Plan Review Details - Permit 98100397
Plan Review Stops For Permit 98100397
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2000-02-29 Cont ID  
Sent By tlarge Date 2000-02-29 Time 14:32 Rev Time 99.00
Received By tlarge Date 2000-02-29 Time 10:07 Sent To  
Notes
2001-01-08 00:00:00PLANS APPROVED BY H.PISKURA.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2000-02-29 Cont ID  
Sent By hpiskura Date 1999-11-01 Time 09:11 Rev Time 2.00
Received By tlarge Date   Time   Sent To  
Notes
2001-01-08 00:00:004TH CHECKLIST

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2000-02-29 Cont ID  
Sent By hpiskura Date 1999-08-24 Time 08:16 Rev Time 1.50
Received By tlarge Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE RECEIPT FOR ADDED VALUE PAID

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1998-12-10 Cont ID  
Sent By jleahy Date 1998-12-10 Time 14:42 Rev Time 1.00
Received By jleahy Date 1998-12-10 Time 14:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-12-20 Cont ID  
Sent By rturnque Date 1999-12-20 Time 09:47 Rev Time 0.25
Received By rturnque Date   Time   Sent To  
Notes
2001-01-08 00:00:001. PROVIDE CLASS "A" OR ADDRESSABLE FIRE
 ALARM SYSTEM.
 2. PROVIDE PERMIT AND SHOP DRAWINGS FOR
 FIRE SPRINKLER SYSTEM.
 3. PROVIDE PANICK HARDWARE FOR ALL EXIT
 DOORS.
 4. PROVIDE PERMIT AND SHOP DRAWINGS FOR
 HOOD AND EXTINGUISHING SYSTEMS.
 5. BAR STOOLS SHALL BE SPACED 12 INCHES
 APART.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-09-01 Cont ID  
Sent By ndenmark Date 1999-09-01 Time 11:43 Rev Time 0.33
Received By ndenmark Date 1999-09-01 Time 11:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-02-29 Cont ID  
Sent By tlarge Date 2000-02-29 Time 14:29 Rev Time 1.25
Received By tlarge Date 2000-02-29 Time 14:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date 2000-02-29 Cont ID  
Sent By tlarge Date 1999-12-04 Time 10:02 Rev Time 1.50
Received By tlarge Date 1999-12-04 Time 10:01 Sent To  
Notes
2001-01-08 00:00:00CLEARLY SHOW OCCUPANT LOAD OF STRUCTURE
 PER SPC TABLE 407 TO ENSURE COMPLIANCE
 FOR REQD.TYPES AND AMOUNT OF PLBG.
 FIXTURES.
  
 TOILET STALLS SHALL COMPLY W/FACBC SEC.
 4.17.3.SEE EXCEPTION:NEW CONSTRUCTION.
 SHOW CLEAR SPACE OF 60"DIAMETER FOR
 WHEELCHAIR TURNING SPACE IN TOILET STALL
 AND TOILET ROOMS PER FACBC SEC.4.2.3.
  
 WET VENTS SHALL RECEIVE DISCHARGE FROM
 FIXTURE DRAINS ONLY.(WATER CLOSETS ON
 1ST.FLR CANNOT BE VENTED BY DRAIN TO 2ND
 FLR.)
  
 WATER HEATER SHALL BE READILY ACCESSIBLE
 A PERMANENT LADDER AND PLATFORM SHALL BE
 PROVIDED OR RELOCATE HTR. TO FLOOR.
 SPC 501.7
  
 SAFE WASTES NOT PERMITTED.INDIRECT WASTE
 SHALL DISCHARGE INTO TOP OF FLOOR SINK.
 PER SPC 804.1.
  
 DOOR ON HANDICAP STALL CANNOT SWING INTO
 CLEAR FLOOR SPACE FOR FIXTURES PER FACBC
 SEC.4.22.2.(SEE WOMEN'S R.R.)

Review Stop P PLUMBING
Rev No 2 Status N Date 2000-02-29 Cont ID  
Sent By tlarge Date 1999-11-04 Time 14:14 Rev Time 3.75
Received By tlarge Date 1999-11-04 Time 14:14 Sent To  
Notes
2001-01-08 00:00:00CLEARLY SHOW OCCUPANT LOAD OF STRUCTURE
 TO ENSURE COMPLIANCE W/TABLE 407 OF SPC
 FOR PLBG.FIXTURE REQS.
  
 TOILET STALLS SHALL COMPLY W/FACBC SEC.
 4.17.3.SEE EXCEPTION:NEW CONSTRUCTION.
 TOILET ROOMS SHALL COMPLY W/FACBC SEC.
 4.16.2.SHOW CLEAR SPACE OF 60"DIAMETER
 FOR WHEELCHAIR TURNING SPACE.
  
 H.C URINAL SHALL BE 17" A.F.F. ONE
 URINAL ON 1ST.FLR.SHALL COMPLY W/FACBC
 AND THE URINAL ON 2ND.FLR.SHALL COMPLY.
  
 WASTES FROM PREP OR RINSE SINKS SHALL BE
 INDIRECTLY WASTED TO FLOOR SINK(NO FLOOR
 DRAINS) PER SPC SEC.804.1.
  
 GREASE TRAP SHALL BE A MIN.OF 750 GALS.
 PER RULE 10D-6,F.A.C.AND CANNOT BE
 LOCATED IN BUILDING.
  
 A PAN AND DRAIN SHALL BE INSTALLED FOR
 THE GAS WATER HEATER PER COUNTYWIDE
 AMENDMENTS TO THE PLBG.CODE SEC.507.8.1,
 507.8.3.
  
 WATER SUPPLY CONTROL SHALL COMPLY W/SPC
 610.4.1, 610.4.2.
  
 WATER SERVICE SHALL BE EQUIPPED W/BACK-
 FLOW PREVENTION PER SPC SEC.601.
  
 VENTS SHALL NOT INCREASE IN SIZE PER
 SPC SEC.905.2(2" INCREASES TO 4")
  
 INDICATE TYPE OF GAS BEING SUPPLIED(LP
 OR NATURAL).SGC 302.
  
 GAS SUPPLY TO RANGE & CHAR-BROILER
 SHALL BE 1 1/4".
  
 WET VENTS SHALL RECEIVE DISCHARGE FROM
 FIXTURE DRAINS ONLY PER CITY OF WPB
 AMENDMENTS TO STANDARD PLBG.CODE SEC.
 911.1.
  
 AMOUNT OF PLBG.FIXTURES SHALL COMPLY W/
 FLA.STATUTE 553.141(3)(EQUAL NUMBER OF
 WATER CLOSETS FOR WOMEN AS COMBINED
 WATER CLOSETS AND URINALS FOR MEN.)

Review Stop P PLUMBING
Rev No 1 Status N Date 2000-02-29 Cont ID  
Sent By pschmitz Date 1998-12-12 Time 15:20 Rev Time 1.25
Received By tlarge Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE ATTACHED LIST.

Review Stop Z ZONING
Rev No 1 Status P Date 1998-10-22 Cont ID  
Sent By gjoyce Date 1998-10-22 Time 14:37 Rev Time 0.00
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***