Plan Review Details - Permit 99050869
| Plan Review Stops For Permit 99050869 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-06-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-06-11 |
Time |
20:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-06-11 |
Time |
20:55 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************PROVISO***************** | | | | | | NEED CALCULATIONS DONE FOR AIC RATING | | | WHICH NEEDS TO BE DRAWN ON PANEL SCHD. | | | ART.215-5 | | | NEED RISER DIAGRAM TO SHOW GROUNDING | | | ELECTRODE CONDUCTOR DRAWN TO GROUND ROD, | | | C.W.P.,AND BLDG.STEEL.215-5 | | | NOTE:NEED EQUIPMENT GROUNDING COND. | | | DRAWN ON PLANS FROM MAIN DISC.TO | | | PANEL AND FROM PANEL TO OTHER DISC.S | | | 250-92/250-95 | | | NOTE:SMOKE DETECTORS REQ`D INSIDE | | | AND OUTSIDE BEDROOMS. | | | NOTE:RECEPTS.SERVING KITCHEN COUNTER | | | TOPS ARE TO BE DRAWN GFI/GFI PROTECTED. | | | ART.210-8-A-6 | | | NOTE:MASTER BEDROOM HALL 210-52H | | | NOTE:2`6`12`RULE 210-52A | | | | | | NEED TO SUBMIT BEFORE ROUGH INSPECTION!! |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-07-19 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-07-19 |
Time |
14:03 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
1999-06-21 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-06-21 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
tlarge |
Date |
1999-06-21 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | COMPLETE GAS DRAWING REQ'D.FOR | | | INSTALLATION OF ALL GAS EQUIPMENT. | | | STANDARD GAS CODE SEC.104.2.1 | | | | | | GAS WTR.HEATER SHALL BE PROTECTED FROM | | | PHYSICAL DAMAGE PER STD.GAS CODE SEC. | | | 402.7.2. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-07-19 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-06-21 |
Time |
16:00 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
1999-06-21 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | REMOVE TRAPS FROM WATER CLOSETS ON SAN. | | | ISOMETRIC.SPC SEC.1001.6,1001.8. | | | | | | SIZE ALL SECTIONS OF THE DWV SYSTEM. | | | SPC 104.2.1. | | | | | | MAX.2 WATER CLOSETS PERMITTED ON 3" | | | BUILDING DRAIN.SPC TABLES 714.1,FOOTNOTE | | | #3,TABLE 714.2,FOOTNOTE #2. | | | | | | MIN.SIZE OF BLDG.SEWER SHALL BE 4" PER | | | SPC TABLE 714.1,FOOTNOTE#2. | | | | | | MIN.SIZE OF U/G SAN.DRAINAGE SHALL BE | | | 2".SPC 714.4. | | | | | | "S-TRAP" ON KIT.SINK NOT PERMITTED PER | | | SPC SEC.101.5.2.,901.2. | | | | | | TUBS NOT PROPERLY VENTED.SPC 901.2. | | | | | | WET VENTS SHALL RECEIVE DISCHARGE FROM | | | FIXTURE DRAINS ONLY.COUNTYWIDE AMEND.TO | | | STANDARD PLBG.CODE SEC.911.1.1. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
1999-07-19 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-07-19 |
Time |
11:19 |
Rev Time |
3.00 |
| Received By |
fknapp |
Date |
1999-07-19 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-05-25 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-05-25 |
Time |
11:13 |
Rev Time |
|
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|