Plan Review Details - Permit 99050066
Plan Review Stops For Permit 99050066
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-06-25 Cont ID  
Sent By bstaples Date 1999-06-25 Time 13:54 Rev Time 3.00
Received By bstaples Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-30 Cont ID  
Sent By bstaples Date 1999-06-25 Time 13:55 Rev Time 0.00
Received By bstaples Date 1999-06-30 Time 14:51 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 1999-06-25 Cont ID  
Sent By bstaples Date 1999-06-25 Time 13:56 Rev Time  
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE NOTES ON APPLICATION FROM ENG.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-06-25 Cont ID  
Sent By bstaples Date 1999-06-25 Time 13:56 Rev Time  
Received By bstaples Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-08-22 Cont ID  
Sent By pschmitz Date 2000-08-22 Time 09:30 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-01-08 00:00:00PLUMBING PLAN REVIEW DENIED
 (1)SHT P-1 SPACE WITH KITCHEN SINK,
 SPC 94 TAB 407 REQ. ADDITONAL 1 W/C,1LAV
 ALL REST RM'S TO BE H/C ACCESSIBLE.
 END OF COMMENTS
 QUESTIONS PAUL SCHMITZ 659-8096

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-06-30 Cont ID  
Sent By tlarge Date 1999-06-30 Time 14:06 Rev Time 1.00
Received By tlarge Date 1999-06-23 Time 14:05 Sent To  
Notes
2001-01-08 00:00:00SUBMIT CIVIL DRWGS.AS NOTED ON SHT.P-1
 THAT CLEARLY SHOW CONNECTION OF SANITARY
 AND WATER LINES TO CITY UTILITIES.
 SPC SEC.104.2.1,104.3.1.
  
 SHT.A-2 SHOWS ROOF DRAINS-SUBMIT STORM
 WATER RISER FOR REVIEW.SUPPLY SQ.FT.AREA
 DRAINED BY EACH DRAIN,PIPE SIZES,SLOPE
 OF PIPE,TERMINATION PT.,ETC. SPC.SEC.
 1101.2.TYPE OF PIPING SHALL COMPLY W/SPC
 SEC.1103.4, 1104.
  
 SUBMIT PROVISIONS FOR SECONDARY DRAINAGE
 OF ROOF AREA WHERE ROOF DRAINS ARE
 LOCATED. SPC SEC.1109.1
  
 SLOPE OF SANITARY SYSTEM SHALL COMPLY
 W/SPC SEC.705.2,705.3.(SEE NOTE #8 ON
 SHT.P.1.)
  
 SHT.P.1-NOTE #11-"M" COPPER NOT
 PERMITTED BELOW GROUND PER COUNTYWIDE
 AMENDMENTS SEC.611.3.
  
 SHT.P.1-NOTE #16 REFERS TO GAS.SUBMIT
 PLANS FOR GAS IF APPLICABLE.IF NO GAS
 DELETE NOTEFROM PLAN.
  
 SHT.P1-MIN.DISTANCE BETWEEN BUILDING
 DRAIN /SEWER AND WATER SERVICE SHALL
 COMPLY W/SPC SEC.608.3
  
 CONDENSATE DRAINS SHALL DISCHARGE PER
 STD,MECH.CODE SEC.304.8.3 & COUNTYWIDE
 AMENDMENTS TO SPC.SEC.804.3.
  
  
 ****************PROVISO*****************
 SECONDARY DRAINAGE PROVISIONS SHALL BE
 PROVIDED FOR LOW ROOF AREA AND COMPLY W/
 STANDARD BUILDING CODE SECS.1507.4.1,
 THRU 1507.4.3, 1604.6.2(1-4),AND
 STANDARD PLUMBING CODE SEC.1109.1,
 1109.2, 1109.3.
  
 PLANS AND RISER DIAGRAM REQ'D.PRIOR TO
 RGH.PLBG.INSP.6/30/99.

Review Stop Z ZONING
Rev No 1 Status P Date 1999-06-07 Cont ID  
Sent By gjoyce Date 1999-06-07 Time 15:35 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00DUMPSTER LOCATED IN EASEMENT