| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| | |
| | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| | APPROVAL FL10884-R7 SOLAR POWERED ROOF VENT MAXIMUM |
| | DESIGN PRESSURE -82.5 PSF. DO NOT MEET THE MINIMUM ZONE |
| | 2R DESIGN PRESSURE REQUIREMENT OF -102 FOR EXPOSURE |
| | CATEGORY C AREAS WITH A GABLE ROOF; ROOF SLOPES |
| | 2/12-4/12 MEAN ROOF HEIGHT UP TO 15 FT. SELECT A |
| | PRODUCT APPROVAL WITH A SYSTEM THAT MEETS OR EXCEEDS |
| | THIS REQUIREMENT. ALL APPLICABLE DETAILS AND |
| | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT |
| | APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT |
| | SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED |
| | SITE-SPECIFIC ENGINEERING. |
| | 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL |
| | FL9777-R17HAS BEEN REVISED TO FL9777-R18. PLEASE |
| | PROVIDE A COMPLETE SET TO INCLUDE COVER PAGES; IT |
| | COVERS MULTIPLE PRODUCTS & INSTALLATION METHODS. SELECT |
| | PRODUCT & INSTALLATION METHOD TO BE USED. ALL |
| | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY |
| | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |