Plan Review Details - Permit 23070534
| Plan Review Stops For Permit 23070534 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-07-25 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-07-25 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
|
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
|
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-07-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-20 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-20 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2023-07-20 12:56:22 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | LIGHT OVER TUB CAN BE WITHIN 8' OF THE RIM OF THE TUB. | | | | | | 410.10 (D) BATHTUB AND SHOWER AREAS. | | | | | | NO PARTS OF CORD-CONNECTED LUMINAIRES, CHAIN-, CABLE-, | | | OR CORD-SUSPENDED LUMINAIRES, LIGHTING TRACK, PENDANTS, | | | OR CEILING-SUSPENDED (PADDLE) FANS SHALL BE LOCATED | | | WITHIN A ZONE MEASURED 900 MM (3 FT) HORIZONTALLY AND | | | 2.5 M (8 FT) VERTICALLY FROM THE TOP OF THE BATHTUB RIM | | | OR SHOWER STALL THRESHOLD. THIS ZONE IS ALL | | | ENCOMPASSING AND INCLUDES THE SPACE DIRECTLY OVER THE | | | TUB OR SHOWER STALL. LUMINAIRES LOCATED WITHIN THE | | | ACTUAL OUTSIDE DIMENSION OF THE BATHTUB OR SHOWER TO A | | | HEIGHT OF 2.5 M (8 FT) VERTICALLY FROM THE TOP OF THE | | | BATHTUB RIM OR SHOWER THRESHOLD SHALL BE MARKED FOR | | | DAMP LOCATIONS, OR MARKED FOR WET LOCATIONS WHERE | | | SUBJECT TO SHOWER SPRAY. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-07-18 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-26 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-26 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2023-07-26 11:53:05 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23070534 | | | | | | REVIEWED: 7.26.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-07-24 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-07-24 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-07-24 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2023-07-24 13:35:18 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED FLEX SIZE FOR KITCHEN AREA | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-07-19 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-07-19 |
Time |
07:07 |
Sent To |
|
|
| Notes |
| 2023-07-19 07:08:53 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMEND 107.3.5.3 (12) - THE PLUMBING PAGES | | | APPEAR TO BE MISSING. PLEASE SUBMIT THE PLUMBING | | | DETAILS TO INCLUDE THE RISER DIAGRAM FOR THE DWV SYSTEM | | | FOR BOTH FLOORS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-26 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-26 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-26 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-26 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|