Plan Review Details - Permit 99070071
| Plan Review Stops For Permit 99070071 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-07-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-07-21 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
1999-12-06 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************PROVISO******************** | | | | | | NOTE: NEED AIC RATING OF EQUIPMENT. | | | NOTE: GROUNDING CONDUCTOR REQ`D FROM | | | DISC. TO PANEL | | | NOTE: SMOKE DETECTORS REQ`D BEDROOMS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-07-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
1999-07-17 |
Time |
12:22 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
1999-07-17 |
Time |
12:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-07-24 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-07-24 |
Time |
09:46 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
1999-07-24 |
Time |
09:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
1999-08-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
1999-08-10 |
Time |
17:57 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
|
Time |
|
Sent To |
O |
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-PROVIDE TRUSS DWGS SIGNED AND SEALED, | | | INCLUDING THE TRUSS LAYOUT.SEC 104.2.2 | | | CITY AMENDMENTS. | | | DESIGNER OF RECOR TO REVIEW ALL TRUSS | | | DWGS PRIOR TO SUBMITTAL TO THIS OFFICE | | | 2-ENTRY DOOR TO HAVE 32"MIN.CLEAR OPEN'G | | | TABLE 1004 SBC 1997. | | | 3-PROVIDE SAFETY GLASS AT GUEST BATH. | | | SEC 2405.2 SBC 1997. | | | 4-GAS APPLIANCES IN GARAGE.SPECIFY HOW | | | TO COMPLY WITH SEC. 402.7 SGC 1997. | | | 5-FOOTING F2 TO BE 16"MIN. DEEP AS PER | | | 1804.1.3SBC/97 & 1804.1.9 CITY AMENDME | | | 6-PROVIDE THE DESIGN PRESSURES AT ALL | | | EXTERIOR OPENINGS.SEC. 1606 SBC 1997. | | | 7-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOORS, HORIZONTAL WINDOWS,MULLIONS FOR | | | TRANSOMS ABOVE SLIDING GLASS DOORS, | | | ROUND WINDOWS. | | | 8-SEE PLANS FOR ADDITIONAL COMMENTS. | | | | | | NOTE: | | | REVISE ORIGINAL DRAWINGS AS REQUIRED. | | | ALSO, ALL NOTES AND SPECIFICATIONS NEED | | | TO BE UPDATED TO 1997 SBC. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-07-08 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-07-08 |
Time |
09:07 |
Rev Time |
0.50 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|