| 2023-07-25 16:43:08 | WEST PALM BEACH DEVELOPMENT SERVICES |
| | BUILDING DIVISION |
| | 2020 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 23070139 |
| | ADD: 424 PARK PL # 103 |
| | CONT: APADANA GROUP INC. |
| | TEL: 561-348-4805 |
| | E-MAIL: [email protected] |
| | |
| | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. JULY 25TH/ 23 |
| | ACTION: DENIED |
| | |
| | 1) SHEET G1.0 HEADING OF USE AND OCCUPANCY STATES THE |
| | OCCUPANCY AS BUSINESS AND REFERENCES PER SECTION |
| | 303.1.1 SMALL OCCUPANCIES SHALL BE CLASSIFIED AS |
| | BUSINESS LESS THAN 50 OCCUPANTS. PLEASE UNDERSTAND |
| | SECTION 303.1.1 IS WITHIN THE ASSEMBLY OCCUPANCIES AND |
| | IF IT IS AN ASSEMBLY OCCUPANCY SUCH AS RESTAURANTS, |
| | TAVERNS AND BARS WITH A OCCUPANT LOAD OF LESS THAN 50 |
| | THEN THEY ARE CONSIDERED SMALL ASSEMBLY OR BUSINESS |
| | OCCUPANCY. BUSINESS OCCUPANCIES ARE USUALLY OFFICES |
| | WHERE PROFESSIONALS SUCH AS DOCTORS, LAWYERS, CIVIC |
| | ADMINISTRATION, RADIO STATIONS OR SERVICE-TYPE |
| | TRANSACTIONS, INCLUDING BANKS INCLUDING STORAGE OF |
| | RECORDS AND OR ACCOUNTS. THE PLAN IS NOT CLEAR AS TO |
| | THE USAGE OF THIS SPACE? THERE IS NO DESK FOR A |
| | BUSINESS OCCUPANCY POSSIBLE MERCANTILE? PER SECTION |
| | 309.1 2020 FBC-BUILDING CODE DISPLAYS AND SALES OF |
| | MERCHANDISE ACCESSIBLE O THE PUBLIC. |
| | |
| | 2) THE OCCUPANT LOAD WOULD BE A HIGHER COUNT SINCE AN |
| | OCCUPANT LOAD FACTOR OF 60 WOULD BE USED INSTEAD OF THE |
| | 150 FOR BUSINESS. TABLE 1004.5 2020 FBC-BUILDING. |
| | PLEASE PROVIDE OCCUPANCY TYPE AND OCCUPANT LOAD. |
| | |
| | 3) SHEET LS-1.0 STATES A BUSINESS OCCUPANCY BUT ROOM |
| | LABELED 01 IS STATED AS A SHOWROOM WHICH LENDS ITSELF |
| | TO A MERCANTILE OCCUPANCY AS IN THE 2020 FBC-BUILDING |
| | CODE SECTION 309.1 DISPLAYS AND SALES OF MERCHANDISE. |
| | |
| | 4) THE LS-1.0 SHEET STATES COMMON PATH OF TRAVEL IS 84 |
| | FEET 9 INCHES FOR A BUSINESS OCCUPANCY AND OCCUPANT |
| | LOAD OF 30 OR LESS YOU WERE OK, BUT FOR A MERCANTILE |
| | OCCUPANCY 1706/ 60= 29 +2 STORAGE = 31 OCCUPANTS TABLE |
| | 1006.2.1 ONLY ALLOWS 75 FEET MAXIMUM COMMON PATH OF |
| | TRAVEL, EVEN IF FIRE SPRINKLERED BUILDINGS. |
| | |
| | 5) SHEET A2.1 INDICATES NEW ROOF TOP UNIT AND CURB, |
| | SHEET M701 STATES NEW ROOF FRAMING BY STRUCTURAL |
| | ENGINEER. 2020 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON |
| | STRUCTURAL MEMBERS AND THEIR CONNECTIONS SHALL BE |
| | DETERMINED BY METHODS OF STRUCTURAL ANALYSIS THAT TAKE |
| | INTO ACCOUNT EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC |
| | COMPATIBILITY AND BOTH SHORT- AND LONG-TERM MATERIAL |
| | PROPERTIES. EVERY STRUCTURE SHALL BE DESIGNED TO RESIST |
| | THE OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES |
| | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND |
| | LOADS. |
| | |
| | THE ROOF TOP A/C STAND PRODUCT APPROVALS, TO BE |
| | REVIEWED BY THE DESIGNER OF RECORD. PLEASE IDENTIFY THE |
| | FOLLOWING REQUIREMENTS CALCULATING THE AREA (SIDE VIEW) |
| | OF THE ROOF TOP COMPRESSORS, CONFIGURATION ON STAND, |
| | THE MEAN ROOF HEIGHT OF THE STAND AND COMPRESSORS, |
| | WEIGHT, CIRCLED THE DESIGN PARAMETERS IN THE TABLES, |
| | ANCHORS AND UPLIFT VERSES MOMENT FOR THE UNIT TO THE |
| | STAND AND THE STAND TO THE ROOF. THE PRODUCT APPROVAL |
| | IS TO BE REVIEWED BY THE DESIGNER OF RECORD, APPROVED |
| | BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. |
| | |
| | 6) COMPONENTS & CLADDING. PLEASE SUBMIT THE COMPONENTS |
| | AND CLADDING PRODUCT APPROVALS. 1609.6.4.4.1 COMPONENTS |
| | & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, |
| | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ |
| | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, ROOF |
| | REPAIRS |
| | |
| | 7) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE |
| | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP |
| | DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD |
| | PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC. |
| | |
| | 8) SHEET A3.0 INTERIOR ELEVATIONS DOES NOT PROVIDE |
| | INTERIOR WALL FINISHES FOR THE RESTROOM NOR SERVICE |
| | SINKS. 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS |
| | COMMENT IS A RESULT OF THE BUILDING OFFICIAL |
| | INTERPRETATION ON 06/2020. IN BATHROOMS, RESTROOMS & |
| | SERVICE SINK AREAS EPOXY PAINT IS NO LONGER CONSIDERED |
| | A SMOOTH HARD, NON-ABSORBENT SURFACE. |
| | |
| | 8A) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF |
| | SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A |
| | SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT |
| | LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL |
| | ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A |
| | TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. |
| | |
| | 9) SHEET A3.0 DETAIL 2 WALL MIRROR OVER THE LAVATORY NO |
| | HEIGHT IS GIVEN, HEIGHT OF THE MIRRORS FROM THE |
| | FINISHED FLOORS TO THE BOTTOM EDGE OF THE REFLECTIVE |
| | SURFACE, MIRRORS ABOVE SINKS. SECTION 606.3 2020 |
| | FBC-ACCESS CODE. |
| | |
| | 10) SHEET A4.0 INTERIOR WINDOW WALL SYSTEM NO MENTION |
| | OF TYPE OF GLAZING WHEN GLASS IS IN HAZARDOUS LOCATIONS |
| | 2406.4 2020 FBC-BUILDING CODE TABLE 2406.2(1). |
| | |
| | 11) SHEET A4.1 LOADED WRONG BLACK SCREEN. 2020 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1, ADMINISTRATION 107.2.1. CONSTRUCTION |
| | DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE |
| | LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND |
| | SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS |
| | OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND |
| | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 12) A TRANSMITTAL LETTER / NARRATIVE LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| | REVIEW, SUBSEQUENT |
| | REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE. |
| | |
| | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| | PART-TIME/ SEMI-RETIRED. |
| | |
| | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| | BACK INTO THE OFFICE CALL |
| | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| | THANK YOU. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |