205 SEC.3 REQUIREMENT#6. | | | NOTE:ALL BATHROOMS WITHIN THE COVERED | | | DWELLING UNIT SHALL COMPLY. | | | | | | ALL BATHROMS IN THE DWELLING UNIT SHALL | | | COMPLY W/THE PROVISIONS OF FEDERAL FAIR | | | HOUSING ACT 24 CFR 100.205 (C)(3)(IV) | | | REQ.#7 (2) PARAGRAPH (A) OR (B).CLEAR | | | FLOOR SPACE SHALL BE PROVIDED AT | | | FIXTURES TO ALLOW A PERSON IN A WHEEL- | | | CHAIR OR OTHER MOBILITY AID USE OF THE | | | FIXTURES.CLEAR FLOOR SPACE SHALL BE | | | SHOWN ON THE PLANS AND DESIGNATE WHICH | | | OPTION OF REQUIREMENT #7 (A OR B) IS | | | BEING USED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
1999-10-29 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-10-27 |
Time |
15:13 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
1999-10-27 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
1999-08-28 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-08-28 |
Time |
06:42 |
Rev Time |
1.00 |
| Received By |
tlarge |
Date |
1999-08-28 |
Time |
06:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | LAYOUT OF W/M AND LAV.ON RISER DIAGRAM | | | DOESN'T MATCH FLOOR PLAN.A SEPARATE | | | STACK IS REQD.FOR THE LAV.SPC 104.2.1, | | | TABLE 908. | | | | | | UNITS SHALL COMPLY W/FEDERAL FAIR | | | HOUSING ACT/24 CFR 100.205,& FLA.STATUTE | | | 760. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
1999-12-06 |
|
|
Cont ID |
|
| Sent By |
jcaloger |
Date |
1999-10-06 |
Time |
11:42 |
Rev Time |
1.00 |
| Received By |
jcaloger |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-08-23 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-08-23 |
Time |
16:16 |
Rev Time |
0.50 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |