Plan Review Details - Permit 99011086
Plan Review Stops For Permit 99011086
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 1999-08-10 Cont ID  
Sent By hpiskura Date 1999-08-10 Time 09:57 Rev Time 2.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00REV DATED 6/30/99

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-03-11 Cont ID  
Sent By nleiva Date 1999-03-11 Time 10:31 Rev Time 8.00
Received By sgraham Date 1999-02-25 Time 09:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 1999-11-01 Cont ID  
Sent By jleahy Date 1999-11-01 Time 12:00 Rev Time 0.45
Received By jleahy Date 1999-11-01 Time 12:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-03-01 Cont ID  
Sent By hpiskura Date 1999-02-25 Time 09:43 Rev Time  
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 1999-02-25 Cont ID  
Sent By hpiskura Date 1999-02-25 Time 09:44 Rev Time  
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00APP ON MIT 98008067

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-01-06 Cont ID  
Sent By hpiskura Date 1999-02-25 Time 09:48 Rev Time  
Received By bprusiec Date   Time   Sent To  
Notes
2001-01-08 00:00:00FIRE ALARM SHALL BE CLASS "A". PROVIDE N
 AME OF MONITORING COMPANY AND CUT SHEETS
 ON DEVICES. PROVIDE DETAIL SHOP DRAWINGS
 AND CUT SHEETS FOR FIRE SPRINKLER SYST.
 PROVIDE DETAILS CONCERNING FIRE PUMP AND
 EMER. GENERATOR AS NEEDED.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 1999-08-30 Cont ID  
Sent By ndenmark Date 1999-08-30 Time 13:29 Rev Time 0.25
Received By ndenmark Date 1999-08-30 Time 13:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 1999-07-26 Cont ID  
Sent By ndenmark Date 1999-07-26 Time 13:33 Rev Time 0.33
Received By ndenmark Date 1999-07-26 Time 13:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 1999-05-24 Cont ID  
Sent By ndenmark Date 1999-05-24 Time 10:55 Rev Time 0.25
Received By ndenmark Date 1999-05-24 Time 10:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 1999-05-24 Cont ID  
Sent By ndenmark Date 1999-04-19 Time 14:47 Rev Time 1.00
Received By ndenmark Date 1999-04-19 Time 14:47 Sent To  
Notes
2001-01-08 00:00:00**************DENIED*******************
 1) FIRE DAMPER REQUIRED AT 18X6 RAG ON
 AC105 PER 1994 SMC 610.1.2
 2) PROVIDE OUTSIDE AIR CALCULATIONS PER
 ASHRAE 62-89
 3) PROVIDE AIR BALANCE SCHEDULE PER 1994
 SMC 501.2 FOR PRESSURE EQUILIZATION
 4)PROVIDE EER INFORMATION ON MECHANICAL
 EQUIPMENT PER FLORIDA ENERGY EFFICIENCY
 CODE FOR BUILDING CONSTRUCTION 1997 EDIT

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-01-04 Cont ID  
Sent By hpiskura Date 1999-02-25 Time 09:48 Rev Time  
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 1999-11-12 Cont ID  
Sent By tlarge Date 1999-11-12 Time 17:33 Rev Time 0.33
Received By tlarge Date 1999-11-12 Time 17:33 Sent To  
Notes
2001-01-08 00:00:00COPY OF RECEIPT FOR WATER USE PERMIT ON
 FILE.COPY OF ACTUAL PERMIT IS REQD.PRIOR
 TO FINAL IRRIG.INSPECTION.

Review Stop P PLUMBING
Rev No 4 Status P Date 1999-11-08 Cont ID  
Sent By tlarge Date 1999-11-08 Time 11:09 Rev Time 0.50
Received By tlarge Date 1999-11-08 Time 11:09 Sent To  
Notes
2001-01-08 00:00:00REVISION TO WATER HEATER INFORMATION .

Review Stop P PLUMBING
Rev No 3 Status F Date 1999-11-04 Cont ID  
Sent By tlarge Date 1999-11-04 Time 18:40 Rev Time 0.30
Received By tlarge Date 1999-11-04 Time 18:40 Sent To  
Notes
2001-01-08 00:00:00COPY OF MODIFIED WATER USE PERMIT FROM
 SO.FLA.WATER MANAGEMENT REQD.PER FLA.
 STATUTE 373.219.

Review Stop P PLUMBING
Rev No 2 Status F Date 1999-07-17 Cont ID  
Sent By tlarge Date 1999-07-17 Time 12:17 Rev Time 3.50
Received By tlarge Date   Time   Sent To  
Notes
2001-01-08 00:00:00 
 SUBMIT REVISED STORM DRAINAGE ISOMETRIC
 THAT REFLECTS ALL CHANGES MADE TO THE
 SYSTEM. INDICATE SLOPE OF PIPE ON PLANS.
 PC 104.2.1.
 SUBMIT REVISED WATER AND SANITARY ISO.TO
 REFLECTALL CHANGES TO THE SYSTEM.
 (ADDED SINKS,WATER HEATERS,ETC.)
 SPC 104.2.1.
  
 SHT.P701-CLEARLY SHOW ORIGINATION PT.OF
 ADDED 3/4"WATER AND 3"SAN.LINE ON FIRST
 FLOOR PLUMBING PLAN.(WHAT IS DRAINING
 INTO THIS LINE?) SHOW ON APPROPRIATE
 RISER DIAGRAM. SPC 104.2.1.
  
 LUNCH ROOM SINK SHALL COMPLY W/F.A.C.B.C
 SEC.4.24.1 - 4.24.7.

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-01-20 Cont ID  
Sent By hpiskura Date 1999-02-25 Time 09:49 Rev Time  
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-03-11 Cont ID  
Sent By nleiva Date 1999-03-11 Time 10:31 Rev Time  
Received By nleiva Date   Time   Sent To  
Notes
***NONE***