Plan Review Details - Permit 99071771
| Plan Review Stops For Permit 99071771 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-09-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-09-03 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-09-03 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************PROVISO******************** | | | | | | 1)NOTE:AS PER 1996 NFPA-72 2-2.1.1.1 | | | REQ.SMOKE DETECTORS INSIDE AND OUTSIDE | | | ALL BEDROOMS IN NEW CONSTRUCTION HOMES. | | | 2)NOTE:AS PER ART 210--8-A-6 REQ. ALL | | | RECEPTS. SERVING KITCHEN COUNTER SPACE | | | TO BE GFI. | | | 3)NOTE AS PER ART:250-81 GROUNDING | | | ELECTRODE CONDUCTOR REQ. TO BLDG.STEEL. | | | 4)NOTE:AS PER ART,210-52 LIVING ROOM | | | REAR WALLS REQ.OUTLETS 2`,6`,12` RULE, | | | PLEASE CORRECT. | | | 5) NOTE:AS PER ART 210-52E REQ`S OUTLETS | | | AT THE FRONT AND REAR OF NEW HOUSES | | | 6)NOTE:AHU#1 IS SHOWN AT MASTER BEDROOM | | | SIDE OF HOUSE,,NO COND.UNIT SHOWN,, | | | PLEASE DRAW IN WITH DISC,AS REQ`D PER | | | 440-11 AND SHOW WP GFI AS PER 210-63 | | | 7)NOTE:ELECTRICAL FOR SPA/WHIRLPOOL TUB | | | IS TO BE GFI/GFI PROTECTED. | | | 8)NOTE:NEED TO SUBMIT AIC RATING OF ALL | | | EQUIPMENT!!PANELS,DISC`S AND BREAKERS. | | | AS PER ARTS;110-9 AND 215-5 | | | 9)NOTE:AS PER ART;210-52G GARAGE GFI. | | | REQ`D. | | | | | | ALL THE ABOVE NEEDS TO BE SUBMITTED | | | AND APPROVED BEFORE FIRST ELECTRICAL | | | ROUGH INSPECTION!! |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-08-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
1999-08-07 |
Time |
14:08 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
1999-08-07 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-08-09 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-08-09 |
Time |
11:40 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
1999-08-09 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
1999-09-22 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-09-22 |
Time |
10:10 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | | | | 1)PROVIDE 2 COPIES OF CURRENT PRODUCT | | | APPROVAL FOR ARCH TRANSOMS. | | | | | | 2)PROVIDE 2 COPIES OF CURRENT PRODUCT | | | APPROVAL FOR BUTT GLASS. | | | | | | 3)PROVIDE 2 COPIES OF CURRENT PRODUCT | | | APPROVAL FOR GARAGE DOORS TO SATISFY | | | DESIGN PRESSURES ON PLANS. | | | | | | 4)PROVIDE STORM PANEL INSTALLATION | | | SCHEDULE AND KEY PLAN WITH SPECIFIC | | | MOUNTING AND ANCHORS TO BE USED. | | | | | | PLEASE SUBMIT PRIOR TO FIRST INSPECTION |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
1999-09-22 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-09-21 |
Time |
09:14 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
1999-09-13 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED SEE CHECKLIST |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-08-02 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-08-02 |
Time |
18:10 |
Rev Time |
0.50 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |