| 2023-07-25 08:29:59 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| | PHONE (561) 805-6656 |
| | EMAIL: [email protected] |
| | |
| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| | |
| | 1. FBC B 107.2.1. PLEASE CLARIFY; REFERENCE HAS BEEN |
| | MADE FOR TWO SEPARATE LOW SLOPE ROOF SYSTEMS; IF USING |
| | SUBMITTED MIAMI-DADE COUNTY NOA 22-0411.07 SYSTEM TYPE |
| | F (12) PLEASE INDICATE; IF USING PRODUCT APPROVAL |
| | FL1559-R15 IT HAS BEEN REVISED TO FL1559-R16. PLEASE |
| | PROVIDE THE FOLLOWING: INCLUDE COVER PAGE, EVALUATION |
| | REPORT PAGES 1-5 AND INSTALLATION INSTRUCTIONS FOR |
| | SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS |
| | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL |
| | DRAWINGS. IF USING BOTH SYSTEMS, PLEASE INDICATE ON |
| | SUBMITTED ROOF SKETCH AREAS TO RECEIVE SYSTEM TO BE |
| | USED. |
| | 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF |
| | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW |
| | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD |
| | OF PROVIDING POSITIVE DRAINAGE. |
| | 3. FBC B 1609 PROVIDE A COMPLETE SET OF SIGNED AND |
| | SEALED ENGINEERED DESIGN PRESSURE CALCULATIONS BY A |
| | FLORIDA REGISTERED PROFESSIONAL ENGINEER, REGISTERED |
| | ARCHITECT, OR REGISTERED ROOF CONSULTANT. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |