| Plan Review Stops For Permit 99030676 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-02-01 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-02-01 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-01 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************ PROVISO******************* | | | | | | 1)NOTE: PLEASE SHOW EXISTING SERVICE | | | SIZE. | | | | | | 2)NOTE: PLEASE CHECK HEATSTRIP ON AHU | | | HEAT STRIPS ARE USUALLY 5,71/2 AND 10KW | | | STRIPS?? SHOW TOTAL SQ.FT. FOR LOAD CALC | | | RE-DO LOAD CALCS. | | | | | | 3)NOTE: WP GFI RECEPT IN BACK OF | | | DWELLING. AS PER 210-52E | | | | | | NEED TO SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW AND APPROAL BEFORE ROUGH | | | ELECTRICAL INSPECTION.IF THERE ARE ANY | | | QUESTIONS PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
1999-12-03 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-12-02 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-12-03 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***********UNSAT*********************** | | | | | | 1)NOTE: NEED LOAD CALCULATIONS AS PER | | | 220-3-D-1 | | | 2)NOTE: NEED TO SHOW SIZE OF EXISTING | | | SERVICE TO INCLUDE SERVICE WIRE SIZE. | | | 3)NOTE: NEED TO SHOW NEW PANEL SCHEDULE | | | FOR ADDITION OF NEW CIRCUTS TO EXISTING | | | PANEL. DINING AREA REQ`S 20 AMP BRANCH | | | CIRCUTS AS PER CODE. | | | 4)NOTE: ALSO AS PER 210-52D BATH REC IS | | | TO ON IT`S OWN 20 AMP BRANCH CIRCUT. | | | 5)NOTE: PLEASE SHOW EXISTING LOCATION | | | OF REC AT REAR OF RESIDENCE AS REQ`D BY | | | 210-52 E IF NO REC EXIST THEN ONE NEEDS | | | TO BE ADDED TO REAR OF ADDITION. | | | 6)NOTE: NEED TO HAVE SMOKE DETECTORS | | | INSIDE AND OUTSIDE ALL NEW BEDROOMS | | | AS REQ`D BY NFPA-72 2-2.1.1.1 1993/1996 | | | EDDITION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW AND APPROVAL. IF THERE ARE | | | ANY QUESTIONS OR I CAN BE OF ANY ASST. | | | PLEASE CONTACT ME AT 659-8096 EXT8372 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2000-02-01 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-12-02 |
Time |
07:23 |
Rev Time |
0.33 |
| Received By |
fknapp |
Date |
1999-12-02 |
Time |
07:22 |
Sent To |
E |
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING HAS BEEN DELETED-FK |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2000-02-01 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-02-01 |
Time |
14:27 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-02-01 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2000-01-27 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-01-27 |
Time |
11:19 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-01-27 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ****************DENIED****************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COPIES OF PRODUCT | | | APPROVALS FOR NEW EXTERIOR WINDOW. | | | | | | 2)PROVIDE 2 CURRENT COPIES OF PRODUCT | | | APPROVALS FOR STORM PANELS COMPLETE | | | WITH INSTALLATION SCHEDULE AND KEY PLAN | | | WITH SPECIFIC ANCHORS TO BE USED. | | | | | | 3)PROVIDE ENERGY CALCULATIONS. | | | | | | 4)PROVIDE DETAIL OF FAMILY ROOM WALL AT | | | STORAGE ROOM. | | | | | | 5)BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO., THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECIEPT ATTACHED TO THE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-01-13 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-01-13 |
Time |
08:39 |
Rev Time |
3.00 |
| Received By |
fknapp |
Date |
2000-01-12 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ****************DENIED****************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COPIES OF PRODUCT | | | APPROVALS FOR: | | | NEW EXTERIOR DOORS AND WINDOWS | | | ROOF COVERING | | | MISSILE IMPACT RESISTANCE INFORMATION | | | | | | 2)PROVIDE ENERGY CALCULATIONS | | | | | | 3)PROVIDE BEAM HEIGHT ELEVATIONS | | | | | | 4)PROVIDE ROOF SHEATHING NAILING ZONES | | | COMPLYING WITH SBC FIG 2306.1 | | | | | | 5)PROVIDE WINDOW AND DOOR BUCK | | | CONNECTION DETAIL FOR WINDLOAD | | | RESISTANCE SBC 1606 | | | | | | 6)PROVIDE VIEW OF EXISTING BACK WALL TO | | | SHOW HOW ACCESS WILL BE OBTAIN AND ANY | | | DEMOLITION TO BE DONE. | | | | | | 7)RAFTERS SPECIFIED,#2-2 X 8'S WILL ONLY | | | SPAN 13'-9" PLEASE REVISE TO COMPLY. #2- | | | 2 X 10'S RAFTERS WILL SPAN 16'-5" | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUE,IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO., THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECIEPT ATTACHED TO THE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
1999-12-07 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
1999-12-07 |
Time |
10:24 |
Rev Time |
3.00 |
| Received By |
fknapp |
Date |
1999-12-07 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ****************DENIED****************** | | | | | | SBC104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COPIES OF PRODUCT | | | APPROVALS FOR: | | | NEW EXTERIOR DOORS AND WINDOWS | | | ROOF COVERING | | | MISSILE IMPACT RESISTANCE INFO | | | | | | 2)PROVIDE COMPLETE FLOOR FRAMING PLAN | | | | | | 3)PROVIDE ADDRESS AND PHONE# OF DESIGNER | | | | | | 4)PROVIDE ENERGY CALCULATIONS INCLUDING | | | MANUEL J | | | | | | 5)PROVIDE BEAM HEIGHT ELEVATIONS | | | | | | 6)PROVIDE COMPLETE DETAIL OF STAIRS TO | | | COMPLY WITH SBC 1006,1007,1015 | | | | | | 7)PROVIDE INTERIOR WALL SECTION DETAIL | | | | | | 8)PROVIDE TRUSS PLAN LAYOUT WITH DESIGN | | | INFORMATION SBC 1606 OR ASCE-7-95 | | | | | | 9)PROVIDE ROOF SHEATHING NAILING ZONES | | | COMPLYING WITH SBC FIG.2306.1 | | | | | | 10)PROVIDE WINDOW AND DOOR BUCK | | | CONNECTION DETAIL FOR WINDLOAD | | | RESISTANCE SBC 1606 | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED,IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO., THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECIEPT ATTACHED TO THE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2000-02-01 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-02-01 |
Time |
15:07 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
1999-04-19 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-03-19 |
Time |
13:58 |
Rev Time |
|
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|