Plan Review Details - Permit 99021083
Plan Review Stops For Permit 99021083
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-04-15 Cont ID  
Sent By jgomez Date 1999-04-15 Time 17:00 Rev Time  
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED BY JAKE. SEE APPLICATION

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-04-15 Cont ID  
Sent By jgomez Date 1999-04-15 Time 17:01 Rev Time  
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED BY JLEECH. SEE APPLICATION

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-04-15 Cont ID  
Sent By jgomez Date 1999-04-15 Time 17:02 Rev Time  
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED BY JLEECH. SEE APPLICATION

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 1999-10-27 Cont ID  
Sent By jgomez Date 1999-10-27 Time 17:15 Rev Time 0.50
Received By jgomez Date 1999-10-27 Time 17:15 Sent To  
Notes
2001-01-08 00:00:00 
 STORM PANELS APPROVED WITH PROVISO:
 1-ANCHOR SPACING TO BE ACCORDING TO THE
 ANCHOR SCHEDULE TABLE ON PAGE 6 OF 7
 OF STORM PANEL DRAWINGS (#98-225P)
 CONSIDERING THE DESIGN PRESSURES AND
 STORM PANELS SPANS.
 2-MINIMUM PANEL LENGTH FOR DIRECT MOUNT
 STORM PANEL IS 44" AS PER TABLE 3 OF
 APPROVED STORM PANELS DRAWINGS (DWG #
 98-225P).

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 1999-10-01 Cont ID  
Sent By jgomez Date 1999-10-01 Time 15:27 Rev Time 0.50
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00CHECKLIST FOR STORM PANELS:
 1-ANCHOR SCHEDULE SPECIFIED IS FOR
 A CONCRETE STRUCTURE. HOUSE IS BUILT
 OUT OF HOLLOW CONCRETE BLOCK.
 REVISE ANCHOR SCHEDULE ACCORDINGLY.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 1999-09-17 Cont ID  
Sent By jgomez Date 1999-09-17 Time 17:08 Rev Time 0.50
Received By jgomez Date 1999-09-17 Time 17:08 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 STORM PANELS:
 1-HIGHLIGHT SPECIFIC MOUNTING CONDITIONS
 USED ON THIS PROJECT.
 2-HIGHLIGHT AND SPECIFY ANCHOR AND
 SPACING TO BE USED.
 NOTE THAT ANCHOR SPACING VARIES
 ACCORDING TO THE EDGE DISTANCE, SPAN OF
 PANEL AND DISTANCE FROM GLASS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 1999-09-02 Cont ID  
Sent By jgomez Date 1999-09-02 Time 17:36 Rev Time 0.25
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00PRODUCT APPROVAL FOR EXTERIOR DOORS WAS
 APPROVED.JG.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-04-15 Cont ID  
Sent By jgomez Date 1999-04-15 Time 17:39 Rev Time  
Received By jgomez Date   Time   Sent To O
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO

Review Stop Z ZONING
Rev No 1 Status P Date 1999-04-15 Cont ID  
Sent By gjoyce Date 1999-04-15 Time 11:12 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***