Plan Review Details - Permit 99060896
Plan Review Stops For Permit 99060896
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-23 Cont ID  
Sent By dpalmer Date 1999-06-23 Time 16:21 Rev Time 0.00
Received By dpalmer Date 1999-06-23 Time 16:21 Sent To  
Notes
2001-01-08 00:00:00*************PROVISO*******************
  
 NEED TO SUBMIT AIC RATING FROM FAULT
 CURRENT CALCS.
 GRND, AND GRND.OF EQUIP.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-07-10 Cont ID  
Sent By jleech Date 1999-07-10 Time 12:53 Rev Time 0.50
Received By jleech Date 1999-07-10 Time 12:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-07-10 Cont ID  
Sent By pschmitz Date 1999-07-10 Time 09:18 Rev Time 0.50
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 1999-09-28 Cont ID  
Sent By jgomez Date 1999-09-28 Time 13:39 Rev Time 2.00
Received By jgomez Date 1999-09-28 Time 13:39 Sent To O
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1*ARCHITECT SPECIFIED GIRDER TRUSS AT
 FRONT PORCH. PROVIDE COMPLETE DETAIL
 AND SPECIFY ALL CONNECTORS.
 *PROVIDE COMPLETE SPECIFICATIONS AND
 SIZES FOR FOR DETAIL B-6.
 *REVISE CONNECTOR C-A6 AS REQUIRED TO
 RESIST THE UPLIFT LOADS CALCULATED ON
 ENGINEERED TRUSSES.
 2-ENGINEERED TRUSS LAYOUT DOESN'T SHOW
 GIRDER TRUSS AT FRONT PORCH. REVISE AND
 PROVIDE ENGINEERING AS REQUIRED.
 -TRUSS DRAWINGS NEED TO BE UPDATED TO
 ASCE 7-95.
 CUTTING, PASTING AND COPYING OF ALL
 ENGINEERED TRUSSES WILL NOT BE ACCEPTED
 3-REVISE ALL ORIGINAL DRAWINGS SHOWING
 ALL CORRECTIONS/CLARIFICATIONS.
 4-PROVIDE PRODUCT APPROVAL FOR SLIDING
 GLASS DOORS WITH TRANSOM ABOVE ASSEMBLY
 5-MINIMUM CLEAR OPENING AT BEDROOM #2 TO
 BE 5 S.F. SEC. 1005.4.4 SBC 1997.
 PROVIDE THE EXACT DIMENSIONS FOR SUCH
 WINDOWS PRIOR TO INSTALLATION.
 6-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOORS PRIOR TO INSTALLATION.
 7-GARAGE DOOR PRODUCT APPROVAL DOESN'T
 MEET THE DESIGN PRESSURES CALCULATED BY
 THE ARCHITECT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 1999-07-20 Cont ID  
Sent By jgomez Date 1999-07-20 Time 17:12 Rev Time 1.00
Received By jgomez Date   Time   Sent To D
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-06-15 Cont ID  
Sent By gjoyce Date 1999-06-15 Time 09:12 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***