Plan Review Details - Permit 99040392
Plan Review Stops For Permit 99040392
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-09-01 Cont ID  
Sent By lmartine Date 1999-05-26 Time 14:19 Rev Time 0.50
Received By sgraham Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK BY L SMITH 9/1/99

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2001-09-12 Cont ID  
Sent By dpalmer Date 2001-09-12 Time 12:19 Rev Time 0.00
Received By dpalmer Date 2001-09-12 Time 12:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2001-07-19 Cont ID  
Sent By dpalmer Date 2001-07-19 Time 17:24 Rev Time 0.00
Received By dpalmer Date 2001-07-19 Time 17:24 Sent To  
Notes
2001-07-19 00:00:00***************** UNSAT ***************
  
 PLEASE NOTE THAT THESE NOTES ARE IN
 RESPONSE TO LETTER FROM MR. GEORGE PEREZ
  
  
 1)NOTE: RESPONSE TO NOTE#2 PLEASE NOTE
 THAT NO PANEL SCHEDULES WERE SUBMITTED??
 PLEASE ALSO NOTE THAT THERE IS NOTHING
 IN THE NEC OR LOCAL AMENDMENTS THAT DOES
 NOT ALLOW #14AWG IN COMMERCIAL BLDG`S.
  
 2)NOTE: IN RESPONSE TO NOTE #5 PLEASE
 NOTE THAT HABITABLE ROOMS NEED TO SHOW
 LIGHT FIXTURES. SOME ROOMS IN APTS STILL
 SHOW "JB'S" WHER LTS SHOULD BE SHOWN.
 210-70
  
 3)NOTE: IN RESPONSE TO NOTE# 6. NO PANEL
 SCHEDULES??
  
 4)NOTE: IN REPSONSE TO NOTE #8; FIRST
 SET OF NOTES REFER TO LOCAL AMENDMENT
 210-50 REQ`S OUTLETS EVERY 20`.
  
 5)NOTE: IN RESPONSE TO NOTE# 6; PLEASE
 NOTE THAT NO BRANCH CIRCUIT #`S ARE
 SHOWN ON PLANS AND NO PANEL SCHEDULE TO
 CORRELATE? PLEASE SUBMIT.
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2001-03-13 Cont ID  
Sent By dpalmer Date 2001-03-13 Time 06:30 Rev Time 0.00
Received By dpalmer Date 2001-03-13 Time 06:30 Sent To  
Notes
2001-03-13 00:00:00****************UNSAT *****************
  
 PLEASE NOTE: ELECTRCIAL PLANS ARE JUST
 NOW BEING SUBMIITED FOR REVIEW. PLEASE
 SEE THE FOLLOWING NOTES.
  
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG. FOR ALL APTS.
  
 3) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
  
 4) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.1
 MECHANICAL CODE. PLEASE SHOW
 CLARIFICATION.
  
 5) PLEASE NOTE EITHER MISSING EGRESS
 LIGHTING AND/OR CLARIFY EGRESS LIGHTING
 PER 210-70 OF THE NEC.
 YOU SHOW JB IN LOCATIONS OF WHICH MEANS
 OF EGRESS LIGHTING IS REQ`D.
  
 6)NOTE: PLANS NEED TO SHOW ALL BRANCH
 CIRCUIT #`S ON PLANS. THESE NEED TO
 CORRELATE WITH PANEL SCHEDULES. NEED TO
 SUBMIT PANEL SCHEDULES FOR ALL PANELS.
 PLANS ARE COMING IN AS "AS-BUILTS" ??
  
 7)NOTE: PLEASE NOTE PER 210-8 RECEPTS
 SHOWN IN BATHROOMS DOWNSTAIRS NEED TO
 BE SHOWN AS GFI/GFI PROTECTED.
  
 8)NOTE: PLEASE NOTE OUTLET SPACING TO
 MEET LOCAL AMENDMENTS OF ART 210-50.
 UPSTAIRS HALLWAYS.
  
 9)NOTE: PLEASE SHOW LOCATIONS OF AHU`S.
  
 11)NOTE:PLEASE LABEL APARTMENTS ON E-
 SHEETS.
  
 12)NOTE: PLEASE SEE TWO SWITCHES IN
 REARAPT IN BEDROOM? GOING TO ???
  
 13)NOTE: PLEASE SEE 553-79-6A F.A.C.
 REQUIRES SERVICES ON COMMERCIAL
 PRODJECTS OF 800A OR MORE TO BE SIGNED
 AND SEALED BY AN ENGINEER PER 471.025
  
 PLEASE ADDRESS ALL OF THE ABOVE COMMENTS
 AND SUBMIT FOR REVIEW. IF THERE ARE ANY
 QUESTIONS PERTAINING TO ANY OF THE ABOVE
 PLEASE CALL FOR CLARIFICATION.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-01-11 Cont ID  
Sent By dpalmer Date 2001-01-11 Time 11:59 Rev Time 0.00
Received By dpalmer Date 2001-01-11 Time 11:59 Sent To  
Notes
2001-01-11 00:00:00************* UNSAT **********
  
 1)NOTE: PLEASE ADDRESS ORIG NOTES FROM
 6/25/99. PLEASE HAVE ORIG ENGINEER OF
 RECORD EITHER ADDRESS PLANS OR RELEASE,
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-25 Cont ID  
Sent By jleahy Date 1999-06-25 Time 11:34 Rev Time 1.00
Received By dpalmer Date 1999-05-18 Time 11:34 Sent To  
Notes
2001-01-08 00:00:00NO ELECTRIC SHOWN, NEEDS ELECTRICAL
 DRAWINGS
  
 6/25/99******PROVISO***********
 NEED TO DRAW IN ALL SWITCH LEGS FOR
 LIGHTING SWITCHES.
 NOTE:RECEPTS.REQ`D 210-52
 NOTE:EGRESS LIGHTING.210-70

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-05-20 Cont ID  
Sent By bprusiec Date 1999-05-20 Time 09:11 Rev Time  
Received By bprusiec Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 1999-09-01 Cont ID  
Sent By ndenmark Date 1999-08-27 Time 12:57 Rev Time 0.33
Received By sgraham Date 1999-08-27 Time 12:57 Sent To  
Notes
2001-01-08 00:00:00CONTRQCTOR TO BRING A/C PLANSNCD

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-09-01 Cont ID  
Sent By ndenmark Date 1999-06-28 Time 08:43 Rev Time 0.33
Received By sgraham Date 1999-06-28 Time 08:43 Sent To  
Notes
2001-01-08 00:00:00**************DENIED********************
 1) NO OUTSIDE AIR CALCULATIONS SHOWN PER
 ASHRAE 62-89
 2) 2ND FL APTS A/CSUPPLY SHALL NOT
 SERVE THE COMMON CORRIDOR PER 1994 SMC
 609.1.1
 3) PROVIDE INFORMATION ON BATHROOM EX-
 HAUST FANS AND VENT DUCT FOR THE SECOND
 FLOOR
 4) DRYER VENT TO COMPLY WITH 1994 SMC
 509.1, 509.2 AND 509.4 COMMERCIAL EX-
 HAUST AND SHALL NOT BE IN RATED WALL

Review Stop P PLUMBING
Rev No 4 Status F Date 2001-03-13 Cont ID  
Sent By jleech Date 2001-03-13 Time 17:11 Rev Time 1.50
Received By jleech Date 2001-03-13 Time 17:10 Sent To  
Notes
2001-03-13 00:00:00DENIED;
  
 1.KITCHEN SINK REQUIRED IN APARTMENTS.
 94 SPC 401.2.1
  
 2.A-2 UTILITY ROOM WATER HEATER SHOWS
 GAS. SHEET E-1 SHOWS ELECTRIC.IS IT
 GAS OR ELECTRIC?
  
 3.SHOW A WATER RISER DIAGRAM.
  
 4.SHOW A SANITARY RISER DIAGRAM FOR NEW
 FIXTURES ADDED ON 2ND FLOOR.
  
 5.WHAT TYPE OF PIPE WILL BE USED? WATER
 AND DWV.
  
 6.SPECIFY HANDICAP FIXTURES TO BE USED
 IN HANDICAP BATHROOMS.

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-08-31 Cont ID  
Sent By tlarge Date 1999-08-31 Time 09:48 Rev Time 0.65
Received By tlarge Date 1999-08-31 Time 09:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-08-31 Cont ID  
Sent By tlarge Date 1999-08-17 Time 12:24 Rev Time 1.25
Received By tlarge Date 1999-08-17 Time 12:24 Sent To  
Notes
2001-01-08 00:00:00SUBMIT COMPLETE GAS RISER DIAGRAM THAT
 CLEARLY REFLECTS ENTIRE SCOPE OF WORK
 BEING DONE.STD.GAS CODE SEC.302.
 (SHOW TYPE OF PIPE,BTU LOAD,SUPPLY
 PRESSURE,LOCATION OF METER,ETC.)
  
 SUBMIT COMPLETE WATER AND SANITARY
 RISERS THAT CLEARLY SHOW SCOPE OF NEW
 PLBG.WORK BEING DONE.SPC 104.2.1.
  
 PROVIDE CALCS.FOR COMBUSTION AIR FOR
 GAS WTR.HTR.COMPLY W/STD.GAS CODE SEC.
 402.

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-08-31 Cont ID  
Sent By pschmitz Date 1999-05-22 Time 14:04 Rev Time 0.75
Received By tlarge Date   Time   Sent To  
Notes
2001-01-08 00:00:00UNSAT: PROVIDE ISOMETRIC FOR DWV AND
 WATER LINES ALSO LOCAION OF WATER
 HEATER'S.PES
 READ-- NOTES:UNSAT.06-26-99 2ND TIME
 APPLIES TO ALL NEW PLUMBING WORK.PES

Review Stop Z ZONING
Rev No 1 Status P Date 1999-04-15 Cont ID  
Sent By gjoyce Date 1999-04-15 Time 08:18 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***