Plan Review Details - Permit 99040666
Plan Review Stops For Permit 99040666
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-04 Cont ID  
Sent By dpalmer Date 1999-06-04 Time 18:04 Rev Time  
Received By dpalmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00****************PROVISO****************
  
 NOTE:GROUNDING ELECTRODE SYSTEM IS GO
 FROM METER CAN TO GRND.ROD,CWP,AND
 BLDG.STEEL.250-81/250-94
 NOTE:NEED FAULT CURRENT CALCULATIONS
 FOR AIC RATING OF EQUIP.215-5
 NOTE:SMOKE DETECTORS REQ`D INSIDE AND
 OUTSIDE BEDROOMS.
  
 NEED THE ABOVE INFORMATION BEFORE FINAL.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-06-04 Cont ID  
Sent By ndenmark Date 1999-06-04 Time 08:50 Rev Time 0.25
Received By ndenmark Date 1999-06-04 Time 08:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-06-05 Cont ID  
Sent By pschmitz Date 1999-06-05 Time 10:38 Rev Time 0.50
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-06-30 Cont ID  
Sent By jcaloger Date 1999-06-09 Time 15:29 Rev Time 40.00
Received By jcaloger Date   Time   Sent To  
Notes
2001-01-08 00:00:00SOIL REPORT NEEDS SEAL & REFER CWPB
 PRODUCT APPROVAL EXPIRED
 PLAN A2 NEEDS TE1 DIMENSIONS
 ROOF NAILING NOT COMPLY WITH TABLE 2306

Review Stop Z ZONING
Rev No 1 Status P Date 1999-04-22 Cont ID  
Sent By gjoyce Date 1999-04-22 Time 15:48 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***