| Plan Review Stops For Permit 99021077 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
1999-09-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
1999-06-28 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-06-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
1999-06-01 |
Time |
12:27 |
Rev Time |
|
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2000-08-14 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-08-14 |
Time |
13:58 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PASSED WITH PROVISOS | | | 1. PROVIDE PROPERTY INFORMATION ON | | | 8 1/2 X 11 SHEET. | | | INCLUDE JOB TITLE | | | PROPERTY ADDRESS | | | PROPERTY CONTROL NUMBER | | | INCLUDE ALL PERVIOUS INFORMATION | | | AND IMPERVIOUS INFORMATION | | | PLEASE STATE QUANTITIES IN SQ.FT. AND | | | IN ACRES. | | | THESE QUANTITIES WILL PROVIDE THE | | | INFORMATION WHICH WILL CALCULATE THE | | | STORM CHARGES FOR THIS SITE. | | | PLEASE SUBMITT INFORMATION TO | | | MANNY GONZALEZ, PUBLIC UTILITIES | | | 1000 45TH STREET SUITE 15 | | | WEST PALM BEACH, FL 33407 | | | (561)659-8040 | | | FAX (561) 659-8039 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
1999-09-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
1999-06-28 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
1999-06-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
1999-05-26 |
Time |
12:28 |
Rev Time |
|
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
1999-07-19 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-07-19 |
Time |
14:26 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
1999-07-19 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-07-19 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-06-02 |
Time |
13:31 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
1999-07-19 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************DENIED******************* | | | 1) MECHANICAL PLANS SHOW INCOMPLETE DE- | | | TAILS ON DUCT SIZES AND MATERIAL. SUBMIT | | | DETAILS ON DUCTS, SIZES,AND EQUIPMENT | | | 2) PROVIDE OUTSIDE AIR CALCULATIONS PER | | | ASHRAE 62-89 | | | 3) BOTH BATHROOMS IN WORK AREA REQUIRE | | | EXHAUST FANS PER 1994 SMC 503.3 | | | 4) PROVIDE INFORMATION ON EXHAUST FANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-08-20 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-20 |
Time |
10:39 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-08-20 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************PROVISO***************** | | | SUBMIT SIGNED,DATED AND SEALED SANITARY | | | AND WATER RISER DIAGRAMS PRIOR TO PLBG. | | | INSPECTION.COUNTYWIDE AMENDMENTS TO SPC | | | SEC.104.2.1.,104.2.3. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
1999-08-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-08-19 |
Time |
14:01 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO:SHT.P-4.1 WTR HTR TO BE READLY | | | ACCESSIBLE SPC 94 SEC 501.7 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
1999-08-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-07-14 |
Time |
15:07 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
1999-08-04 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED | | | (1) SHT 3.1 CUT SHT ON BREAK RM DF | | | BUBBLER.FACBC 4.15 | | | (2) SHT 3.1 BREAK RM SINK HEIGHT TO BE | | | 34". FACBC 4.24.2 | | | (3) SHT 3.1 SHOW LOCATION OF BREAK RM | | | SINK ON DWV ISOMETRIC. | | | (4) SHT 3.1 SHOW WATER RISER ISOMETRIC | | | WITH PIPE SIZES. | | | END OF COMMENTS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-08-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-06-12 |
Time |
09:36 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED | | | (1) SHT 3.1 WATER HEATER ABOVE CEILING, | | | SHOWER TO BE READLY ACCESSIBLE SEC 501.7 | | | SHOW A DETAILOF THE STATIONARY LADDER | | | FOR THE COMPLIANCE OF THIS SECTION. | | | (2) SHT 4.1 SHOW LOCATION OF BACK FLOW | | | PREVENTER ON WATER SERVICE. | | | (3) SHT LS-2 PROVIDE IRRIGATION PLANS AS | | | PER NOTE FOR IRRIGATION. | | | END OF COMMENTS |
|
|