Plan Review Details - Permit 99050123
Plan Review Stops For Permit 99050123
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-11 Cont ID  
Sent By dpalmer Date 1999-06-11 Time 10:12 Rev Time 0.00
Received By dpalmer Date 1999-06-11 Time 10:12 Sent To  
Notes
2001-01-08 00:00:00****************PROVISO*****************
  
 SUBMIT! NEW PANEL SCHEDULE SHOWING
 AIC RATING.215-5
 PLEASE HAVE BEFORE ROUGH INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-06-12 Cont ID  
Sent By jleech Date 1999-06-12 Time 08:24 Rev Time 0.50
Received By jleech Date 1999-06-12 Time 08:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-07-07 Cont ID  
Sent By tlarge Date 1999-07-07 Time 15:26 Rev Time 0.33
Received By tlarge Date 1999-07-07 Time 15:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 1999-06-26 Cont ID  
Sent By tlarge Date 1999-06-26 Time 11:41 Rev Time 0.25
Received By tlarge Date 1999-06-26 Time 11:41 Sent To  
Notes
2001-01-08 00:00:00FIXTURES DOWNSTREAM OF W.C.'S SHALL BE
 VENTED PER SPC SEC.913.2.
  
 CLARIFY TYPE OF VENT ON KIT.SINK.(CODE
 DOESN'T ADDRESS "ISLAND STUDOR VENT")

Review Stop P PLUMBING
Rev No 1 Status F Date 1999-06-12 Cont ID  
Sent By jleech Date 1999-06-12 Time 08:25 Rev Time 0.50
Received By jleech Date 1999-06-12 Time 08:24 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 1999-09-24 Cont ID  
Sent By jgomez Date 1999-09-24 Time 13:40 Rev Time 0.50
Received By jgomez Date 1999-09-24 Time 13:40 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-FOOTING F1 WAS NOT REVISED. SOIL TEST
 REPORT REQUIRED A FOOTING WIDTH OF 18"
 TO 34".
 2-CONNECTION OF A GARAGE WITH ANY ROOM
 WITH A GAS APPLIANCE SHALL BE BY MEANS
 OF A DOORWAY WITH A RAISED SILL AT
 LEAST 8" ABOVE THE GARAGE FLOOR.
 SECTION 411.2.7 SBC 1994.
 3-PROVIDE SPECIFICATIONS TO COMPLY WITH
 SECTION 402.7 SGC 1994 FOR INSTALLATION
 OF GAS APPLIANCES IN GARAGE.
 4-ENTRY DOORS TO BE 32" MINIMUM CLEAR.
 TABLE 1004 SBC 1994.
 5-SPECIFY SIZE OF CEILING FANS AS PER
 TABLE 6-6 OF FLORIDA ENERGY CODE 1997
 AND AS PER CREDIT TAKEN IN ENERGY CALCS
 6-REVISE SPECIFICATION FOR INSULATION IN
 ATTIC. IT SHOULD BE R-30 AS PER ENERGY
 CALCULATIONS. SEE SHEET A5, SECTION AA.
 7-PROVIDE CONNECTION DETAILS. SEE SHEET
 FOR COMMENTS
 8-SEE COMMENTS ON ALL PLANS.
  
 NOTE:
 PLEASE CLOUD ALL REVISIONS IN ORDER TO
 EXPEDITE THE REVIEW PROCESS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-07-08 Cont ID  
Sent By jgomez Date 1999-07-08 Time 16:53 Rev Time 2.00
Received By jgomez Date   Time   Sent To O
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO

Review Stop Z ZONING
Rev No 1 Status P Date 1999-05-05 Cont ID  
Sent By gjoyce Date 1999-05-05 Time 17:08 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***