Plan Review Details - Permit 99060289
Plan Review Stops For Permit 99060289
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-16 Cont ID  
Sent By dpalmer Date 1999-06-16 Time 18:04 Rev Time 0.00
Received By dpalmer Date 1999-06-16 Time 18:04 Sent To  
Notes
2001-01-08 00:00:00*************PROVISO*******************
  
 NEED TO SUBMIT FAULT CURRENT CACULATIONS
 AND HAVE AIC RATING DRAWN ON PANEL SCHD.
 ART.215-5
 NOTE:SMOKE DETECTORS REQ`D INSIDE AND
 OUTSIDE BEDROOMS.
 NOTE:ALL RECEPTS.SERVING KITCHEN
 COUNTER ARE TO BE GFI/GFI PROTECTED.
 ART.210-8-A-6
 NOTE:GROUNDIG ELECTRODE CONDUCTOR
 TO GRND. ROD,BLDG.STEEL.
  
 NEED TO HAVE ABOVE INFORMATION BEFORE
 ROUGH INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-07-10 Cont ID  
Sent By jleech Date 1999-07-10 Time 07:41 Rev Time 0.50
Received By jleech Date 1999-07-10 Time 07:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-07-11 Cont ID  
Sent By tlarge Date 1999-07-11 Time 10:28 Rev Time 0.30
Received By tlarge Date 1999-07-11 Time 10:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-07-11 Cont ID  
Sent By tlarge Date 1999-07-02 Time 15:06 Rev Time 0.50
Received By tlarge Date 1999-07-02 Time 15:06 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SANITARY RISER THAT COMPLIES W/
 STANDARD PLBG.CODE. SPC 104.2.1,104.3.1.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-08-04 Cont ID  
Sent By jcaloger Date 1999-08-03 Time 17:06 Rev Time 1.50
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-06-07 Cont ID  
Sent By gjoyce Date 1999-06-07 Time 17:00 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***