Plan Review Details - Permit 99051064
Plan Review Stops For Permit 99051064
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-09-28 Cont ID  
Sent By lsmith Date 1999-09-28 Time 09:12 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:00RELOCATE HOUSE ON LOT OK GJ 9/27/99

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-14 Cont ID  
Sent By dpalmer Date 1999-06-14 Time 18:45 Rev Time 0.00
Received By dpalmer Date 1999-06-14 Time 18:45 Sent To  
Notes
2001-01-08 00:00:00PLANS SHOW NO A/C COND. UNIT.
 ALSO MISSING RECEPT.REQ`D FOR A/C EQUIP.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-06-19 Cont ID  
Sent By jleech Date 1999-06-19 Time 14:45 Rev Time 0.50
Received By jleech Date 1999-06-19 Time 14:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-08-07 Cont ID  
Sent By tlarge Date 1999-08-07 Time 08:03 Rev Time 0.33
Received By tlarge Date 1999-08-07 Time 08:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-08-07 Cont ID  
Sent By tlarge Date 1999-06-22 Time 15:06 Rev Time 0.65
Received By tlarge Date 1999-06-22 Time 15:05 Sent To  
Notes
2001-01-08 00:00:00SHOWER SHALL BE A MIN.OF 30" WIDE PER
 MODEL COUNTYWIDE AMEND.SEC.409.8.2.1.
  
 FIXTURES DOWNSTREAM OF WATER CLOSETS
 SHALL BE VENTED PER SPC SEC.913.2.
  
 SIZE VTR.FOR LAV.IN M.B.SPC.SEC.920.2
  
 MAX.2 W.C.'S PERMITTED ON 3" BUILDING
 DRAIN.SPC TABLE 714.1,FOOTNOTE#3.
  
 HORIZONTAL WET VENTS SHALL RECEIVE
 DISCHARGE FROM FIXTURE DRAINS ONLY PER
 MODEL COUNTYWIDE AMEND.SEC.911.1.1.
  
 ENERGY CALCS.SHOW CAPCITY OF EWH AS 30
 GAL.&PLANS SHOW 50 GAL.CLARIFY.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-07-21 Cont ID  
Sent By fknapp Date 1999-07-21 Time 15:21 Rev Time 5.00
Received By fknapp Date 1999-07-21 Time 08:27 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 1) PROVIDE CURRENT PRODUCT APPROVAL FOR
 ENTEGRRA ROOF TILE.
 2) PROVIDE SOIL REPORT
 CITY AMENDMENTS 104.2.2
 SUBMIT PRIOR TO FIRST INSPECTION
 PROVIDE RECIEPT OF PAID IMPACT FEES
 WILL OWE RADON AND ADDITIONAL PERMIT FEE

Review Stop Z ZONING
Rev No 1 Status P Date 1999-06-01 Cont ID  
Sent By gjoyce Date 1999-06-01 Time 16:09 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***