Plan Review Details - Permit 99080714
| Plan Review Stops For Permit 99080714 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
1999-11-19 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
1999-08-31 |
Time |
09:32 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. HEALTH DEPARTMENT TO APPROVE PLANS. | | | 2. ENGINEER TO PROVIDE INFORMATION ON | | | GLAZING SYSTEM. AS PER NOTE ON PLAN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-10-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-10-28 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-10-28 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************PROVISO**************** | | | | | | 1)NOTE:EXISTING RISER DIAGRAM SHOWS | | | 3 PHASE EQUIPMENT AND ONLY SINGLE PHASE | | | WIRING.???? FROM MAIN TO PANEL. | | | 2)NOTE:IF PVC CONDUIT IS USED IN FEEDING | | | FROM PANEL "A" TO PANEL "B" THEN SIZE | | | EQUIPMENT GROUND SHALL BE SIZED FROM | | | TABLE:250-95 | | | 3)NOTE:RISER DIAGRAM SHOWS PANEL"B" AS | | | BEING INSTALLED AS NEW ? BUT PANEL | | | SCHEDULE SHOWS AS BEING EXISTING?? | | | IF PANEL "B" IS NEW THEN PROVIDE AIC | | | RATING OF BRANCH BREAKERS.AS PER ARTS: | | | 215-5/110-9 | | | | | | ALL THE ABOVE INFORMATION NEEDS TO BE | | | SUBMITTED FOR REVIEW AND APPROVAL BEFORE | | | FIRST ROUGH ELECTRICAL INSPECTION IS | | | CALLED IN. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
1999-08-31 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
1999-08-31 |
Time |
09:33 |
Rev Time |
0.50 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-11-17 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-11-17 |
Time |
07:11 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
1999-11-17 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | ALL PRIOR MECH WORK TO BE INSPECTED | | | UNDER REISSUED MECH PERMITS | | | SEPARATE MECHANICAL PERMITS REQUIRED FOR | | | WALK IN COOLER AND HOOD AND SUPPRESSION | | | SYSTEM, SUBMIT PLANS WITH MECH PERMIT | | | APPLICATION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
1999-11-06 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-11-06 |
Time |
08:52 |
Rev Time |
0.65 |
| Received By |
tlarge |
Date |
1999-11-06 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
1999-08-30 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-08-30 |
Time |
09:15 |
Rev Time |
1.25 |
| Received By |
pschmitz |
Date |
1999-08-30 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLANS SHALL BE REVIEWED BY DEPT.OF | | | BUSINESS REG.PRIOR TO REVIEW BY THIS | | | DEPT.SPC SEC.101.4.7. | | | | | | SUBMIT MANUF.SHEETS FOR ALL GAS EQUIP. | | | STD.GAS CODE SEC.402.1. | | | | | | SIZE ALL SECTIONS OF THE GAS RISER AND | | | SHOW ALL CUT LENGTHS OF PIPE.STD.GAS | | | CODE SEC.302,305.4 | | | | | | INDICATE GAS SUPPLY PRESSURE ON PLANS | | | PER STD.GAS CODE SEC.305.2. | | | | | | SUPPLY COMBUSTION AIR CALCULATIONS FOR | | | ALL GAS EQUIPMENT.STD.GAS CODE SEC.402.4 | | | | | | SIZE ALL INDIRECT WASTE LINES ON THE | | | RISER.COMPLY W/SPC SEC.713.3,TABLE 713.2 | | | | | | SHT.A-3.NOTE #11-"M" COPPER IS NOT | | | PERMITTED FOR U/G USE PER COUNTYWIDE | | | AMENDMENTS TO STD.PLBG.CODE SEC.611.3. | | | | | | PLANS SHALL BE SIGNED AND SEALED PER | | | SPC SEC.104.2.3. | | | | | | SUBMIT SANITARY RISER FOR ANY PLBG. | | | CHANGES TO THE RESTROOM.SPC 104.2.1. | | | | | | RESUBMIT 10-13-99 DENIED SEPERATE PREMIT | | | FOR PLUMBING SEE NOTES ON SHT A-3 | | | END OF COMMENTS PES |
|
|
|