Plan Review Details - Permit 99050548
| Plan Review Stops For Permit 99050548 |
| Review Stop |
|
|
| Rev No |
1 |
Status |
N |
Date |
1999-07-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-08-11 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
fknapp |
Date |
1999-07-26 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
1999-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-07-15 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-07-15 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
1999-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-06-11 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-06-11 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***********DENIED****6-11-99*********** | | | | | | NEED TO SUBMIT PLANS WITH THE FOLLOWING! | | | 1)TOTAL RISER DIAGRAM TO INCLUDE ALL | | | OF THE FOLLOWING. | | | METER,MAIN DISC.(IF ONE IS BEING USED), | | | PANEL,ALL CONDUITS BETWEEN,ALL WIRE | | | SIZES. | | | 2)NEED TO HAVE LOAD CACULATIONS DONE | | | AND DRAWN ON PLANS. | | | 3)NEED PANEL SCHD.WITH AIC RATING | | | DRAWN IN. | | | 4)NEED FAULT CURRENT CALCULATIONS DONE | | | FOR AIC RATING. | | | 5)GROUNDING ELECTRODE SYSTEM ON RISER | | | DIAGRAM.CONDUCTOR TO GRND.ROD,CWP+ | | | BLDG.STEEL. | | | ALL THE ABOVE INFORMATION IS REQ`D BY | | | ART.215-5 | | | NOTE:ALSO RECEPT.REQ`D FOR A/C COND. | | | UNIT 210-63 | | | NOTE:2`6`12` ART.210-52A | | | | | | NEED ALL THE ABOVE INFORMATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-06-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
1999-06-12 |
Time |
14:50 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
1999-06-12 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
1999-08-11 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-08-11 |
Time |
09:29 |
Rev Time |
0.25 |
| Received By |
tlarge |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-07-23 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-06-18 |
Time |
17:28 |
Rev Time |
0.65 |
| Received By |
tlarge |
Date |
1999-06-18 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BIDET DOWNSTREAM OF W.C SHALL BE VENTED. | | | STANDARD PLBG.CODE SEC.913.2. | | | | | | MAX.2 WATER CLOSETS PERMITTED ON 3" BLDG | | | DRAIN.STANDARD PLBG.CODE SEC.AND TABLE | | | 714.1. | | | | | | MIN.SIZE OF WATER CLOSET DRAIN SHALL BE | | | 3".S.P.C.SEC-& TABLE 713.1,714.1, | | | FOOTNOTE #1. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
1999-07-26 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-07-26 |
Time |
09:55 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
1999-07-26 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | CITY AMENDMENTS 104.2.2 | | | 1) PROVIDE PRODUCT APPROVAL EXTERIOR | | | ENTRY SWING DOORS. | | | 2) PROVIDE PRODUCT APPROVAL FOR ARCH | | | TRANSOMS. | | | SUBMIT PRIOR TO INSTALLATION. | | | | | | CITY AMENDMENTS 1606.4 AND 1707.4 | | | 1) PROVIDE MISSILE IMPACT RESISTANCE | | | INFORMATION,UNDER SEPERATE PERMIT. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
1999-07-26 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-07-15 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
fknapp |
Date |
1999-07-26 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED SEE CHECKLIST 7/15/99/FK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-05-18 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-05-18 |
Time |
11:01 |
Rev Time |
|
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|