Plan Review Details - Permit 99071295
| Plan Review Stops For Permit 99071295 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
1999-09-23 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-09-23 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
1999-09-24 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-08-30 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
tlarge |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-08-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-08-18 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-08-18 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************PROVISO***************** | | | | | | 1)NOTE:SHEET E-3 OUTLET SPACING TO MEET | | | LOCAL PALM BEACH COUNTY AMENDMENTS ART: | | | 210-50D 12`OF UNENCUMBERED WALL SPACE | | | IN OFFICE AND EVERY 20` FOR STORAGE | | | AREAS . | | | 2) NOTE:SHEET E-2 RISER DIAGRAM SHOWS | | | PANEL NSCA FEEDING NSCB WITH 50 AMP | | | OVERCURRENT PROTECTION, BUT SHEET E-7 | | | NSCA PANEL SCEDULE SHOWS 125A FEED. | | | PLEASE CORRECT. | | | 3)NOTE:SHEET E-2 ALSO SHOWS NSCA FEEDING | | | NSCC WITH 70AMP OVERCURRENT PROTECTION | | | YET SHEET E-7 SHOWS 125A BRK. | | | | | | PLEASE HAVE CORRECTIONS MADE AND | | | SUBMITTED FOR APPROVAL BEFORE ROUGH | | | INSPECTION. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
1999-08-30 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-08-30 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-08-16 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-08-16 |
Time |
13:41 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
1999-08-16 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
1999-09-23 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-09-23 |
Time |
17:04 |
Rev Time |
2.00 |
| Received By |
tlarge |
Date |
1999-09-23 |
Time |
17:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
1999-09-24 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-09-21 |
Time |
15:52 |
Rev Time |
2.25 |
| Received By |
tlarge |
Date |
1999-09-21 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | WALLS IN RESTROOMS AND STAFF TOILET | | | SHALL BE NON-ABSORBENT MATERIAL TO 4' | | | PER SBC SEC.1204.2. | | | | | | SUBMIT ELEVATION DETAILS FOR HANDICAP | | | DRINKING FOUNTAIN AND CLEARLY SHOW | | | DIMENSIONS FOR MOUNTING HEIGHTS OF ALL | | | HANDICAP FIXTURES .(SHOW CLEAR FLOOR | | | SPACE UNDER FIXTURES.COMPLY W/FACBC.) | | | | | | SUBMIT STORM DRAINAGE RISER FOR REVIEW. | | | SPC SEC.104.2.1. | | | | | | ROOF SYSTEM SHALL BE SUPPLIED W/ | | | PROVISIONS FOR SECONDARY DRAINAGE PER | | | SPC SEC.1109. | | | | | | CIRCUIT AND LOOP VENTING SYSTEM SHALL | | | COMPLY W/SPC SEC.914.1,TABLE 920.3. | | | | | | WET VENTS SHALL RECEIVE THE DISCHARGE | | | FROM FIXTURE DRAINS ONLY PER COUNTYWIDE | | | AMENDMENTS SEC.911.1.1 | | | | | | INDICATE SLOPE OF PIPE ON PLANS.COMPLY | | | W/SPC 714.1,714.2. | | | | | | ISLAND VENT FOR MORGUE SINK SHALL | | | CONNECT TO HORIZONTAL BRANCH AND SHALL | | | BE 3" PER SPC 103.7. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-09-24 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-08-04 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
tlarge |
Date |
|
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BREAKROOM SINKS SHALL COMPLY W/F.A.C.B.C | | | SEC.4.24.1 - 4.24.7. | | | | | | ROOMS #106 & 107-THE ACESSIBLE WATER | | | CLOSET SHALL BE DIAGONAL TO THE DOOR PER | | | F.A.C.B.C.SEC 4.17.3(2). | | | | | | ACCESIBLE D.F.SHALL COMPLY W/F.A.C.B.C. | | | SEC.4.1.3.(10)(A). | | | | | | STAFF TOILETS SHALL BE HANDICAP ACCESS- | | | IBLE PER F.A.C.B.C.SEC.4.1.2(6). | | | | | | FLOOR DRAIN IS REQ'D.IN THE STAFF TOILET | | | ROOM PER SPC SEC.409.4.1.1 | | | | | | WALLS IN RESTROOMS AND STAFF TOILET | | | SHALL BE NON-ABSORBENT MATERIAL PER SBC | | | SEC.1204.2. | | | | | | SHT.A-6-SHOW MOUNTING HEIGHTS OF | | | ALL HANDICAP FIXTURES AND ACCESSORIES. | | | COMPLY W/F.A.C.B.C. | | | | | | SHOWER IN STAFF BATHROOM SHALL COMPLY W/ | | | F.AC.B.C. SEC.4.21.1. | | | | | | SUBMIT STORM DRAINAGE RISER FOR REVIEW. | | | COMPLY W/SPC SEC.1108. | | | | | | ROOF SYSTEM SHALL BE SUPPLIED W/ | | | PROVISIONS FOR SECONDARY DRAINAGE PER | | | SPC SEC.1109. | | | | | | CIRCUIT AND LOOP VENTING SYSTEM SHALL | | | COMPLY W/SPC SEC.914.1. | | | | | | INDICATE SLOPE OF SANITARY PIPING ON | | | PLAN.COMPLY W/SPC 714.1,714.2. |
|
|
|