Plan Review Details - Permit 99051186
Plan Review Stops For Permit 99051186
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 1999-09-03 Cont ID  
Sent By hpiskura Date 1999-09-03 Time 08:18 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 1999-08-23 Cont ID  
Sent By hpiskura Date 1999-08-23 Time 10:29 Rev Time 3.50
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 1999-07-31 Cont ID  
Sent By hpiskura Date 1999-07-31 Time 13:07 Rev Time 3.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 1999-07-09 Cont ID  
Sent By hpiskura Date 1999-07-09 Time 10:03 Rev Time 0.00
Received By hpiskura Date 1999-06-29 Time 10:02 Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 14 Status F Date 2000-10-24 Cont ID  
Sent By dpalmer Date 2000-10-24 Time 21:53 Rev Time 0.00
Received By dpalmer Date 2000-10-24 Time 21:53 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: PLEASE SEE LOAD CALCULATIONS FOR
 PANEL "B" LOAD SHOWN FOR PANEL"G" DOES
 NOT CORRELATE WITH WHAT IS SHOWN ON "B"
 SCHEDULE. PLEASE NOTE THAT THE LOADS
 TOTALLED FROM ALL PANELS EXCEED RATING
 OF 3000 AMP MAIN. THIS WAS A CONCERN
 WHEN DOING PLAN REVIEWS IN THE BEGINING
 AND THOSE LOADS WERE TAKEN OFF. NOW
 LOAD EXCEEDS MAIN SERVICE SIZE.
  
 PLEASE NOTE THAT ALL LOAD CALCULATIONS
 WILL NEED TO BE SUBMITTEDAND SHOWN.
 ALL LOAD CALCULATIONS ARE TO BE DONE
 ACCORDING NEC AND IF SERVICE IS NOT OF
 SUFF. SIZE THEN SERVICE WILL NEED TO BE
 INCREASED. ALSO PLEASE NOTE THAT A MEET-
 -ING IS GOING TO BE REQUESTED FOR ANY
 INCREASE IN SERVICE AND FOR ANY QUESTION
 -S AND/OR VERIFICATION OF LOAD CALCS.
  
  
 PLEASE SUBMIT ALL THE ABOVE INFORMAITON
 SIGNED AND SEALED BY ENGINEER OF RECORD
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 JAKE LEAHY
 CHEIF ELECTRICAL INSPECTOR
  
 CITY OF WEST PALM BEACH
 561-659-8096 EXT 8372 FOR DV PALMER AND
 8451 FOR J LEAHY.

Review Stop E ELECTRICAL
Rev No 13 Status P Date 2000-10-16 Cont ID  
Sent By dpalmer Date 2000-10-16 Time 18:21 Rev Time 0.00
Received By dpalmer Date 2000-10-16 Time 18:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 12 Status P Date 2000-10-10 Cont ID  
Sent By dpalmer Date 2000-10-10 Time 09:26 Rev Time 0.00
Received By dpalmer Date 2000-10-10 Time 09:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 11 Status P Date 2000-10-10 Cont ID  
Sent By dpalmer Date 2000-10-10 Time 09:02 Rev Time 0.00
Received By dpalmer Date 2000-10-10 Time 09:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 10 Status P Date 2000-09-26 Cont ID  
Sent By dpalmer Date 2000-09-26 Time 18:08 Rev Time 0.00
Received By dpalmer Date 2000-09-26 Time 18:08 Sent To  
Notes
2001-01-08 00:00:00SHEET E-2 ONLY

Review Stop E ELECTRICAL
Rev No 9 Status P Date 2000-09-13 Cont ID  
Sent By jleahy Date 2000-09-13 Time 13:30 Rev Time 3.00
Received By jleahy Date 2000-09-13 Time 13:29 Sent To  
Notes
2001-01-08 00:00:00REV. #8

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2000-09-13 Cont ID  
Sent By jleahy Date 2000-09-13 Time 13:29 Rev Time 2.00
Received By jleahy Date 2000-09-13 Time 13:28 Sent To  
Notes
2001-01-08 00:00:00REV. #6

Review Stop E ELECTRICAL
Rev No 7 Status F Date 2000-08-01 Cont ID  
Sent By jleahy Date 2000-08-01 Time 09:30 Rev Time 2.45
Received By jleahy Date 2000-09-13 Time 13:28 Sent To  
Notes
2001-01-08 00:00:00THERE ARE SEVERAL SETS OF PLANS AND NONE
 OF THEM HAVE THE SAME AMOUNT OF PAGES
 PLEASE FIX AND RESUBMIT!!!!!!!!!!!!!!!!

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2000-07-26 Cont ID  
Sent By dpalmer Date 2000-07-26 Time 20:28 Rev Time 0.00
Received By dpalmer Date 2000-07-26 Time 20:28 Sent To  
Notes
2001-01-08 00:00:00************* NOTE********************
  
  
 PLAN REVISIONS WERE ONLY SUBMITTED FOR
 SHEET E-2 . OUTSTANDING ISSUES PER
 JAKE LEAHY.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2000-06-20 Cont ID  
Sent By jleahy Date 2000-06-20 Time 09:06 Rev Time 0.00
Received By jleahy Date 2000-09-11 Time 13:56 Sent To  
Notes
2001-01-08 00:00:001- AIC RATING STILL 200K ON CERTAIN
 PANELS.....

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2000-06-06 Cont ID  
Sent By jleahy Date 2000-06-06 Time 10:31 Rev Time 0.00
Received By rcordove Date 2000-06-19 Time 09:07 Sent To  
Notes
2001-01-08 00:00:001- ALL PANELS ARE SHOWN WITH 200K RATED
 BUSS
  
 2- OUTLET SPACING IS NOT TO CODE!!!!!!!

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2000-04-21 Cont ID  
Sent By jleahy Date 2000-04-21 Time 10:34 Rev Time 4.00
Received By jleahy Date 2000-04-20 Time 08:27 Sent To  
Notes
2001-01-08 00:00:00PG.E-4 100 AMP DISC IN CORNER MUST MEE
 110-26.
  
 PG.E-9 LOADS ON PANEL "ACB" SHOWS NO
 MOTOR CONTIBUTION PER 430-24,25,26
  
 PG.E-13 "K" PANEL SHOWS THE OUTLETS AN
 VENTILATING EQUIPMENT INCLUDED IN THE
 DEMAND FOR THE THE KITCHEN EQUIP.SEE
 220-22 FOR REQUIREMENTS!!!!!!!!!!!!!!
  
 PG.E-13 THE LOAD CALCULATION FOR "MDP"
 SHOWS LOADS THAT DO NOT MATCH WHAT IS
 SHOWN ON THE INDIVIDUAL PANELS LOAD CALC
 "ACB","A","B" SHOW LARGER THAN WHAT IS
 SHOWN ON THE CALC FOR "MDP"!!!!!!!!!!!!
  
 PG.E-13PANELS "A,B" SHOW A 200A DISC
 WITH A LOAD OF 25,000VA HOW WAS THIS
 FIGURED?200AMPS AT 208 = 72,000 VA
  
 PG.E-13 ALL PANELS AND DISC. ON LOAD
 SIDE OF THE MDP SHOW NO AIC RATING!!!!
  
 PLEASE CHECK ALL LOAD CALCULATIONS FOR
 COMPLIANCE WITH THE CODE!!!!!BASED ON
 WHAT IS SHOWN THE 3000 AMP MAIN IS TOO
 SMALL!!!

Review Stop E ELECTRICAL
Rev No 2 Status P Date 1999-09-27 Cont ID  
Sent By dpalmer Date 1999-09-27 Time 12:27 Rev Time 0.00
Received By dpalmer Date 1999-09-27 Time 12:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-07-01 Cont ID  
Sent By dpalmer Date 1999-07-01 Time 15:29 Rev Time 0.00
Received By jleahy Date 2000-06-06 Time 10:31 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2000-10-05 Cont ID  
Sent By mgonzale Date 2000-10-05 Time 16:28 Rev Time 1.00
Received By mgonzale Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED REVISIONS.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 1999-07-09 Cont ID  
Sent By hpiskura Date 1999-07-09 Time 11:25 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED ON PERMIT 9902122

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2000-09-27 Cont ID  
Sent By mcarsill Date 2000-09-27 Time 12:48 Rev Time 0.00
Received By mcarsill Date 2000-09-27 Time 11:43 Sent To  
Notes
2001-01-08 00:00:00PLAN REVIEW FOR FIRST FLOOR LIFE SAFETY
 DRAWING.
 1) IF ALL OF THE EXIT DOORS IN THE
 HORIZONTAL PLANE ARE AT LEAST 36" WIDE,
 THEY PROVIDE 1 1/2 UNITS OF EXIT WIDTH
 AND CAN PROVIDE EXITING FOR 150 PERSONS.
 2) PLAN DOES NOT INDICATE WHAT PURPOSE
 THE PRE-FUNCTION LOBBY SERVES AND WHAT
 IF ANY OCCUPANT LOADS ARE EXPECTED FROM
 THIS AREA.
 3) PLAN DOES NOT INDICATE RATED FIRE
 WALL LOCATIONS FOR CORRIDORS PRE-
 FUNCTION 106 AND 111. SINCE THESE
 THESE PROVIDE EXITING FOR 30 OR MORE
 PERSONS ONE HOUR FIRE SEPARATION IS
 REQUIRED. OPENINGS ARE TO BE PROTECTED
 WITH RATED FIRE DOORS.
 4) EXIT SIGNS SHOULD BE INCLUDED WITH
 PLANS SO EXITING LOCATIONS ARE CLEARLY
 IDENTIFIED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-09-21 Cont ID  
Sent By mcarsill Date 2000-09-21 Time 14:12 Rev Time 0.00
Received By mcarsill Date 2000-09-21 Time 14:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-07-09 Cont ID  
Sent By hpiskura Date 1999-07-09 Time 10:04 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVISO ON PLAN 6/1/99

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2000-10-06 Cont ID  
Sent By ndenmark Date 2000-10-06 Time 06:47 Rev Time 0.25
Received By ndenmark Date 2000-10-06 Time 06:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2000-10-02 Cont ID  
Sent By ndenmark Date 2000-10-02 Time 16:25 Rev Time 0.50
Received By ndenmark Date 2000-10-02 Time 16:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2000-08-16 Cont ID  
Sent By cthirben Date 2000-08-16 Time 07:08 Rev Time 1.00
Received By cthirben Date 2000-08-16 Time 07:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2000-07-26 Cont ID  
Sent By cthirben Date 2000-07-26 Time 14:00 Rev Time 0.00
Received By cthirben Date 2000-07-26 Time 14:01 Sent To  
Notes
2001-01-08 00:00:00NOTE:
 OKED WITH NCD......

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-07-18 Cont ID  
Sent By cthirben Date 2000-07-18 Time 15:56 Rev Time 1.00
Received By cthirben Date 2000-07-18 Time 15:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 1999-11-15 Cont ID  
Sent By ndenmark Date 1999-11-15 Time 15:08 Rev Time 0.25
Received By ndenmark Date 1999-11-15 Time 15:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-06-02 Cont ID  
Sent By ndenmark Date 1999-06-02 Time 12:47 Rev Time 2.00
Received By ndenmark Date 1999-06-02 Time 12:47 Sent To  
Notes
2001-01-08 00:00:00*************PROVISO********************
 1) STORAGE CLOSETS WITH JANITOR SINKS TO
 HAVE EXHAUST FROM SPACE SEE AC-1 STORAGE
 ROOM 103 PER 1994 SMC 501.4
 2) DUCTS PENETRATING RATED WALLS TO HAVE
 FIRE DAMPERS AT PENETRATION PER 1994 SMC
 610.1 SEE ELEC ROOM ON AC-2

Review Stop P PLUMBING
Rev No 9 Status P Date 2000-09-10 Cont ID  
Sent By pschmitz Date 2000-09-10 Time 12:46 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 8 Status F Date 2000-08-27 Cont ID  
Sent By tlarge Date 2000-08-27 Time 06:58 Rev Time 3.50
Received By tlarge Date 2000-08-27 Time 05:15 Sent To  
Notes
2001-01-08 00:00:001)3"STACK TO 2ND FLOOR CANNOT CONNECT TO
 THE CIRCUIT AND LOOP SYSTEM FOR THE 2ND.
 FLOOR PER SPC SEC.914.1.
  
 2)SHT.P-7-THE GREASY WASTE SYSTEM SHALL
 BE DESIGNED TO COMPLY W/SPC SEC.921.(A
 VENT IS ALSO REQD.DOWNSTREAM OF THE
 FIRST FIXTURE DRAIN ON THE SYSTEM.)
  
 3)A MANUAL SHUT-OFF VALVE IS REQD.AT THE
 SOLENOID VALVE W/A UNION DOWNSTREAM OF
 SOLENOID VALVE PER NFPA SEC.5.5.4.
  
 4)SHOW REQD.VALVE UPSTREAM OF MP REG.FOR
 WATER HEATERS PER NFPA SEC.3.10.1.
  
 5)INDICATE TABLE UTILIZED TO SIZE 2 PSI
 SYSTEM TO WATER HEATERS.
  
 6)REGULATORS SHALL BE VENTED TO ATMOS-
 PHERE PER NFPA 54 SEC.2.8.4.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 7 Status F Date 2000-08-04 Cont ID  
Sent By tlarge Date 2000-08-04 Time 18:47 Rev Time 1.50
Received By tlarge Date 2000-08-04 Time 17:57 Sent To  
Notes
2001-01-08 00:00:001)THERE IS CONFLICTING INFORMATION ON
 SHT.P-8 REGARDING THE GAS.COMPLY W/
 ATTACHED GAS REQS.AND CLEAN-UPTHE PLANS.
 DELETE INFORMATION THAT IS OLD OR NOT
 DIRECTLY RELATED TO THIS INSTALLATION.
  
 IF YOU HAVE ANY QUESTIONS CALL
 561-659-8096,EXT.8377.
  
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 6 Status F Date 2000-04-20 Cont ID  
Sent By tlarge Date 2000-04-20 Time 18:54 Rev Time 2.50
Received By tlarge Date 2000-04-20 Time 18:54 Sent To  
Notes
2001-01-08 00:00:00WATER HEATERS LOCATED ABOVE THE FIRST
 FLOOR CEILING SHALL BE EQUIPPED W/PANS
 AND DRAINS PER COUNTYWIDE AMENDMENTS TO
 SPC SEC.507.8.1.
  
 SHUT OFF VALVES ARE REQD.ON WATER SUPPLY
 BRANCH LINES PER SPC SEC.610.4.2.
  
 MAXIMUM OF 4 FIXTURES SHALL BE SUPPLIED
 BY 1/2" H.W.LINE PER COUNTYWIDE AMEND-
 MENTS TO SPC SEC.607.7. (SEE 4TH.FLR.
 RESTROOMS & CHECK ENTIRE RISER.)
  
 FLOOR DRAINS SHALL BE LOCATED TO BE IN
 FULL VIEW PER SPC SEC.409.4.1.2.
  
 SHOW LENGTHS OF ALL CUT SECTIONS OF NEW
 GAS PIPE.NOTE APPROPRIATE GAS SIZING
 CHART ON PLAN.SYSTEM SIZING SHALL BE
 FROM POINT OF DELIVERY(EXISTING)TO MOST
 REMOTE OUTLET PER SGC SEC.305.4, 305.6.
 1003.4.SUBMIT CALCULATIONS FOR SIZING.
  
 SHOW EMERGENCY SHUT-OFF VALVE FOR GAS
 SYSTEM PER NFPA 96, SEC.7-4.
  
 GAS EQUIPMENT SHUTOFF VALVES AND CONN-
 ECTIONS SHALL COMPLY W/NFPA 54,SEC.5.5.4

Review Stop P PLUMBING
Rev No 5 Status P Date 1999-09-02 Cont ID  
Sent By tlarge Date 1999-09-02 Time 12:32 Rev Time 2.50
Received By tlarge Date 1999-09-02 Time 12:32 Sent To  
Notes
2001-01-08 00:00:00APPROVED 2 SETS-3RD SET MISSING PLBG.
 SHEETS.

Review Stop P PLUMBING
Rev No 4 Status P Date 1999-09-02 Cont ID  
Sent By tlarge Date 1999-09-01 Time 11:30 Rev Time 1.50
Received By tlarge Date 1999-09-01 Time 11:30 Sent To  
Notes
2001-01-08 00:00:00HANDICAP ACCESSIBLE STALL DOOR SHALL
 COMPLY W/FACBC SEC.4.17.5,4.13.(DOOR
 FROM ONE STALL SWINGS INTO CLEAR WIDTH
 OF HANDICAP STALL.

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-09-02 Cont ID  
Sent By tlarge Date 1999-08-20 Time 12:40 Rev Time 4.75
Received By tlarge Date 1999-08-20 Time 12:40 Sent To  
Notes
2001-01-08 00:00:00SHT.A7.1-WOMEN'S R.R.-MIN.CLEARANCE FOR
 WHEELCHAIR IS 32" PER F.A.C.B.C. SEC.
 4.2.1.(SEE AREA AT ADDED H.C. STALL DOOR
 AND STALL PARTITION.)
  
 SHT.P.7-8" RWL IS DRAINING INTO 6" LINE.
 COMPLY W/SPC 307.5, TABLES 1108.1,
 108.2.
  
 SHT.P.8-SHOWER IN MEN'S ROOM NOT SHOWN
 ON RISER.SPC SEC.104.2.1.(SEE P.3,3RD.
 FLR.)
  
 SHT.P.8-(3RD.FLR.)-OVER 2 FIXTURES ON
 1/2" C.W.(SEE D.F.'S.)AMENDMENTS TO
 CODE SEC.607.7
  
 SHT.P.8-OVER 2 FIXTURES CONNECTED TO
 1/2"C.W.(SEE UPPER CAFE AREA)AMENDMENTS
 TO STANDARD PLBG.CODE SEC.607.7.(SEE
 P901,P902.)
  
 SHT.P.1-FLOOR DRAIN IN STORAGE ROOM
 EXCEEDS DISTANCE FROM VENT.COMPLY W/
 TABLE 908.1 OF SPC.

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-09-02 Cont ID  
Sent By tlarge Date 1999-07-30 Time 16:01 Rev Time 4.75
Received By tlarge Date 1999-07-30 Time 16:01 Sent To  
Notes
2001-01-08 00:00:00SHT A2.1-AN ADD'L.HANDICAP STALL IS
 REQ'D.IN ROOM#113 PER F.A.C.B.C.SEC.
 4.22.4.
  
 COMMON LAUNDRY AREAS SHALL COMPLY W/
 F.A.C.B.C. SEC.4.1.6.9 (1)(B),4.27.1.
  
 HANDICAP SHOWERS AND SEATS SHALL COMPLY
 W/F.A.C.B.C. SEC.4.21.2, 4.21.3.
  
 SHT.A7.2-ELEV.#8-HANDICAP URINAL SHALL
 COMPLY W/F.A.C.B.C.SEC.4.18.2 (MAX.17"
 A.F.F.)
  
 SHT.A7.3-ADDITIONAL H.C. STALL REQ'D.
 IN MEN'S AND WOMEN'S RESTROOMS PER
 F.A.C.B.C. SEC.4.22.4.**(NOTE:CHECK ALL
 RESTROOMS FOR THIS REQ'.)
  
 SHT.A7.3-ELEV.#19-H.C URINAL SHALL BE
 AT MAX.17" A.F.F.TO RIM PER F.A.C.B.C.
 SEC.4.18.2.
  
 FLOOR DRAINS SHALL NOT EXCCED DISTANCE
 FROM VENT PER SPC.SEC.908 & TABLE 908.1
  
 MAX.TEMPERATURE OF WATER DISCHARGED TO
 SANITARY SYSTEM SHALL NOT EXCEED 140
 DEGREES.SPC.SEC.807.3
  
 MAX.TEMPERATURE TO RESTROOMS SHALL NOT
 EXCEED 110 DEGREES PER FLA.ENERGY CODE
 SEC.412.ABCD.2.3.2.
  
 WATER SUPPLY CONTROL SHALL COMPLY W/SPC
 SEC.610.4.1, 610.4.2.
  
 FLOOR DRAINS ARE NOT PROPERLY VENTED.
 COMPLY W/SPC SEC.901.2, TABLE 908.1
  
 SUBMIT STORM RISER DIAGRAM FOR THE
 STORM DRAINAGE SYSTEM.SPC 104.2.1.
  
 SUBMIT MANUF.SHEETS FOR GASEQUIPMENT.
 EQUIPMENT SHALL BE LISTED PER STD.GAS
 CODE SEC.402.1.
  
 CLEARLY SHOW WATER SOURCE FOR IRRIGATION
 SYSTEM .BACKFLOW PREVENTION DEVICE IS
 REQ'D.IF ON CITY WATER.SPC 601.6
  
 EQUIPMENT SUPPLY LINES ON GAS HEADER ARE
 UNDERSIZED.COMPLY W.STD.GAS CODE SEC.
 305.2(INDICATE TYPE OF PIPING TO BE
 INSTALLED.)AND TABLES 305.4.
  
 SUBMIT CALCULATIONSFOR ROOF DRAINAGE
 OVERFLOW.COMPLY W/SBC SEC.1507.4.3,
 1604.6.2.,STD.PLBG.CODE SEC.1109.
  
 SUPPLY OCCUPANT LOAD AS DETERMINED BY
 SPC SEC.407.1.3 TO ENSURE COMPLIANCE
 FOR MINIMUM FIXTURE REQUIREMENTS.

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-09-02 Cont ID  
Sent By pschmitz Date 1999-06-26 Time 13:08 Rev Time 3.00
Received By tlarge Date   Time   Sent To  
Notes
2001-01-08 00:00:00UNSAT
 (1) COVER SHT.GIVE DETAILS OF OCCUPANCY
 & SQUARE FOOTAGE FOR EACH FLOOR AND
 NUMBER OF PEOPLE.
 (2) SHT.L-1 IRRIGATION LAYOUT AND
 LOCATION OF BACK FLOW PREVENTER.
 (3) SHT. P-2 SHOW 2ND FLOOR REST RM'S
 (4) SHT. P-6 ALL INDIRECT WASTE TO
 FLOOR SINKS NO HUB DRAINS.SPC CH 8.
 (5) SHT.P-8 GAS SOLENOID,A MANUAL
 SHUT OFF VALVE UP STREAM, UNION DOWN
 STREAM OF THE SOLENOID VALVE.SGC 508.2
 (6) SHT P-8 CK GAS PIPE SIZE ON HEADER,
 FOR BTU LOAD OF EACH APPLIANCE.
 "UNDER SIZED"
 END OF COMMENTS

Review Stop Z ZONING
Rev No 1 Status P Date 1999-09-03 Cont ID  
Sent By hpiskura Date 1999-07-09 Time 10:03 Rev Time 1.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy