Plan Review Details - Permit 99070088
| Plan Review Stops For Permit 99070088 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
1999-07-23 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-07-23 |
Time |
14:45 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
1999-07-22 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | 1) PROVIDE PRODUCT APPROVAL AND TESTING | | | FOR NEW EXTERIOR WINDOWS AND DOORS. | | | CITY ADMENDMENTS 1O4.2.2 AND 1606.1 | | | | | | SUBMIT PRIOR TO FIRST INSPECTION. | | | | | | 2) PROVIDE MISSLE IMPACT RESISTANCE | | | INFORMATION.CITY ADMENDMENTS 1606.4 | | | AND 1707.4. UNDER SEPERATE PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-07-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-07-21 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-07-21 |
Time |
12:26 |
Sent To |
P |
|
| Notes |
| 2001-01-08 00:00:00 | ***************PROVISO****************** | | | | | | NOTE: 210-70 SWITCH AND LIGHT REQ`D AT | | | MEANS OF EGRESS. | | | NOTE:210-52C REQ`D RECEPTS. SERVING | | | KITCHEN COUNTER SPACE. | | | NOTE:210-8-A-6 ALL RECEPTS. SERVING KIT- | | | -CHEN COUNTER SPACE ARE TO BE GFI/GFI | | | PROTECTED. | | | NOTE:210-63 WP GFI RECEPT. REQ`D FOR A/C | | | EQUIP. | | | NOTE:210-52A MISSING RECEPTS.AS PER | | | 2`6`12`RULE. | | | NOTE:NFPA-72 SMOKE DETECTORS REQ`D | | | INSIDE AND OUTSIDE BEDROOMS. | | | NOTE:SHOW COMPLETE RISER DIAGRAM TO | | | INCLUDE METER,PANEL,DISC, WIRE SIZE, | | | CONDUIT SIZES.GRPOUNDING ELECTRODE | | | SYSTEM.GRND.ROD,CWP,ETC. | | | NOTE:440-11 A/C DISC. REQ`D | | | | | | NEED THE ABOVE INFORMATION RESUBMITTED | | | AND APPROVED BEFORE ROUGH INSPECTION. | | | | | | NOTE:410-8 LIGHTING CLEARANCES REQ`D | | | FOR CLOSETS AND THE TYPE OF FIXTURES | | | PERMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-07-21 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-07-21 |
Time |
13:03 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
1999-07-21 |
Time |
13:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
1999-07-23 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-07-23 |
Time |
14:18 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
1999-07-23 |
Time |
14:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-07-21 |
Time |
12:26 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CLEARLY DETAIL ON THE PLANS WHAT PLBG. | | | IS NEW AND WHAT IS EXISTING.SPC 104.2.1. | | | | | | SUBMITA SANITARY RISER DIAGRAM FOR | | | CHANGES TO THE DRAINAGE SYSTEM.SPC | | | 104.2.1. |
|
|
|