Plan Review Details - Permit 99060898
Plan Review Stops For Permit 99060898
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-23 Cont ID  
Sent By dpalmer Date 1999-06-23 Time 16:33 Rev Time 0.00
Received By dpalmer Date 1999-06-23 Time 16:33 Sent To  
Notes
2001-01-08 00:00:00************PROVISO****************
  
 NEED TO SUBMIT AIC RATING FROM FAULT
 CURRENT CACULATIONS. 215-5
 EQUIP.GRND. COND.
 BLDG.STEEL GRND.ALSO.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-07-10 Cont ID  
Sent By jleech Date 1999-07-10 Time 12:51 Rev Time 0.50
Received By jleech Date 1999-07-10 Time 12:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-07-10 Cont ID  
Sent By pschmitz Date 1999-07-10 Time 09:00 Rev Time 0.50
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 1999-09-16 Cont ID  
Sent By jgomez Date 1999-09-16 Time 18:42 Rev Time 2.00
Received By jgomez Date 1999-09-16 Time 18:41 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-ENTRY DOORS CAN'T HAVE STORM PANELS
 BECAUSE THE MAIN EGRESS OF THE HOUSE
 WILL BE BLOCKED. REVISE INSTALLATION
 SCHEDULE AS REQUIRED.
 2-ARCHITECT SPECIFIED GIRDER TRUSS AT
 FRONT PORCH. NEED TO SPECIFY UPLIFT
 CONNECTORS.
 *PROVIDE COMPLETE SPECIFICATIONS FOR
 DETAIL B-A6. SEE COMMENTS ON PLANS.
 *REVISE CONNECTOR C-A6 AS REQUIRED IN
 ORDER TO RESIST THE UPLIFT LOADS
 SPECIFIED IN ENGINEERED DRAWINGS.
 3-ENGINEERED TRUSS LAYOUT DOES NOT SHOW
 GIRDER TRUSS AT FRONT PORCH SPECIFIED
 BY ARCHITECT. REVISE AS REQUIRED.
 *TRUSS DRAWINGS NEED TO BE UPDATED TO
 ASCE 7-95.
 CUT AND PASTED ENGINEERED TRUSS COPIES
 WILL NOT BE RECEIVED. ONLY ORIGINAL
 COPIES WITH ORIGINAL CALCULATIONS WILL
 BE ACCEPTED.
 4-REVISE ORIGINAL DRAWINGS AS REQUIRED
 SHOWING THE CORRECTIONS/CLARIFICATIONS.
 5-SLIDING GLASS DOORS:
 *USE ONLY THE REINFORCED DOORS IN ORDER
 TO MEET THE DESIGN PRESSURES SPECIFIED
 BY THE ARCHITECT.
 PROVIDE PRODUCT APPROVAL FOR SLIDING
 GLASS DOORS ASSEMBLY WITH TRANSOM ABOVE
 6-MINIMUM CLEAR OPENING AT BEDROOM
 WINDOWS TO BE 5.0 S.F. AS PER SECTION
 1005.4.4 SBC 1994. PROVIDE THE EXACT
 DIMENSIONS FOR WINDOWS AT BEDROOM #2 TO
 VERIFY CLEAR OPENING PRIOR TO
 INSTALLATION.
 7-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOORS PRIOR TO INSTALLATION.
 8-GARAGE DOOR PRODUCT PRODUCT DOESN'T
 MEET THE DESIGN PRESSURES CALCULATED BY
 ARCHITECT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-09-16 Cont ID  
Sent By jgomez Date 1999-07-20 Time 17:13 Rev Time 1.00
Received By jgomez Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-06-15 Cont ID  
Sent By gjoyce Date 1999-06-15 Time 09:08 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***