| Plan Review Stops For Permit 99061417 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
1999-07-31 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-07-31 |
Time |
08:55 |
Rev Time |
2.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
Z |
|
| Notes |
| 2001-01-08 00:00:00 | OWES IMPACT FEES & RADON |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-01-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2000-01-27 |
Time |
08:02 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2000-01-27 |
Time |
08:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-07-31 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-07-31 |
Time |
08:57 |
Rev Time |
99.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
1999-07-31 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-07-31 |
Time |
08:56 |
Rev Time |
99.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2000-03-27 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-03-27 |
Time |
07:31 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-03-27 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ***********NOTES NOTES NOTES************ | | | RELOCATION OF OUTSIDE AIR | | | | | | EXTENSION OF COND. STAND LEGS ON ROOF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2000-03-16 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-03-16 |
Time |
08:25 |
Rev Time |
0.50 |
| Received By |
cthirben |
Date |
2000-03-16 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-01-26 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-01-26 |
Time |
08:17 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-01-26 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
1999-09-07 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-09-07 |
Time |
12:31 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
1999-09-07 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-09-07 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-07-10 |
Time |
12:40 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
1999-07-10 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************DENIED****************** | | | 1) FIRE DAMPERS REQUIRED WHERE DUCT PEN- | | | ETRATES RATED WALL CORRIDOR [124] | | | 2) CONDENSING UNITS TO BE MOUNTED ON | | | STANDS PROVIDING MIN. 18" CLEARANCE BE- | | | TWEEN FINISHED ROOF SURFACE AND BOTTOM | | | OF STAND | | | 3) HORN AND STROBE REQUIRED FOR NOTIFI- | | | CATION OF FAN SHUT DOWN BY DUCT SMOKE | | | DETECTOR IF NOT TIED TO BLDG FIRE ALARM | | | SYSTEM 1996 NFPA 90A 4-4.4.3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
1999-09-23 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-09-23 |
Time |
17:39 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
1999-09-23 |
Time |
17:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
1999-09-24 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-09-04 |
Time |
07:22 |
Rev Time |
1.50 |
| Received By |
tlarge |
Date |
1999-09-04 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CURBS IN HANDICAP SHOWERS SHALL BE MAX. | | | 1/2" PER FACBC SEC.4.21.7. | | | | | | SHT.8.3-CLEAR FLOOR SPACE UNDER HANDICAP | | | LAV.SHALL BE MIN.29" PER FACBC SEC. | | | 4.19.2. | | | | | | CIRCUIT AND LOOP VENTING SYSTEM FOR THE | | | SANITARY SYSTEM SHALL COMPLY W/SPC SEC. | | | 914.1.(A RELIEF VENT,STACK VENT OR VENT | | | STACK IS REQD.DOWNSTREAM OF FIRST HORIZ. | | | FIXTURE CONNECTION.SPC SEC.914.1. | | | | | | A DRINKING FOUNTAIN IS REQD.ON THE 2ND | | | FLOOR PER SPC TABLE 407 AND MUST COMPLY | | | W/FACBC SEC.4.1.3.(10)(A),4.15. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-09-24 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-07-11 |
Time |
09:32 |
Rev Time |
1.25 |
| Received By |
tlarge |
Date |
1999-07-11 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | WOMEN'S RESTROOM-THE ACCESIBLE WATER | | | CLOSET SHALL BE LOCATED IN THE CORNER, | | | DIAGONAL TO DOOR.F.A.C.B.C.SEC.4.17.3. | | | | | | SINKS IN LOUNGE/BREAKROOM SHALL COMPLY | | | W/F.A.C.B.C.SEC.4.1.1(A),4.24.1-4.24.7. | | | (THESE AREAS ARE NOT CLASSED AS WORK | | | AREAS.) | | | | | | SHT.8.3-CLEAR FLOOR SPACE UNDER H.C.LAV. | | | SHALL COMPLY W/F.A.C.B.C.SEC.4.19.2. | | | | | | SIZE OF SHOWER STALLS SHALL COMPLY W/ | | | F.A.C.B.C. SEC.4.21.2-4.21.8 & FIGURES | | | 35(A)(B). | | | | | | H.C.DRINKING FOUNTAIN SHALL COMPLY W/ | | | F.A.C.B.C.SEC.4.1.3(10)(A). | | | | | | SUBMIT OCCUPANT LOAD FOR MINIMUM FIXTURE | | | REQ'S.PER STD.PLBG.CODE TABLE 407. | | | | | | INDICATE SLOPE OF SANITARY SYSTEM ON | | | PLAN PER STD.PLBG.CODE SEC.705.2,705.3. | | | | | | CIRCUIT AND LOOP SYSTEM SHALL COMPY | | | W/STD.PLBG.CODE SEC.914.1-914.3.4. | | | | | | WATER TO APPLIANCES SHALL BE PROTECTED | | | AGAINST BACKFLOW PER STD.PLBG.CODE SEC. | | | 606. | | | | | | WATER SUPPLY CONTROL SHALL COMPLY W/ | | | STD.PLBG.CODE SEC.610.4.1,610.4.2. | | | | | | WATER PURIFICATION SYSTEM SHALL BE NSF | | | APPROVED PER STD.PLBG.CODE SEC.615.1. | | | | | | MAX.OF 2 FIXTURES SHALL BE SUPPLIED BY | | | 1/2" C.W.& 4 FIXTURES BY 1/2"H.W.PER | | | COUNTYWIDE AMENDMENTS TO STD.PLBG.CODE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-09-24 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-07-31 |
Time |
08:57 |
Rev Time |
0.75 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEED LEVEL 1 SITE PLAN REVIEW |
|
|