Plan Review Details - Permit 23070238
Plan Review Stops For Permit 23070238
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-07-14 Cont ID  
Sent By cpuell Date 2023-07-14 Time 09:41 Rev Time 0.00
Received By cpuell Date 2023-07-14 Time 09:41 Sent To  
Notes
2023-07-14 09:41:33SUITE 135 IS NOT A RECOGNIZED SUITE NUMBER, PLEASE
 PROVIDE A FLOOR PLAN SHOWING EVERY SUITE ON THAT FLOOR.
 PLEASE EMAIL TO [email protected] FOR FURTHER
 QUESTIONS YOU CAN ALSO CALL 561-805-6659

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2023-07-18 Cont ID  
Sent By jwitmer Date 2023-07-18 Time 14:30 Rev Time 0.00
Received By jwitmer Date 2023-07-18 Time 14:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2023-07-18 Cont ID  
Sent By jwitmer Date 2023-07-18 Time 14:43 Rev Time 0.00
Received By jwitmer Date 2023-07-18 Time 14:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-07-15 Cont ID  
Sent By jleahy Date 2023-07-15 Time 09:16 Rev Time 0.00
Received By jleahy Date 2023-07-14 Time 17:54 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2023-07-15 Cont ID  
Sent By jleahy Date 2023-07-15 Time 09:20 Rev Time 0.00
Received By jleahy Date 2023-07-15 Time 09:19 Sent To  
Notes
2023-07-15 09:20:53LOW VOLTAGE VOICE AND DATA AS PRER PLAN..

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-07-14 Cont ID  
Sent By clfranci Date 2023-07-14 Time   Rev Time 0.00
Received By clfranci Date 2023-07-14 Time   Sent To  
Notes
2023-07-14 11:13:23THIS PLAN WAS REVIEWED AND APPROVED BY CAITLIN L
 FRANCIS, FIRE INVESTIGATOR, WITH THE FOLLOWING
 COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING/WALL
 AREAS MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE
 FIRE SPRINKLER AND FIRE ALARM SYSTEMS FOR CODE COVERAGE
 AND COMPLIANCE BY CERTIFIED CONTRACTORS.
  
 2) ANY AND ALL WORK ON THE FIRE SPRINKLER AND/OR FIRE
 ALARM SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS AND
 SHOP DRAWINGS BY CERTIFIED CONTRACTORS.
  
 3) THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL
 REMAIN ACTIVE THROUGHOUT THE DEMO AND CONSTRUCTION
 PERIODS.
  
  
 CAITLIN L FRANCIS
 FIRE INVESTIGATOR
 WEST PALM BEACH FIRE RESCUE
 561.804.4728
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-21 Cont ID  
Sent By cmontell Date 2023-07-21 Time 13:33 Rev Time 0.00
Received By cmontell Date 2023-07-21 Time 13:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-07-21 Cont ID  
Sent By cmontell Date 2023-07-21 Time 13:32 Rev Time 0.00
Received By cmontell Date 2023-07-21 Time 13:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-07-15 Cont ID  
Sent By ccole Date 2023-07-15 Time 09:52 Rev Time 0.00
Received By ccole Date 2023-07-15 Time 09:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-07-15 Cont ID  
Sent By jleahy Date 2023-07-15 Time 09:17 Rev Time 0.00
Received By jleahy Date 2023-07-15 Time 09:17 Sent To  
Notes
***NONE***