Plan Review Details - Permit 99070917
Plan Review Stops For Permit 99070917
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 1999-11-03 Cont ID  
Sent By hpiskura Date 1999-10-25 Time 10:28 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 1999-11-03 Cont ID  
Sent By hpiskura Date 1999-09-27 Time 15:36 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-11-03 Cont ID  
Sent By hpiskura Date 1999-08-27 Time 16:06 Rev Time 7.00
Received By sgraham Date   Time   Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-08-12 Cont ID  
Sent By hpiskura Date 1999-08-27 Time 16:07 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 1999-11-03 Cont ID  
Sent By lmartine Date 1999-11-03 Time 14:58 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00ENG FAX DELRIO CRAP HHP

Review Stop ENG ENGINEERING CSD
Rev No 1 Status   Date   Cont ID  
Sent By dlauderm Date 1999-10-14 Time 09:43 Rev Time 0.00
Received By dlauderm Date   Time   Sent To  
Notes
2001-01-08 00:00:00SOLID WASTE: APPROVED
  
 ENGINEERING SERVICES: APPROVED
  
 STORMWATER DISAPPROVED:
 STORM WATER UTILITY REQUIREMENTS PER
 CITY ORDINANCE NO. 3132-98 (REGULATION
 OF STORM WATER DISCHARGE PURSUANT TO
 FEDERAL LAW)
 THE FOLLOWING
 ARE THE STORM WATER UTILITY DIVISION
 REQUIREMENTS TO OBTAIN A STORM WATER
 CONSTRUCTION PERMIT:
 1.CONSTRUCTION PLANS, DETAILS AND
 SPECIFICATIONS, SIGNED AND SEALED BY
 A PROFESSIONAL ENGINEER, MUST BE
 SUBMITTED.
 2.HYDRAULIC COMPUTATIONS AND
 SUPPORTING DOCUMENTATION, SIGNED AND
 SEALED BY A PROFESSIONAL ENGINEER,
 MUST BE SUBMITTED.
 3.IMPERVIOUS AREA COMPUTATIONS,PER
 SIGNED AND SEALED BY A PROFESSIONALION
 ENGINEER, MUST BE SUBMITTED.SUANT TO
 4.SUBMIT A POLLUTION PREVENTION PLAN
 SIGNED AND SEALED BY A PROFESSIONALG
 ENGINEER:TORM WATER UTILITY DIVISION
 A.THE PLAN SHALL BE KEPT ON SITE AT
 ALL TIMES DURING CONSTRUCTION.
 B.THE PLAN SHALL BE INSTALLED IN THE
 FIELD PRIOR TO ANY EARTHWORK.ALED BY
 C.THE ENGINEER OF RECORD SHALL
 CERTIFY TO THE CITY, ON A MONTHLY
 BASIS, THAT THE PLAN IS WORKING
 PROPERLY AND AS DESIGNED. SIGNED AND
 D. THE ENGINEER OF RECORD ISINEER,
 RESPONSIBLE TO CERTIFY IMPLEMENTATION
 OF THE PROVISIONS OF CITY ORDINANCE
 NO. 3132-98 OF THE CITY CODE AT SUCH
 TIME THE PERMITTEE APPLIES FOR A
 CERTIFICATE OF OCCUPANCY FROM THE CITY
 BUILDING OFFICIAL.BY A PROFESSIONAL
 E.EVERY SIX MONTHS AFTER CONSTRUCTION
 A PROFESSIONAL ENGINEER SHALL CERTIFY
 THAT THE PERMANENT POLLUTION PREVENTION
 STRUCTURES, DRY-WET WATER DETENTIONTHE
 FACILITIES, AND EXFILTRATION SYSTEMS
 ARE WORKING AS DESIGNED AND ARE IN GOOD
 OPERATING CONDITION. ON A MONTHLY
 F.ALL CERTIFICATIONS MUST BEG
 SUBMITTED TO: STORM WATER UTILITY
 ENGINEER, CITY OF WEST PALM BEACH,
 PUBLIC UTILITIES DEPARTMENT, 1000 45TH
 STREET, SUITE 15, P.O. BOX 3366, WEST
 PALM BEACH, FLORIDA 33402. THET SUCH
 CERTIFICATION MUST INCLUDE THE PERMIT
 NUMBER, THE ADDRESS OF THE PROPERTYITY
 AND THE NAME OF THE ESTABLISHMENT
 AND PROJECT CONSTRUCTED.ER CONSTRUCTION
 A PROFESSIONAL ENGINEER SHALL CERTIFY
 THAT THE PERMANENT POLLUTION PREVENTION
 STRUCTURES, DRY-WET WATER DETENTION
 FACILITIES, AND EXFILTRATION SYSTEMS
 ARE WORKING AS DESIGNED AND ARE IN GOOD
 OPERATING CONDITION.
 F.ALL CERTIFICATIONS MUST BE
 SUBMITTED TO: STORM WATER UTILITY
 ENGINEER, CITY OF WEST PALM BEACH,
 PUBLIC UTILITIES DEPARTMENT, 1000 45TH
 STREET, SUITE 15, P.O. BOX 3366, WEST
 PALM BEACH, FLORIDA 33402. THE
 CERTIFICATION MUST INCLUDE THE PERMIT
 NUMBER, THE ADDRESS OF THE PROPERTY
 AND THE NAME OF THE ESTABLISHMENT AND
 OR PROJECT CONSTRUCTED.
  
 WATER AND SANITARY: APPROVED W/PREVISO
 BACKFLOW PREVENTERS MUST BE OUTSIDE
 EASEMENTS AND METERS MUST BE AT WEST
 SIDE AND IN EASEMENT.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-08-19 Cont ID  
Sent By hpiskura Date 1999-08-27 Time 16:08 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 1999-09-03 Cont ID  
Sent By ndenmark Date 1999-09-03 Time 10:54 Rev Time 0.25
Received By ndenmark Date 1999-09-03 Time 10:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-09-03 Cont ID  
Sent By ndenmark Date 1999-08-16 Time 12:13 Rev Time 0.50
Received By ndenmark Date 1999-08-16 Time 12:13 Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1) ALL DUCTWORK IN UNCONDITIONED SPACES
 TO BE MIN. 1 1/2INCH(R-6) SUPPLY AND
 RETURN
 2) PROVIDE REFRIGERANT QUANTITY CALCULA-
 TIONS TO SHOW COMPLIANCE W/ 1997 SMC
 CHAPTER 11

Review Stop P PLUMBING
Rev No 4 Status N Date 1999-10-18 Cont ID  
Sent By tlarge Date 1999-10-18 Time 11:21 Rev Time 0.75
Received By tlarge Date 1999-10-18 Time 11:21 Sent To  
Notes
2001-01-08 00:00:00NO CHANGES TO PLBG.

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-09-23 Cont ID  
Sent By tlarge Date 1999-09-23 Time 18:01 Rev Time 0.75
Received By tlarge Date 1999-09-23 Time 18:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 1999-09-04 Cont ID  
Sent By tlarge Date 1999-09-04 Time 09:14 Rev Time 0.75
Received By lsmith Date 1999-09-04 Time 09:14 Sent To  
Notes
2001-01-08 00:00:00MIN.FIXTURE REQS.FOR 38 PERSONS SHALL
 COMPLY W/TABLE 407 OF SPC.(2 W.C.'S EACH
 FOR MALES AND FEMALES,AND 2 LAVS.EACH.)
  
 DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3(10)(A).
  
 CLEANOUTS IN BLDG.SEWER SHALL COMPLY
 W/SPC SEC.710.2.4(2)(NOT MORE THAN 80'
 INTERVALS.)

Review Stop P PLUMBING
Rev No 1 Status F Date 1999-08-07 Cont ID  
Sent By tlarge Date 1999-08-07 Time 10:49 Rev Time 1.00
Received By tlarge Date 1999-08-07 Time 10:49 Sent To  
Notes
2001-01-08 00:00:00SHT.C-2-SHOW HORIZONTAL DISTANCE BETWEEN
 WATER SERVICE AND SANITARY SEWER .COMPLY
 W/SPC SEC.608.3.
  
 CLEANOUTS IN BUILDING SEWER SHALL BE ED
 SPACED PER SPC SEC.710.2.4(2).
  
 SHT.A2.1-SINKIN LOUNGE SHALL COMPLY W/
 F.A.C.B.C. SECS.4.24.1- 4.24.7.
  
 DRINKING FOUNTAIN SHALL COMPLY W/
 F.A.C.B.C. SEC.4.1.3.(10)(A).
  
 SHOW OCCUPANT LOAD TO ENSURE COMPLIANCE
 W/TABLE 407 OF SPC.
  
 MAIN VENT REQ'D.FORSANITARY SYSTEM.
 SIZE SHALL COMPLY W/SPC SEC.904.3.1 AND
 RUN UNDIMINISHED IN SIZE THRU ROOF.
  
 WATER SUPPLY CONTROL SHALL COMPLY W/SPC
 SEC.610.4.2.

Review Stop Z ZONING
Rev No 1 Status P Date 1999-08-24 Cont ID  
Sent By sgraham Date 1999-11-03 Time 15:17 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00NEED TRIP ALLOCATION CHART PRIOR TO THE
 ISSUANCE OF THE CERTIFICATE OF OCCUPANCY