Plan Review Details - Permit 99050113
Plan Review Stops For Permit 99050113
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date   Cont ID  
Sent By tlarge Date 1999-06-18 Time 09:22 Rev Time  
Received By tlarge Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 1999-09-28 Cont ID  
Sent By dpalmer Date 1999-09-28 Time 06:57 Rev Time 0.00
Received By dpalmer Date 1999-09-28 Time 06:57 Sent To  
Notes
2001-01-08 00:00:00***********UNSAT********************
  
 1)NOTE: NEED TO SUBMIT AIC RATING
 FIGURED FROM FAULT CURRENT CALCUULATIONS
 ARTS;110-9/215-5
 AIC RATING SHOULD BE LISTED ON ALL
 PANEL SCHEDULES FROM HERE ON OUT.
 2) NOTE:PLEASE INCLUDE EQUIPMENT GROUND
 AS REQ`D BY CODE FROM MAIN DISC.TO
 PANEL.SIZED FROM ART;250-95

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 1999-07-06 Cont ID  
Sent By ndenmark Date 1999-07-06 Time 13:19 Rev Time 0.25
Received By ndenmark Date 1999-07-06 Time 13:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-07-06 Cont ID  
Sent By jleech Date 1999-06-12 Time 12:41 Rev Time 0.50
Received By ndenmark Date 1999-06-12 Time 12:41 Sent To  
Notes
2001-01-08 00:00:00A/C PLAN SHOWS 2250CFM A/H CAN SUPPLY
 2000CFM.

Review Stop P PLUMBING
Rev No 2 Status F Date 1999-09-29 Cont ID  
Sent By tlarge Date 1999-09-29 Time 07:38 Rev Time 0.50
Received By tlarge Date 1999-09-29 Time 07:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 1999-06-18 Cont ID  
Sent By tlarge Date 1999-06-18 Time 12:18 Rev Time 0.50
Received By tlarge Date 1999-06-18 Time 12:18 Sent To  
Notes
2001-01-08 00:00:00TRAPS FOR TUB AND SHOWER IN GUEST BATH
 EXCEED PERMITTED DISTANCES FROM VENT PER
 STANDARD PLBG.CODE SEC.908.1
  
 LAYOUT OF GUEST BATH ON SAN.ISOMETRIC
 DOESN'T CORRELATE W/FLOOR PLAN.
 STANDARD PLBG.CODE.104.2.1.
  
 REMOVE LOOP VENT FROM KIT.SINK.AND SHOW
 STUDOR VENT.
  
 MAIN VENT REQD.THRU ROOF PER SPC SEC.
 904.3.1.
  
 GAS APPLIANCE IN GARAGE SHALL BE
 PROTECTED FROM PHYSICAL DAMAGE PER STD.
 GAS CODE SEC.402.7.

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***