Plan Review Details - Permit 98100755
Plan Review Stops For Permit 98100755
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-07-12 Cont ID  
Sent By dpalmer Date 1999-07-12 Time 18:48 Rev Time 0.00
Received By dpalmer Date 1999-07-12 Time 18:48 Sent To  
Notes
2001-01-08 00:00:00****************************************
  
 NOTE:ASBUILTS ARE REQ`D BEFORE FINAL
 INSPECTION IS CALLED IN.
 NOTE: SMOKE DETECTORS ARE REQ`D INSIDE
 AND OUTSIDE BEDROOMS AS PER NFPA-72.
 NOTE:MISSING OUTLETS AS PER 210-52E
 REQ`D FRONT AND BACK OF RESIDENCE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 1999-09-09 Cont ID  
Sent By ndenmark Date 1999-09-09 Time 15:58 Rev Time 1.00
Received By ndenmark Date 1999-09-09 Time 15:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-09-09 Cont ID  
Sent By ndenmark Date 1999-07-07 Time 09:07 Rev Time 0.50
Received By ndenmark Date 1999-07-07 Time 09:07 Sent To  
Notes
2001-01-08 00:00:00**************DENIED********************
  
 THESE COMMENTS APPLY TO ALL MODEL TYPES
  
 1) OVERFLOW PROTECTION REQUIRED ON ALL
 AIR HANDLERS
 2) DRYER VENTS EXCEEDING 25' LENGTH ALL-
 OWED PER CODE INCL. 5' DEDUCTION FOR EA.
 90 AND 2.5' DEDUCTION FOR EA. 45 DEGREE
 BEND TO PROVIDE MANUFACTURES SPECS WITH
 ALLOWED LENGTHS AND EQUIPMENT TO BE INS-
 TALLED AT FINAL INSPECTION
 3) CONDENSER ACCESS TO COMPLY WITH SMC
 AND NEC MIN. 36 INCHES FOR ELEC ACCESS
 AND 24 INCHES FOR MECH
 4) ANY DIFFUSERS PENETRATING RATED CEIL-
 INGS TO HAVE RATED FIRE DAMPERS INSTALL-
 ED

Review Stop P PLUMBING
Rev No 4 Status P Date 1999-10-27 Cont ID  
Sent By tlarge Date 1999-10-27 Time 11:58 Rev Time 0.50
Received By tlarge Date 1999-10-27 Time 11:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 1999-10-23 Cont ID  
Sent By tlarge Date 1999-10-23 Time 11:30 Rev Time 3.00
Received By tlarge Date 1999-10-23 Time 11:30 Sent To  
Notes
2001-01-08 00:00:00THESE COMMENTS APPLY TO ALL MODEL TYPES
  
 CLEANOUTS SHALL BE INSTALLED IN THE
 HORIZONTAL DRAINAGE PIPING PER SPC SEC.
 710.2.4.(1)(2).
  
 RISER NUMBERS ON SHT P-7 DON'T CORRELATE
 W/SHT.P-14.(SEE FLOOR PLAN D1.1.)SPC
 SEC.104.2.1.
  
 LOCATION OF FIXTURES ON RISERS S-1A,6,6A
 DOESN'T CORRELATE W/FLOOR PLAN ON SHT.P7
  
 SHT.P-20-RISERS S10 AND S9 ARE MIS-
 LABELED.(SEE SHT.P-7.WATER CLOSETS
 SHOULD BE LABELED AS S9,TUBS AND LAVS.AS
 S10.)
  
 REVISE FIXTURE UNIT LOAD FOR W/M RISERS.
 COMPLY W/TABLE 713.1.
  
 SIZE OF VENT STACKS FOR RISERS # 1,2,6,7
 9,11,13,14.SHALL COMPLY W/SPC SEC.911.3.
  
 PLANS SHALL BE SIGNED AND SEALED PER
 SBC SEC.104.2.2. AND SPC SEC.104.2.3
  
 MIN.SIZE OF DRAIN PAN RISER SHALL BE
 1 1/4" PER COUNTYWIDE AMENDMENTS TO SPC
 SEC.507.8.3.(MIN.SIZE PAN DRAIN SHALL BE
 1" PER SPC SEC.507.8.2.)
  
 SUBMIT DETAILS FOR WOOD BLOCKING FOR
 FUTURE HANDICAP GRAB BAR INSTALLATION
 PER FEDERAL FAIR HOUSING ACT.
 AND 24 CFR 100.205.
  
 SHOW WIDTH OF SHOWERS IN ALL UNITS.
 COMPLY W/COUNTYWIDE AMENDMENTS TO SPC
 SEC.409.8.2.1.
  
 NOTE:CALL TIMOTHY LARGE
 AT (561)659-8096,EXT.8377 TO ARRANGE AN
 APPOINTMENT TO REVIEW THESE COMMENTS.

Review Stop P PLUMBING
Rev No 2 Status F Date 1999-07-14 Cont ID  
Sent By tlarge Date 1999-07-14 Time 09:32 Rev Time 7.00
Received By tlarge Date 1999-07-15 Time 09:32 Sent To  
Notes
2001-01-08 00:00:00THESE COMMENTS APPLY TO ALL MODEL TYPES.
  
 SUBMIT SANITARY AND WATER ISOMETRICS FOR
 CAR WASH AND TRASH COMPACTOR AREAS PER
 SPC SEC.104.2.1.(AN APPROVED INTERCEPTOR
 SHALL BE INSTALLED PER SPC SEC.1004.5,
 1004.6.
  
 CLEANOUTS SHALL BE INSTALLED IN THE
 HORIZONTAL PIPING PER SPC.SEC-710.2.4.
 (1)(2).
  
 THE LABELING OF THE SANITARY RISERS ON
 SHEETS P-1,P-13,P-14,P-15 DON'T
 CORRELATE W/EACH OTHER. SPC SEC.104.2.1.
  
 INDICATE SLOPE OF PIPE ON PLANS.COMPLY
 W/SPC TABLE 714.1,714.2.
  
 LOCATION OF FIXTURES ON SANITARY RISERS
 SHALL MATCH THE ARCH.FLOOR PLANS.SPC
 SEC.104.2.1.
  
 SHT.P-20-SIZE OF PAN DRAIN RISER SHALL
 COMPLY W/COUNTYWIDE AMENDMENTS TO SPC
 SEC.507.8.3.
  
 RELIEF VALVE DRAIN AND PAN DRAIN SHALL
 NOT USE COMMON RISERS PER SPC SEC.
 507.8.4.
  
 FIXTURE UNIT LOAD FOR SANITARY RISERS
 SHALL COMPLY W/SPC TABLE 713.1.(CHECK
 W/M STACKS.)
  
 SIZE OF VENT STACKS FOR RISERS #1,2,6,7,
 9,11,13,14 SHALL COMPLY W/SPC SEC.911.1,
 911.3, AND TABLE 911.3.
  
 INDICATE TYPE OF OCCUPANCY OF BUILDING
 ON PLANS.SEE STD.BLDG.CODE AND PLBG.CODE
 SECS.104.2.3,AND 322.2 FOR REQ'S.FOR
 SIGNED AND SEALED DRAWINGS.

Review Stop P PLUMBING
Rev No 1 Status P Date 1998-10-28 Cont ID  
Sent By pschmitz Date 1998-10-28 Time 10:58 Rev Time 0.50
Received By pschmitz Date 1998-10-28 Time 10:58 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-10-28 Cont ID  
Sent By gjoyce Date 1998-10-17 Time 09:18 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00BLDG REV:L MAR

Review Stop Z ZONING
Rev No 1 Status P Date 1998-10-17 Cont ID  
Sent By gjoyce Date 1998-10-17 Time 09:18 Rev Time  
Received By gjoyce Date   Time   Sent To R
Notes
***NONE***