Plan Review Details - Permit 98121020
| Plan Review Stops For Permit 98121020 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
1999-02-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-02-02 |
Time |
11:28 |
Rev Time |
7.00 |
| Received By |
hpiskura |
Date |
1999-01-29 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-01-21 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-02-02 |
Time |
11:28 |
Rev Time |
|
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
1999-01-07 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-02-02 |
Time |
11:29 |
Rev Time |
|
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
1999-03-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-01-15 |
Time |
15:12 |
Rev Time |
1.50 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SEE PLUMBING NOTES. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-01-22 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-01-22 |
Time |
10:53 |
Rev Time |
1.50 |
| Received By |
ndenmark |
Date |
1999-01-22 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO:SEPARATE PERMITS REQUIRED FOR | | | HOOD AND SUPPRESSION SYSTEM FOR HOOD | | | 2) EXISTING DUCTS TO BE REUSED TO BE INS | | | PECTED FOR CLEANLINESS AND CLEANED AND | | | SANITIZED BY LICENSED MECH. CONTRACTOR | | | 3) CEILING DIFFUSERS IN RATED CEILING TO | | | BE RADIANT TYPE-RATED DIFFUSERS,SEE A-8 | | | DETAIL 4 | | | 4) MACHINERY ROOMS ON ROOF TO BE VENTI- | | | LATED AND PROTECTED PER 1994 SMC CH.11, | | | INCLUDING LEVEL 1 MACHINE ROOM 1105 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-03-04 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-01-15 |
Time |
14:36 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
1999-01-15 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PLAN REVIEW 94 STD PLBG CODE | | | CONTACT PAUL SCHMITZ 561-659-8096 X8233 | | | | | | (1) SHT.PM-6 GENERAL 1.1.1.8, 3.4.1.1 | | | HUB DRAINS PROHIBITED,USE FLOOR SINKS. | | | (2) SHT P-3 GREASE TRAPS: CONTACT W. | | | PALM BCH REG. SEWER TREATMENT PLANT FOR | | | GREASE TRAP SIZE 561-686-6324 | | | (3) SHT. P-4 GAS PIPING: SHOW BTU'S OF | | | EACH APPLIANCE, TOT. BTU'S,TOT. DEVE- | | | LOPED LENTH, ISOMETRIC DRWG. | | | (4) SHT P-5 SAFE WASTEPROHIBITED,USE | | | HORIZONTAL WASTE & VENT,SPC SEC 921. | | | (5) A/C CONDENSATE: TO STORM DRAIN, DRY | | | WELL, OR PLANTER,NOT TO SANITARY SEWER. | | | (6) DISH WASHER TO SANITARY SEWER. | | | (7) SHT P-7 DETAIL 4 SANITIZER SYSTEM: | | | WATTS #7 BFP NOT APPROVED, USE WATTS | | | 36N ANTI SYPHON DEVICE. | | | (8) DETAIL 12 FOOD PREPARATION SINK: EA. | | | COMPARTMENT WASTE TO HAVE A SEPERATE | | | WASTE TO FLOOR SINK. | | | (9) DISH WASHERS TO BY PASS GREASE TRAP. | | | END OF COMMENTS | | | PERMIT ISSUED WIHH PROVISO SEE LIST | | | 03-04-99PES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1998-12-29 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1998-12-29 |
Time |
13:37 |
Rev Time |
|
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy