Plan Review Details - Permit 23070294
Plan Review Stops For Permit 23070294
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-07-28 Cont ID  
Sent By jbrooks Date 2023-07-28 Time 09:32 Rev Time 0.00
Received By jbrooks Date 2023-07-28 Time 07:47 Sent To  
Notes
2023-07-28 09:32:45JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA
 21-0422.01 REQUIRES THE USE OF A FIRE BARRIER BOARD.
 PLEASE PROVIDE A COMPLETE SET OF 2020 CODE VERSION
 PRODUCT APPROVALS/NOA???S FOR THE PROPOSED FIRE BARRIER
 SYSTEM TO BE USED. INCLUDE COVER PAGE, EVALUATION
 REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED.
 ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. SECOND
 REQUEST. SUBMITTED MIAMI-DADE NOA NO. 22-0617.06 IS NOT
 APPROVED FOR USE AS A FIRE BARRIER SYSTEM IT IS
 APPROVED FOR USE AS A MULE HIDE FLAT ROOF SYSTEM.
 2. FBC B 107.2.1. CITY OF WEST PALM BEACH IS NOT
 LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 150.
 SUBMITTED MIAMI-DADE COUNTY NOA 16-0628.05 COVERS
 MULTIPLE ROOFING SYSTEMS TYPES C (1) THROUGH E (5).
 SELECT SYSTEM TYPE TO BE USED. ALL APPLICABLE DETAILS
 AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE
 PRODUCT APPROVAL DRAWINGS. GENERAL LIMITATION #7 IS
 SPECIFICALLY REFERRED TO IN THIS NOA. SUBMIT FASTENER
 DENSITY CALCULATIONS PREPARED, SIGNED AND SEALED BY A
 FLORIDA REGISTERED PROFESSIONAL ENGINEER, REGISTERED
 ARCHITECT, OR REGISTERED ROOF CONSULTANT). PLEASE NOTE
 THIS PROJECT IS LOCATED IN AN EXPOSURE C CATEGORY AREA.
 SECOND REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-07-14 Cont ID  
Sent By jbrooks Date 2023-07-14 Time 12:57 Rev Time 0.00
Received By jbrooks Date 2023-07-14 Time 08:15 Sent To  
Notes
2023-07-14 12:57:35JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA
 21-0422.01 REQUIRES THE USE OF A FIRE BARRIER BOARD.
 PLEASE PROVIDE A COMPLETE SET OF 2020 CODE VERSION
 PRODUCT APPROVALS/NOA???S FOR THE PROPOSED FIRE BARRIER
 SYSTEM TO BE USED. INCLUDE COVER PAGE, EVALUATION
 REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED.
 ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 2. FBC B 107.2.1. CITY OF WEST PALM BEACH IS NOT
 LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 150.
 SUBMITTED MIAMI-DADE COUNTY NOA 16-0628.05 COVERS
 MULTIPLE ROOFING SYSTEMS TYPES C (1) THROUGH E (5).
 SELECT SYSTEM TYPE TO BE USED. ALL APPLICABLE DETAILS
 AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE
 PRODUCT APPROVAL DRAWINGS. GENERAL LIMITATION #7 IS
 SPECIFICALLY REFERRED TO IN THIS NOA. SUBMIT FASTENER
 DENSITY CALCULATIONS PREPARED, SIGNED AND SEALED BY A
 FLORIDA REGISTERED PROFESSIONAL ENGINEER, REGISTERED
 ARCHITECT, OR REGISTERED ROOF CONSULTANT). PLEASE NOTE
 THIS PROJECT IS LOCATED IN AN EXPOSURE C CATEGORY AREA.
 3. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF
 DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING
 CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S),
 MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW
 POSITIVE DRAINAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-28 Time 13:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-07-28 Cont ID  
Sent By jbrooks Date 2023-07-28 Time 09:32 Rev Time 0.00
Received By jbrooks Date 2023-07-25 Time 08:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-14 Cont ID  
Sent By jbrooks Date 2023-07-14 Time 12:57 Rev Time 0.00
Received By jbrooks Date 2023-07-13 Time 11:29 Sent To  
Notes