| Plan Review Stops For Permit 99060989 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-03-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-03-14 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
1999-11-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
1999-09-24 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-09-20 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-09-20 |
Time |
07:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
1999-11-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
1999-09-24 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
1999-09-24 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
1999-09-24 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
1999-11-17 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-11-17 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
ndenmark |
Date |
1999-11-17 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-11-17 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-09-20 |
Time |
11:24 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
1999-09-20 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CORRECTED BY REVISION 11/17/99 | | | PROVIDE PLANS SHOWING DUCT LAYOUT AND | | | CFM DISTRIBUTION | | | PROVIDE EXHAUST FAN DUCT TERMINATION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
1999-11-22 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-11-22 |
Time |
06:39 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
1999-11-22 |
Time |
06:38 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************PROVISO***************** | | | DRINKING FOUNTAINS ARE REQD.IN EACH BAY | | | AND SHALL COMPLY W/FACBC SECS.4.1.3(10) | | | (A) & 4.15. | | | | | | ALL TOILET ROOMS SHALL COMPLY W/FACBC. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
1999-11-17 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-11-17 |
Time |
06:52 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
1999-11-17 |
Time |
06:51 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DRINKLING FOUNTAINS ARE REQD.IN EACH BAY | | | PER TABLE407 OF SPC AND SHALL COMPLY W/ | | | FACBC SEC.4.15. | | | | | | DRINKING FOUNTAINS SHALL BE SHOWN ON | | | FLOOR PLAN,SANITARY AND WATER RISERS. | | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
1999-10-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-10-23 |
Time |
11:39 |
Rev Time |
1.50 |
| Received By |
tlarge |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 10-23-99 SEE ADDENDUM UNSAT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
1999-09-18 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-09-18 |
Time |
09:03 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
1999-09-18 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | COVER SHEET-HANDICAP BATHROOM REQS.SHALL | | | COMPLY W/FACBC.(SEE FIGURES 29 (A)(B). | | | | | | SUBMIT OCCUPANT LOAD OF BUILDING. | | | VERIFICATION BY OWNER REQD.PER TABLE 407 | | | 0F SPC. | | | | | | DRINKING FOUNTAINS ARE REQD.IN THE BAYS | | | PER SPC TABLE 407 AND SHALL COMPLY W/ | | | FACBC SEC.4.1.3.(10)(A). | | | | | | FLOOR DRAINS ARE REQD.IN THE TOILET | | | ROOMS PER SPC 409.4.1.1. | | | | | | SUBMIT A WATER ISOMETRIC FOR REVIEW PER | | | SPC 104.2.1. | | | | | | BREAKROOM SINK SHALL BE SHOWN ON THE | | | SANITARY ISOMETRIC.SPC 104.2.1. | | | | | | ALL TOILET ROOMS SHALL BE HANDICAP | | | ACCESSIBLE PER FACBC | | | SEC.4.1.3(11),FIGS.29 (A)(B). | | | | | | BREAKROOM SINK SHALL BE HANDICAP ACCESS- | | | IBLE PER FACBC PER FACBC SEC.4.24.1- | | | 4.24.7. | | | | | | WATER CLOSETS NOT PERMITTED ON WET VENTS | | | PER SEC 911.1.1,911.1.2. | | | ADDENDUM 10-23-99 PES | | | ADDRESS ALL COMMENTS ON PLAN REVIEW | | | DELETE OR VOID OLD REVISIONS SEC 104.2.1 | | | SUBMIT ELEVATIONS OF ALL H/C FIXTURES. | | | FIXTURE CLERANCE TO COMPLY WITH FACBC. | | | NO FACILITIES SHOWN FOR UNIT #2. | | | END OF COMMENTS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2000-03-13 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-03-13 |
Time |
09:14 |
Rev Time |
0.15 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-08-23 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-06-14 |
Time |
13:41 |
Rev Time |
0.50 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEEDS A LEVEL 1 SITE PLAN REVIEW PPRC |
|
|