| 2023-07-07 08:37:21 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| | PHONE (561) 805-6656 |
| | EMAIL: [email protected] |
| | |
| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| | |
| | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL |
| | FL27499-R4 IS INCOMPLETE, PROVIDE THE FOLLOWING |
| | ADDITIONAL INFORMATION: COVER SHEET |
| | (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE |
| | VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL |
| | INFORMATION ABOUT THE PRODUCT). |
| | 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R37 |
| | HAS BEEN REVISED TO FL5259-R39. PLEASE PROVIDE A |
| | COMPLETE SET TO INCLUDE COVER PAGE(S); IT COVERS |
| | MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS; ALLOWABLE |
| | UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, ALLOWABLE |
| | SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT OPTIONS |
| | FROM EACH CATEGORY TO BE USED; SELECT FROM TABLE 4A |
| | DIRECT-TO-DECK UNDERLAYMENT IN TILE ROOF APPLICATIONS |
| | OR TABLE 4B 2-PLY UNDERLAYMENT SYSTEMS IN TILE ROOF |
| | APPLICATIONS. ALL APPLICABLE DETAILS AND ATTACHMENTS |
| | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL |
| | DRAWINGS. |
| | 3. FBC B 107.2.1 PLEASE NOTE: PRODUCT APPROVAL |
| | FL5259-R39 (NON-HVHZ) TABLES 4A & 4B, ALLOWABLE DESIGN |
| | PRESSURE UNDERLAYMENT CHARTS ARE REQUIRED FOR USE IN |
| | ROOF TILE APPLICATIONS ONLY. |
| | 4. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF |
| | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING |
| | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), |
| | MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW |
| | POSITIVE DRAINAGE. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |