| Plan Review Stops For Permit 98120860 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
1999-09-10 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-09-10 |
Time |
15:21 |
Rev Time |
2.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
1999-10-05 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-01-12 |
Time |
16:37 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
1999-01-12 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-05-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-16 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-16 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** PROVISO *************** | | | | | | NOTES ON PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-10-05 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-01-12 |
Time |
16:37 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2001-05-22 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-05-22 |
Time |
08:29 |
Rev Time |
3.00 |
| Received By |
mamini |
Date |
2001-05-22 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2001-05-22 00:00:00 | PASSED: | | | 1. RESPONSES TO PREVIOUS REVIEW COMMENTS | | | DATED 4-24-01 SATISFACTORY.PLANS HAVE | | | BEEN REVISED PER REVIEW COMMENTS AND | | | CALCULATIONS PROVIDED. | | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | | EXT. 8492 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2001-04-20 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-04-20 |
Time |
11:26 |
Rev Time |
4.00 |
| Received By |
mamini |
Date |
2001-04-20 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2001-04-20 00:00:00 | FAILED: | | | 1. PLEASE PROVIDE ITEMS AS INDICATED ON | | | ATTACHED SHEET FOR STORM WATER | | | CONSTRUCTIONS TO, JOSE DEL RIO, STORM | | | WATER ENGINEER, 1000 45TH STREET WEST | | | PALM BEACH, FL 33407 561-659-8040. | | | 2. PLEASE STATE IF GARBAGE IS TO BE | | | PICKED UP BY THE CITY OR IF IT IS | | | PRIVATE PICKUP.CITY PICKUP THEN THE | | | FOLLOWING REQUIREMENTS MUST BE MET.SEE | | | ATTACHED | | | 3. THE "APPLICATION FOR CONSTRUCTION | | | WITHIN PUBLIC R.O.W" MUST BE SUBMITTED | | | TO CITY ENGINEER, RICHARD PITTMAN | | | 100045TH STREET WEST PALM BEACH, FL | | | 33407 561-569-8040. SEE ATTACHED | | | 4. A SEPARATE PERMIT FOR UNDERGROUND | | | UTILITIES CONSTRUCTION MAY BE REQUIRED. | | | PLEASE CONTACT, DEAN RUNNELS LIC./PER. | | | SUPERVISOR, 200 2ND STREET WEST PALM | | | BEACH, FL 33407561- 659-8040 EXT. 8496 | | | 5. PLEASE CONTACT RODNEY COMPO UTILITIES | | | TECHNICIAN ( INDUSTRIAL PRETRETMENT ) | | | FOR INSTALLATION, INSPECTIONS ON GREASE/ | | | WATER SEPARATOR561-837- 4051 EXT. 4074 | | | 6. PLEASE PROVIDE DETAIL/ SIZE FOR | | | JUNCTION BOX AS SHOWN ON SHEET C-2 | | | 7. PLEASE SHOW POINT OF CONFLICTS, WHERE | | | WATER CROSSING SANITARY AND STORM WATER | | | LINES AND INDICATE INVERTS/CROWNS ELEV. | | | 8. PLEASE COORDINATE WITH PUBLIC | | | UTILITIES ENGINEERING SERVICES FOR | | | CONNECTING TO INLET.PROVIDE TWO SETS | | | OF PLANS FOR THIER APPROVAL AND ACTUAL | | | SERVICE CONNECTIONS. | | | 9. PLEASE SHOW HORIZANTAL CLEARANCES | | | BETWEEN THE SERVICE LINES. | | | | | | IF ANY QUESTIONS PLEASE CONTACT 561-569- | | | 8096 EXT. 8492 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
1998-12-28 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-01-12 |
Time |
16:38 |
Rev Time |
|
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
1999-12-16 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-10-21 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
1999-12-14 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ORIGINAL MECH DRAWINGS ENGINEER SEALED | | | REVISED SET NOT SEALED CANNOT ACCEPT | | | CONTRACTOR CALLED TO SUBMIT ENGINEER | | | APPROVED AND SEAL DRAWING FOR REVISION | | | SHOWING AREAS CHANGED INDICATED BY CLOUD | | | OR TRIANGLE | | | CONTRACTOR WILL USE APPROVED DRAWINGS | | | THIS REVISION IS VOID. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
1999-10-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-10-04 |
Time |
15:28 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
1999-10-04 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | FAN SHUT DOWN TO BE TIED TO HORN AND | | | STROBE FOR NOTIFICATION PER NFPA 4-4.4.3 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
1999-10-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-09-01 |
Time |
12:27 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
1999-09-01 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PRIOR PLAN REVIEW COMMENTS NOT CORRECTED | | | FROM 12/22/98 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-10-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-01-04 |
Time |
11:27 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
1999-01-04 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NEED OUTSIDE AIR CALCULATIONS PER | | | ASHRAE 62-89 | | | 2) NEED AIR BALANCE SCHEDULE PER 1994 | | | SMC 501.2 | | | 3) FAN SHUT DOWN BY DUCT SMOKE DETECTOR | | | REQUIRED PER 1994 SMC 406.1 | | | 3A) NOTIFICATION TO BE PER 1996 NFPA 90A | | | 4-4.4.2 OR 4-4.4.3 STOBE AND HORN | | | 4) SECOND FLOOR DUCT TO BE INSULATED W/ | | | R-6 PER FLORIDA ENERGY EFFICIENCY CODE | | | 1997, UNLESS ROOF IS INSULATED TO R-16 | | | 5) ROOF PLAN DOES NOT SHOW EXHAUST FAN | | | TERMINATION LOCATION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-06-27 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-06-27 |
Time |
09:00 |
Rev Time |
5.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-27 00:00:00 | PLUMBING REVISION, DELETE (1) GREASE | | | TRAP.OK PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-04-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-04-18 |
Time |
18:06 |
Rev Time |
2.50 |
| Received By |
jleech |
Date |
2001-04-18 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2001-04-18 00:00:00 | SITE PLANS DENIED; | | | | | | NOT ENOUGH INFORMATION; | | | | | | 1.WHAT SIZE ARE GREASE TRAPS? | | | | | | 2.WHY IS THERE 3 GREASE TRAPS? | | | | | | 3.GREASE TRAPS SHALL BE REVIEW AND | | | APPROVED BY THE UTILITY DEPARTMENT. | | | CALL RODNEY COMPO AT 837-4074. | | | | | | 4.TWO WAY CLEANOUTS ARE REQUIRED BETWEEN | | | EACH TANK AND AT THE FRONT OF THE | | | FIRSTTANK AND AFTER THE LAST TANK. | | | | | | 5.WHY IS SEWER AND WATER TIDED INTO TWO | | | BUILDINGS? EACH BUILDING SHOULD HAVE | | | ITS OWN HOOKUP. | | | | | | 6.NEED CAULKULATIONS FOR STORM DRAINAGE | | | PIPING.PLEASE SHOW SQUIRE FOOTAGE TO | | | BE DRAINED. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8377 OR 8369 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
1999-08-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-08-19 |
Time |
10:25 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: SHT.P-2 SECONDARY DRAINAGE | | | SYSTEM REQUIRED, ( SCUPPERS) | | | SEE NOTES ON ISOMETRIC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-08-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
1999-01-06 |
Time |
15:23 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | PLUMBING PLAN REVIEW 94 STD.PLBG. CODE | | | UNSAT CONTACT PAUL SCHMITZ 561-659-8096 | | | X 8233 | | | (1) SHT. P-1 NO HORIZONTAL DRY VENTS. | | | (2) SHT. P-1 CONTACT REGIONAL SEWER | | | TREATMENT PLANT, 561-688-6324 | | | (3) SHT P-3 EQUIPMENT SCHEDULE INCOMPLET | | | SHOOW ALL EQUIPMENT WITH DRAINS | | | INCLUDING ICEBINS. | | | (4) SHT P-4 SAFE WASTE PROHIBITED. | | | (5) SHT P-4ALL INDIRECT WASTE TO FLOOR | | | SINKS, NO HUB DRAINS. | | | (6) SHT P-4 TOTAL DEVELOPED LGTH GAS. | | | (7) SHT P-4 EMERGENCY GAS VALVE BELOW | | | CEILING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-09-10 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-09-10 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|