Plan Review Details - Permit 99071111
Plan Review Stops For Permit 99071111
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-07-28 Cont ID  
Sent By dpalmer Date 1999-07-28 Time 16:10 Rev Time 0.00
Received By dpalmer Date 1999-07-28 Time 16:10 Sent To P
Notes
2001-01-08 00:00:00**************PROVISO******************
  
 NEED TO SUBMIT AIC RATING OF EQUIPMENT
 ARTS:215-5 110-9
 BEFORE ROUGH INSPECTION

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-07-31 Cont ID  
Sent By jleech Date 1999-07-31 Time 09:14 Rev Time 0.50
Received By jleech Date 1999-07-31 Time 09:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-02-09 Cont ID  
Sent By tlarge Date 2000-02-09 Time 06:04 Rev Time 0.33
Received By tlarge Date 2000-02-09 Time 06:04 Sent To  
Notes
2001-01-08 00:00:00REVISED GAS RISER.

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-09-10 Cont ID  
Sent By tlarge Date 1999-09-10 Time 09:20 Rev Time 0.50
Received By tlarge Date   Time 09:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-09-10 Cont ID  
Sent By dpalmer Date 1999-07-28 Time 16:12 Rev Time 0.65
Received By tlarge Date 1999-07-29 Time 07:39 Sent To  
Notes
2001-01-08 00:00:00MAX.OF 2 WATER CLOSETS PERMITTED ON 3"
 BUILDING DRAIN PER STD.PLBG.CODE TABLE
 714.1 FOOTNOTE #3.
  
 MIN.SIZE OF DRAINAGE PIPING UNDERGROUND
 SHALL BE 2" PER SPC SEC.714.4.
  
 FIXTURES DOWNSTREAM OF WATER CLOSETS
 SHALL BE VENTED PER SPC SEC.913.2
  
 KIT.SINK AND LAV.ARE NOT VENTED.COMPLY
 W/SPC SEC.901.2.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 1999-09-10 Cont ID  
Sent By jgomez Date 1999-09-10 Time 10:48 Rev Time 1.00
Received By jgomez Date   Time   Sent To O
Notes
2001-01-08 00:00:00PROVISO:
 1-PROVIDE COMPLETE FRAMING DETAILS FOR
 BAY WINDOWS. SPECIFY ALL CONNECTORS.
 SEC. 104.2.2 CITY AMENDMENTS.
 2-PROVIDE PRODUCT APPROVALS FOR: ROOF
 TILE, OVAL WINDOWS, ENTRY DOORS, FIXED
 WINDOW ABOVE ENTRY DOORS.
 3-PROVIDE CEILING FANS AS REQUIRED FOR
 CREDIT TAKEN IN ENERGY CALCULATIONS.
 4-SPECIFY FOOTING FOR BEARING WALL
 BETWEEN GARAGE AND LAUNDRY AREA.
 SEC. 104.2.2 CITY AMENDMENTS.
 *WHAT IS THE WIDTH OF FOOTING A?
 *SPECIFY SIZE AND REINFORCEMENT OF
 CONCRETE EDGE AT REAR PORCH SLAB.
 5-PROVIDE DRAFSTOPPING AT SECOND FLOOR.
 SEC. 2305.2.2 SBC 1997.
 6-PROVIDE COMPLETE DETAILS/SECTIONS
 THRU STAIRS. SPECIFY ALL FRAMING
 MEMBERS. SEC. 104.2.2 CITY AMENDMENTS.
 *SPECIFY THE RISER/TREAD RATIO. SEC.
 1007.3 SBC 1997.
 *PROVIDE FIREBLOCKING. SEC. 2304.1 SBC
 7-COMPLETELY SPECIFY THE CEILING
 CONSTRUCTION AT FRONT AND REAR PORCHES
 AS PER SEC. 2504.2 SBC 1997 AND ASTM
 C926 AND ASTM C1063.
 8-SEE PLANS FOR ADDITIONAL COMMENTS.
 9-PROVIDE COMPLETE SPECIFICATIONS AND
 MOUNTING DETAILS FOR AHU'S SPECIFY
 ALL FASTENERS. SEC. 104.2.2 CITY
 AMENDMENTS.
 10-PROVIDE COMPLETE SPECIFICATIONS AND
 SECTIONS/DETAILS FOR BUTT GLAZING AS
 PER SECTIONS 2405.3 AND 2406 SBC 1997.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-09-10 Cont ID  
Sent By jgomez Date 1999-09-07 Time 18:11 Rev Time 3.50
Received By jgomez Date   Time   Sent To O
Notes
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO THE COUNTY.
 2-ARCHITECT OF RECORD TO SIGN AND SEAL
 ALL DRAWINGS.SEC.104.2.3 OF CITY
 AMENDMENTS TO SBC 1997.
 3-PROVIDE COMPLETE FRAMING DETAILS FOR
 BAY WINDOWS. SPECIFY ALL CONNECTORS.
  
 4-PROVIDE PRODUCT APPROVALS FOR: ROOF
 TILE, OVAL WINDOWS,ENTRY DOORS, FIXED
 WINDOW ABOVE ENTRY DOORS.
 5-PROVIDE CEILING FANS AS REQUIRED BY
 CREDIT TAKEN IN ENERGY CALCULATIONS.
 6-*PROVIDE FOOTING FOR BEARING WALL
 BETWEEN GARAGE AND LAUNDRY AREA.
 SEC. 104.2.2 CITY AMENDMENTS.
 *WHAT IS THE WIDTH OF FOOTING A?
 *SPECIFY SIZE AND REINFORCEMENT OF
 CONCRETE EDGE AT REAR PORCH SLAB.
 7-PROVIDE DRAFSTOPPING AT SECOND FLOOR.
 SEC. 2305.2.2 SBC 1997.
 8-*PROVIDE COMPLETE DETAILS/SECTIONS
 THRU STAIRS. SPECIFY ALL FRAMING
 MEMBERS.SEC 104.2.2 CITY AMENDMENTS.
 *SPECIFY THE RISER/TREAD RATIO.
 SEC. 1007.3 SBC 1997.
 *PROVIDE FIREBLOCKING. SEC.2305.1.
 9-SPECIFY THE CEILING CONSTRUCTION AT
 FRONT AND REAR PORCHES. SEC 2504.2
 SBC 1997. (ASTM C926 AND ASTM C1063).
 10-REVISE ENERGY CALCULATIONS. OWNER AND
 CONTRACTOR IS RJS BUILDER NOT PAPARONE
 HOMES.
 THE CLIMATE ZONE IS #8, NOT SOUTH.
 SOUTH IS REFERING TO THE REGION.
 11-SEE PLANS FOR ADDITIONAL COMMENTS.
 12-PROVIDE COMPLETE SPECIFICATIONS AND
 MOUNTING CONDITIONS FOR AHU.
 13-PROVIDE COMPLETE SPECIFICATIONS AND
 SECTIONS/DETAILS FOR BUTT GLAZING AS
 PER SECTIONS 2405.3 AND 2406 SBC 1997.

Review Stop Z ZONING
Rev No 1 Status P Date 1999-07-19 Cont ID  
Sent By gjoyce Date 1999-07-19 Time 08:18 Rev Time 0.50
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***