Plan Review Details - Permit 23070816
Plan Review Stops For Permit 23070816
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-07-25 Cont ID  
Sent By jbrooks Date 2023-07-25 Time 08:29 Rev Time 0.00
Received By jbrooks Date 2023-07-25 Time 07:33 Sent To  
Notes
2023-07-25 08:29:59JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1. PLEASE CLARIFY; REFERENCE HAS BEEN
 MADE FOR TWO SEPARATE LOW SLOPE ROOF SYSTEMS; IF USING
 SUBMITTED MIAMI-DADE COUNTY NOA 22-0411.07 SYSTEM TYPE
 F (12) PLEASE INDICATE; IF USING PRODUCT APPROVAL
 FL1559-R15 IT HAS BEEN REVISED TO FL1559-R16. PLEASE
 PROVIDE THE FOLLOWING: INCLUDE COVER PAGE, EVALUATION
 REPORT PAGES 1-5 AND INSTALLATION INSTRUCTIONS FOR
 SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS
 MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL
 DRAWINGS. IF USING BOTH SYSTEMS, PLEASE INDICATE ON
 SUBMITTED ROOF SKETCH AREAS TO RECEIVE SYSTEM TO BE
 USED.
 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF
 DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW
 SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD
 OF PROVIDING POSITIVE DRAINAGE.
 3. FBC B 1609 PROVIDE A COMPLETE SET OF SIGNED AND
 SEALED ENGINEERED DESIGN PRESSURE CALCULATIONS BY A
 FLORIDA REGISTERED PROFESSIONAL ENGINEER, REGISTERED
 ARCHITECT, OR REGISTERED ROOF CONSULTANT.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-25 Cont ID  
Sent By jbrooks Date 2023-07-25 Time 08:30 Rev Time 0.00
Received By jbrooks Date 2023-07-24 Time 16:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-09-26 Cont ID  
Sent By jleahy Date 2023-09-26 Time 08:19 Rev Time 0.00
Received By jleahy Date 2023-09-26 Time 08:19 Sent To  
Notes
***NONE***