Plan Review Details - Permit 99060262
Plan Review Stops For Permit 99060262
Review Stop E ELECTRICAL
Rev No 3 Status P Date 1999-10-04 Cont ID  
Sent By dpalmer Date 1999-10-04 Time 10:47 Rev Time 0.00
Received By dpalmer Date 1999-10-04 Time 10:47 Sent To  
Notes
2001-01-08 00:00:00**************PROVISO**************
  
 NOTE:STILL REQ. AIC RATING OF EQUIPMENT
 FIG.FROM FAULTCURRENT CALCS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 1999-08-20 Cont ID  
Sent By dpalmer Date 1999-08-20 Time 10:03 Rev Time 0.00
Received By dpalmer Date 1999-08-20 Time 10:03 Sent To  
Notes
2001-01-08 00:00:00************PROVISO******************
  
 ATTACHED SAME NOTES FROM FIRST PROVISO
 NEED AIC RATING.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-08-06 Cont ID  
Sent By dpalmer Date 1999-08-06 Time 07:17 Rev Time 0.00
Received By dpalmer Date 1999-08-06 Time 07:17 Sent To P
Notes
2001-01-08 00:00:00***************PROVISO******************
  
 1)NOTE:NEED TO SUBMIT AIC RATING FROM
 FAULT CURRENTCALCULATIONS.110-9/215-5
 2)NOTE:SMOKE DETECTORS REQ`D INSIDE
 AND OUTSIDE BEDROOMS NFPA-72
 3)NOTE:KITCHEN RECEPT.210-52C
 4)NOTE:GFI RECEPT.REQ`D AT C/UNIT
 ART,210-63
 5)NOTE:RECEPT.FOR JACUZZI TO BE GFI AND
 ACCESSIBLE.
 6)NOTE:OTHER MISSING OUTLETS AS PER
 ART;210-52
 7)NOTE:GROUNDING ELECTRODE CONDUCTOR
 TO GO TO BLDG.STEEL ALSO.
 8)NOTE:PLANS SHOW MAIN DISC.WITH METER
 AT SIDE OF HOUSE BUT NOT ON RISER
 DIAGRAM???
  
 NEED ALL THE ABOVE SUBMITTED AND
 APPROVED BEFORE ROUGH ELECTRICAL
 INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-08-07 Cont ID  
Sent By tlarge Date 1999-08-19 Time 13:24 Rev Time 0.50
Received By jleech Date 1999-08-07 Time 08:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-03-16 Cont ID  
Sent By tlarge Date 2000-03-16 Time 18:03 Rev Time 0.30
Received By tlarge Date 2000-03-16 Time 18:02 Sent To  
Notes
2001-01-08 00:00:00REVISSED GAS RISER.

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-09-30 Cont ID  
Sent By tlarge Date 1999-09-30 Time 11:12 Rev Time 0.50
Received By tlarge Date 1999-09-30 Time 11:05 Sent To  
Notes
2001-01-08 00:00:00PROVISO
  
 REVISED SANITARY RISER REQD.

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-08-19 Cont ID  
Sent By tlarge Date 1999-08-19 Time 13:24 Rev Time 0.30
Received By tlarge Date 1999-08-19 Time 13:24 Sent To  
Notes
2001-01-08 00:00:00NEW PLANS APPROVED.

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-08-07 Cont ID  
Sent By dpalmer Date 1999-08-07 Time 08:10 Rev Time 0.33
Received By tlarge Date 1999-08-07 Time 07:23 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-08-18 Cont ID  
Sent By jcaloger Date 1999-08-05 Time 08:49 Rev Time 3.00
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-07-12 Cont ID  
Sent By gjoyce Date 1999-06-07 Time 16:53 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00NO SURVEY, NO LOT SIZE