Plan Review Details - Permit 99050882
Plan Review Stops For Permit 99050882
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-11 Cont ID  
Sent By dpalmer Date 1999-06-11 Time 21:45 Rev Time 0.00
Received By dpalmer Date 1999-06-11 Time 21:45 Sent To  
Notes
2001-01-08 00:00:00*************PROVISO********************
  
 NEED AIC RATING SUBMITTED ON PLANS.
 ART.215-5
 NOTE:GROUNDING ELECTRODE CONDUCTOR TO
 BLDG.STEEL ALSO.
  
 NEED THE ABOVE BEFORE ROUGH INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 1999-07-21 Cont ID  
Sent By ndenmark Date 1999-07-21 Time 08:45 Rev Time 0.25
Received By ndenmark Date 1999-07-21 Time 08:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-07-21 Cont ID  
Sent By jleech Date 1999-06-19 Time 12:46 Rev Time 0.50
Received By ndenmark Date 1999-06-19 Time 12:46 Sent To  
Notes
2001-01-08 00:00:00SUBMIT MANUFACTORS SPECIFICATIONS FOR
 AIR HANDLER CFM CAPACITY.

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-12-21 Cont ID  
Sent By tlarge Date 1999-12-21 Time 09:31 Rev Time 0.30
Received By tlarge Date 1999-12-21 Time 09:31 Sent To  
Notes
2001-01-08 00:00:00REVISED GAS DRAWING.

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-07-19 Cont ID  
Sent By tlarge Date 1999-06-19 Time 12:02 Rev Time 0.50
Received By tlarge Date 1999-07-19 Time 16:49 Sent To  
Notes
2001-01-08 00:00:00A GAS PERMIT AND DRAWING IS REQ'D.THAT
 CLEARLY REFLECTS THE ENTIRE SCOPE OF
 WORK TO BE PERFORMED.SPC SEC.104.1.1 ,
 104.2.1, 104.3.1.

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-07-19 Cont ID  
Sent By tlarge Date 1999-06-19 Time 11:57 Rev Time 0.50
Received By tlarge Date 1999-06-19 Time 11:57 Sent To  
Notes
2001-01-08 00:00:00MAX.OF 2 W.C.'S PERMITTED ON 3" BUILDING
 DRAIN.S.P.C TABLE 714.1
  
 REMOVE TRAPS FROM WATER CLOSETS.S.P.C.
 1001.8.1
  
 WASHING MACHINE TRAP SHALL BE PROTECTED
 PER S.P.C. SEC.901.2
  
 SUBMIT ONE SAN.RISER DIAGRAM THAT COM
 COMPLIES W/STANDARD PLBG.CODE.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 1999-09-23 Cont ID  
Sent By jgomez Date 1999-09-23 Time 11:12 Rev Time 30.00
Received By jgomez Date 1999-09-23 Time 11:12 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-REVISE ORIGINAL DRAWING SHOWING THE
 CORRECTION OF WINDOW SIZES TO COMPLY
 WITH SEC. 1203.1 SBC 1994.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-07-19 Cont ID  
Sent By jcaloger Date 1999-07-19 Time 10:40 Rev Time 0.00
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-05-25 Cont ID  
Sent By gjoyce Date 1999-05-25 Time 11:18 Rev Time 0.00
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***