Plan Review Details - Permit 99040251
Plan Review Stops For Permit 99040251
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 1999-11-22 Cont ID  
Sent By jgomez Date 1999-11-22 Time 17:57 Rev Time 1.00
Received By jgomez Date 1999-11-22 Time 17:56 Sent To  
Notes
2001-01-08 00:00:00PRODUCT APPROVALS CHECKLIST:
 1-APARTMENT ENTRY DOORS:
 A) DOORS MUST BE LABELED WITH THE
 REQUIRED FIRE RATING (20 MINUTES).
 SEC. 705.1.3.2 SBC 1994.
 B) DOORS SHALL BE SELF-CLOSING.
 SEC. 705.1.3.2.3 SBC 1994.
  
 2-ALUMINUM SINGLE HUNG WINDOW PRODUCT
 APPROVAL IS MISSING PAGE 2C.
  
 3-ALUMINUM TUBE MULLION PRODUCT APPROVAL
 REQUIRES ARCHITECT OR ENGINEER TO
 SELECT THE PROPER MULLION CHART AND
 ANCHORS WHICH MEET OR EXCEED THE
 DESIGN LOADING CONDITIONS.
 SEE NOTE #3 OF GENERAL NOTES OF DADE
 COUNTY APPROVED DRAWINGS.
  
 4-ALL SUBMITTALS TO BE REVIEWED BY
 ENGINEER AND ARCHITECT OF RECORD
 RESPECTIVELY, PRIOR TO SUBMITTAL TO
 THIS OFFICE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 1999-11-10 Cont ID  
Sent By jgomez Date 1999-11-10 Time 16:11 Rev Time 1.00
Received By jgomez Date 1999-11-10 Time 16:11 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST FOR MISSILE IMPACT DOORS AND
 WINDOWS PRODUCT APPROVALS:
 1-PRODUCT APPROVAL FOR OUTSWING,INSWING,
 INSWING/OUTSWING EXTERIOR DOORS.
 A)NEED TO BE REVIEWED AND APPROVED BY
 THE ENGINEER OF RECORD ON THIS PROJECT
 AND COMPLETE ALL INFORMATION ON
 SECTION 9.0 OF PRODUCT APPROVAL FORM.
 B)CLARIFY WHY LINE D) OF SECTION 4.2
 DOESN'T CONSIDER THE BUCK TO BE
 STRUCTURAL.
 C)PROVIDE COPIES OF THE TESTS PERFORMED
  
 2-DRAWINGS FOR SLIDING GLASS DOORS ARE
 NOT LEGIBLE.
  
 3-PRODUCT APPROVAL FOR MISSILE IMPACT
 WINDOWS MULLED TOGETHER WITH DADE
 COUNTY PRODUCT APPROVAL FOR MULLIONS
 IS NOT ACCEPTABLE.
 NEED TO PROVIDE A COMPLETE ENGINEERING
 ANALYSIS AND COPIES OF TESTS FOR
 MISSILE IMPACT ASSEMBLY OF WINDOWS
 MULLED TOGETHER OR DADE COUNTY PRODUCT
 APPROVAL FOR THIS ASSEMBLY.
  
 4-PROVIDE 3 COPIES OF EACH SUBMITTAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 1999-11-02 Cont ID  
Sent By jgomez Date 1999-11-02 Time 15:49 Rev Time 0.25
Received By jgomez Date 1999-11-02 Time 15:49 Sent To  
Notes
2001-01-08 00:00:00FIRE RATED CEILING ASSEMBLY UL-P522.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 1999-10-21 Cont ID  
Sent By jgomez Date 1999-10-21 Time 18:36 Rev Time 0.25
Received By jgomez Date 1999-10-21 Time 18:36 Sent To  
Notes
2001-01-08 00:00:00REVIEW OF REVISED UNIT B-2 BY MASTER
 BEDROOM CLOSET.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 1999-10-02 Cont ID  
Sent By jgomez Date 1999-10-02 Time 13:30 Rev Time 1.00
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00REVIEWED REVISIONS 10-2-99. JG

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 1999-08-14 Cont ID  
Sent By jgomez Date 1999-08-14 Time 14:39 Rev Time 2.00
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE 3 COPIES OF EACH UL FIRE RATED
 ASSEMBLY SPECIFIED.
 2-ATTIC ACCESS TO BE 22"X36" MIN. AS PER
 SEC. 2309.6 SBC 1994.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-04-28 Cont ID  
Sent By jgomez Date 1999-04-26 Time 16:12 Rev Time 0.25
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00SPRINKLER SYSTEM TO BE 13,NOT 13R

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-04-11 Cont ID  
Sent By jleahy Date 2000-04-11 Time 15:15 Rev Time 0.45
Received By jleahy Date 2000-04-11 Time 15:14 Sent To  
Notes
2001-01-08 00:00:00OUTLET WILL NOT FIT IN WALL WITH DOOR JL
  
 THIS REVISION #2 ON PLANS

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-04-28 Cont ID  
Sent By jgomez Date 1999-04-28 Time 12:18 Rev Time  
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED BY JAKE. SEE APPLICATION

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 1999-04-28 Cont ID  
Sent By jgomez Date 1999-04-28 Time 12:19 Rev Time  
Received By jgomez Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-04-28 Cont ID  
Sent By jgomez Date 1999-04-28 Time 12:31 Rev Time  
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO BY FIRE DEPT

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-04-05 Cont ID  
Sent By cthirben Date 2000-04-05 Time 09:14 Rev Time 1.00
Received By cthirben Date 2000-04-05 Time 09:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 1999-11-16 Cont ID  
Sent By jleech Date 1999-11-16 Time 08:02 Rev Time 1.00
Received By jleech Date 1999-11-16 Time 08:01 Sent To  
Notes
2001-01-08 00:00:00DENIED;
 BATHROOM EXHAUST VENT SHAFTS CANNOT BE
 OMITTED PER CHAPTER SIX OF THE 1994
 STANDERD MECHANICAL CODE.SECTIONS
 610.2 CEILING PENETRATION 610.4
 FLOOR PENETRATIONS AND 610.2 #3

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-04-28 Cont ID  
Sent By jgomez Date 1999-04-28 Time 12:32 Rev Time  
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED BY NANCY. SEE APPLICATION

Review Stop P PLUMBING
Rev No 4 Status F Date 1999-08-17 Cont ID  
Sent By tlarge Date 1999-08-17 Time 09:41 Rev Time 0.00
Received By tlarge Date 1999-08-17 Time 09:41 Sent To  
Notes
2001-01-08 00:00:00SEPARATE PERMIT REQ'D.FOR FOUNTAINS.SPC
 SEC.104.1.1
  
 PLANS REFER TO CIVIL DRWGS.FOR CONTIN-
 UATION OF FOUNTAIN DISCHARGE PIPING.
 SUBMIT CIVIL DRWGS.THAT CLEARLY SHOW
 PIPING.SPC 104.2.1.
  
 SUBMIT FOUNTAIN PLANS FOR REVIEW.SPC
 104.2.1.
  
 ***NOTE:PERMIT APPL.& PLANS SHALL
 REFLECT CORRECT BLDG.(EAST OR WEST.)

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-07-06 Cont ID  
Sent By tlarge Date 1999-07-06 Time 16:36 Rev Time 0.50
Received By tlarge Date 1999-07-06 Time 16:35 Sent To  
Notes
2001-01-08 00:00:00SUBMITTED REVISED SANITARY RISER DIGRAMS

Review Stop P PLUMBING
Rev No 2 Status N Date 1999-05-22 Cont ID  
Sent By pschmitz Date 1999-05-22 Time 12:51 Rev Time 0.75
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-04-23 Cont ID  
Sent By pschmitz Date 1999-04-23 Time 13:54 Rev Time 2.00
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-04-28 Cont ID  
Sent By jgomez Date 1999-04-28 Time 12:34 Rev Time  
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED BY GRACE. SEE APPLICATION