Plan Review Details - Permit 23061394
Plan Review Stops For Permit 23061394
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-07-21 Cont ID  
Sent By pvalenti Date 2023-07-21 Time 13:29 Rev Time 0.00
Received By pvalenti Date 2023-07-21 Time 13:05 Sent To  
Notes
2023-07-21 13:46:10PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) CITY OF WPB AMENDMENTS TO FBC B 107.2.1, THE
 SUBMITTED DOCUMENT "SCAFFOLDING PLAN" ARE NOT CLEAR AS
 TO THE EXTENT AND SPECIFIC LOCATION OF WORK AREA.
  
 2.) CITY OF WPB AMENDMENTS TO FBC B 107.2.1, THE
 SUBMITTED DOCUMENTS ARE NOT LEGIBLE.
  
 3.) THE DOCUMENTS SUBMITTED NEED TO HAVE THE DESIGN
 PROFESSIONAL'S SIGNATURE 3RD PARTY VERIFIED:
 A.) DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE. A SCAN OF A WET SEAL AND
 SIGNATURE OR DIGITAL SIGNATURE IS NOT CONSIDERED A
 VALID DIGITAL SIGNATURE.
 ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR
 ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH
 61G1-16 AND 61G15, F.A.C.
 B.) SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT.
 481, F.S. & 61G1.
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-07-18 Cont ID  
Sent By cseifer Date 2023-07-18 Time 15:27 Rev Time 0.00
Received By cseifer Date 2023-07-18 Time 15:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-07-12 Cont ID  
Sent By pleduc Date 2023-07-12 Time   Rev Time 0.00
Received By pleduc Date 2023-07-12 Time 16:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-11 Time 13:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-07-21 Cont ID  
Sent By pvalenti Date 2023-07-21 Time 13:21 Rev Time 0.00
Received By pvalenti Date 2023-07-21 Time 13:06 Sent To  
Notes
2023-07-21 13:28:17SIGNATURE REVIEW DENIED:
  
 THE SUBMITTED PLAN SHEET (S-3) WITH TITLE BLOCK FROM
 DESIGN PROFESSIONAL "EDUARDO J. CANTO P.E." NEEDS TO BE
 DIGITALLY SIGNED/SEALED WITH A THIRD PARTY
 VERIFICATION.
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD A DIGITALLY SIGNED (THIRD PARTY VERIFIED) PLAN:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By cibaven Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy