Plan Review Details - Permit 99041258
Plan Review Stops For Permit 99041258
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-09 Cont ID  
Sent By dpalmer Date 1999-06-09 Time 19:17 Rev Time 0.00
Received By dpalmer Date 1999-06-09 Time 19:17 Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
  
 NOTE:NEED NEUTRAL LOAD CALCULATIONS
 BEING THAT NEUTRAL COND.IS DOWNSIZED.
 NOTE:GROUNDING ELECTRODE CONDUCTOR
 TO BLDG.STEEL ALSO.
 NOTE:REQ`D GFI RECEPT.210-63
 NOTE:2`6`12`RULE 210-52A
  
 NEED THE ABOVE INFORMATION BEFORE ROUGH
 INSPECTION IS CALLED IN.
 NOTE:NEED FAULT CURRENT CALCULATIONS
 FOR AIC RATING.215-5

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-06-12 Cont ID  
Sent By jleech Date 1999-06-12 Time 07:33 Rev Time 0.50
Received By jleech Date 1999-06-12 Time 07:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-08-11 Cont ID  
Sent By tlarge Date 1999-08-11 Time 09:02 Rev Time 0.25
Received By tlarge Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-06-28 Cont ID  
Sent By pschmitz Date 1999-06-14 Time 14:47 Rev Time 0.50
Received By tlarge Date 1999-06-14 Time 14:47 Sent To  
Notes
2001-01-08 00:00:00SHOW ALL FIXTURE CLEARANCES PER SPC SEC.
 403.4
  
 WATER CLOSET & BIDET IN MASTER BATH ARE
 NOT PROPERLY VENTED.SPC SEC.901.2.
  
 LAYOUT OF BATH#2 & MASTER BATH ON SAN.
 RISER DOESN'T CORRELATE W/FLOOR PLAN ON
 SHT.#3.SPC SEEC.104.2.1.
  
 ONLY 2 WATER CLOSETS PERMITTED ON 3"
 BUILDING DRAIN.SPC TABLE 714.1 FOOTNOTE
 #3.
  
 ****************NOTE********************
 COMPLY W/ALL PREVIOUS LISTED COMMENTS
 DATED 6/14/99.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-06-28 Cont ID  
Sent By jcaloger Date 1999-06-24 Time 09:42 Rev Time  
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-05-04 Cont ID  
Sent By gjoyce Date 1999-05-04 Time 10:52 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***