Plan Review Details - Permit 23070536
Plan Review Stops For Permit 23070536
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-07-28 Cont ID  
Sent By lbond Date 2023-07-28 Time 13:29 Rev Time 0.00
Received By lbond Date 2023-07-28 Time 13:29 Sent To  
Notes
2023-07-28 13:30:22BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 23070536
  
 REVIEWED: 7.28.2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENTS:
  
 ASBESTOS PLAN REVIEW: FAILED
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 QUALIFIER, ON CONTRACTOR???S LETTERHEAD, STATING:
  
 THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-
 QUALITY/ASBESTOS-DEMOLITION-RENOVATION.HTML
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2023-07-28 Cont ID  
Sent By lbond Date 2023-07-28 Time 13:59 Rev Time 0.00
Received By lbond Date 2023-07-28 Time 13:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-07-18 Cont ID  
Sent By pleduc Date 2023-07-18 Time   Rev Time 0.00
Received By pleduc Date 2023-07-18 Time 13:23 Sent To  
Notes
2023-07-18 13:28:04FIRE PROVISO:
  
 THE HOOD AND SUPPRESSION SYSTEMS SHALL BE
 INSTALLED UNDER SEPARATE PERMIT & SHOP DRAWINGS
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-07-22 Cont ID  
Sent By ccole Date 2023-07-22 Time 14:18 Rev Time 0.00
Received By ccole Date 2023-07-22 Time 12:17 Sent To  
Notes
2023-07-22 14:20:051ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 23070536
 7/22/23
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS FG0.1 & FG1.1: SHOWS THE MEANS OF SUPPLYING
 COMBUSTION AIR TO THE COOKING APPLIANCES AND INCLUDE
 CALCULATIONS- SEC. 304.1 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-17 Time 10:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-07-22 Cont ID  
Sent By ccole Date 2023-07-22 Time 13:57 Rev Time 0.00
Received By ccole Date 2023-07-22 Time 12:17 Sent To  
Notes
2023-07-22 13:59:271ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23070536
 7/22/2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 ARCHITECTURAL REVIEW.
  
 1) SHEETS A102, A403: MISSING AND INCORRECT FBC
 ACCESSIBILITY DETAILS.
  
 A) PROVIDE THE CLEAR FLOOR SPACE DIMENSIONS FOR THE
 ACCESSIBLE WATER CLOSETS AND LAVATORIES- SEC. 604.3 &
 606.2 FBC ACC.
  
 B) SHOW THE CENTERLINES OF THE WATER CLOSETS MEASURED
 FROM THE SIDE WALLS- SEC. 604.2.
  
 C) SHOW THE HEIGHTS OF THE WATER CLOSET SEATS FROM THE
 FINISHED FLOORS- SEC. 604.4.
  
 D) SHOW THE WATER CLOSET GRAB BAR LENGTHS, AND SPACINGS
 AND EXTENSIONS FROM THE WALLS- SEC. 604.5.
  
 E) SHOW THE GRAB BAR HEIGHT MEASUREMENT TO THE TOPS OF
 THE GRIPPING SURFACES- SEC. 609.4 FBC ACC.
  
 F) SHOW THE KNEE AND TOE CLEARANCES FOR THE LAVATORIES-
 SEC. 606.2.
  
 PLUMBING REVIEW.
  
 2) P0.1: PLEASE PROVIDE A FOOD EQUIPMENT SCHEDULE AND
 FLOOR PLAN DRAWING WITH CORRELATING EQUIPMENT NUMBERS-
 SEC. 107.2.1 WPB. A COMPLETE REVIEW OF THE GREASE
 WASTE, SANITARY AND WATER DISTRIBUTION SYSTEMS CANNOT
 BE ACCOMPLISHED WITH THE INFORMATION. PLEASE NOTE WASTE
 WATER DISCHARGED FROM HAND SINKS AND FLOOR SINKS BELOW
 ICE BINS AND ICE MAKERS SHALL NOT DRAIN INTO THE GREASE
 WASTE LINE- SEC. 1003.3.1 FBC P.
  
 3) P1.1: PLEASE RE-ROUTE DRAINAGE FROM THE HAND SINK
 AND FLOOR SINKS CONVEYING ICE MAKER AND ICE BIN
 DRAINAGE FROM THE GREASE WASTE LINE TO THE SANITARY-
 SEC. 1003.3.1 WPB.
  
 4) P1.1: PROVIDE GREASE WASTE CALCULATIONS AND INDICATE
 THE CAPACITY OF THE EXISTING INTERCEPTOR- SEC. 1003.3.5
 1003.3.7 FBC P.
  
 5) P1.1: PROVIDE FLOOR CLEANOUTS FOR THE SANITARY AND
 GREASE WASTE LINES- SEC. 708.1.2 FBC P.
  
 6) P2.1: THE WATER AND FILTERED WATER DISTRIBUTION
 DRAWINGS APPEAR INCOMPLETE. PLEASE SHOW SUPPLY LINE
 RUNS TO EQUIPMENT AND LOCATIONS OF WATER HAMMERS AND
 BACKFLOW PREVENTERS WHERE REQUIRED- SEC. 604.9 & 608.3
 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-07-27 Cont ID  
Sent By dantoine Date 2023-07-27 Time 14:28 Rev Time 0.00
Received By dantoine Date 2023-07-27 Time 14:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By cibaven Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***