Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-07-25 Cont ID  
Sent By cpuell Date 2023-07-25 Time 07:39 Rev Time 0.00
Received By cpuell Date 2023-07-25 Time 07:39 Sent To  
Notes
2023-07-25 07:42:31PLEASE PROVIDE A WARRANTY DEED SO THAT WE CAN UPDATE
 THE OWNER INFORMATION, THE OWNER ON THE APPLICATION
 FORM DOES NOT MATCH THE OWNER INFORMATION ON THE PBC
 PROPERTY APPRAISERS, IF THIS WAS A MISTAKE PLEASE
 RESUBMIT THE APPLICATION FORM WITH THE CORRECT OWNER OR
 EMAIL DEED TO [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-07-28 Cont ID  
Sent By dbattles Date 2023-07-28 Time 13:37 Rev Time 0.00
Received By dbattles Date 2023-07-28 Time 13:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-07-27 Cont ID  
Sent By lbond Date 2023-07-27 Time 14:48 Rev Time 0.00
Received By lbond Date 2023-07-27 Time 14:48 Sent To  
Notes
2023-07-27 14:52:52FBC (2020) 107.2.1.
  
 1.PROVIDE FENCE POST SECTION/FOUNDATION DETAILS AND
 FENCE MEMBERS ELEVATIONS CLEARLY DIMENSIONING OPEN
 SPACING & OVERALL HEIGHT.
 2. IF ANY EASEMENT ARE INVOLVED PLEASE PROVIDE
 CLEARENCE
  
 3. PROVIDE GATE LOCK MECHANISM DETAILS AS THIS IS A
 RESIDENTIAL POOL BARRIER MUST MEET:
  
 FBC/R BUILDING CHAPTER 45
  
  
 R4501.17.1.8
  
  
 1. ACCESS GATES, WHEN PROVIDED, SHALL BE
 SELF-CLOSING AND SHALL COMPLY WITH THE REQUIREMENTS OF
 SECTIONS R4501.17.1.1 THROUGH R4501.17.1.7 AND
 SHALL BE EQUIPPED WITH A SELF-LATCHING LOCKING DEVICE
 LOCATED ON THE POOL SIDE OF THE GATE. WHERE THE
 DEVICE RELEASE IS LOCATED NO LESS THAN 54 INCHES
 (1372 MM) FROM THE BOTTOM OF THE GATE, THE DEVICE
 RELEASE MECHANISM MAY BE LOCATED ON EITHER SIDE OF
 THE GATE AND SO PLACED THAT IT CANNOT BE REACHED BY A
 YOUNG CHILD OVER THE TOP OR THROUGH ANY OPENING OR
 GAP FROM THE OUTSIDE. GATES THAT PROVIDE ACCESS TO
 THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM THE
 POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING
 GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457
 MM) OF THE RELEASE MECHANISM
  
 R4501.17.1.9
  
 2. ALL DOORS PROVIDING DIRECT ACCESS FROM THE
 HOME TO THE POOL MUST BE EQUIPPED WITH A
 SELF-CLOSING, SELF-LATCHING DEVICE WITH
 POSITIVE MECHANICAL LATCHING/LOCKING
 INSTALLED A MINIMUM OF 54 INCHES (1372 MM)
 ABOVE THE THRESHOLD, WHICH IS APPROVED BY
 THE AUTHORITY HAVING JURISDICTION.
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By cdecoeur Date 2023-07-21 Time 07:11 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved